The product is a manual device to clean dental instruments used to
remove the coarse parts of cements, alginates, etc. before the
subsequent cleaning treatments of the sterilization cycle.ODOTTO
Dimensions
H=117mm D=122 mm
Weight
0,8 Kg
Packaging dimensions
140X134X123 mm
During the cleaning step is necessary to use a detergent
cleaning tools; the tested solvent we recommend to use is
ORANGE SOLVENT, it isn't however exclude the use of other
types of detergents or disinfectants.
To use the device correctly start by pulling out the plastic cap (POS.A). Fill
the container in the circular ring about half way up (POS.B). Pour the
detergent on the brush (POS.C). Take the tools that need to be cleaned
and start brushing them, making coordinated circular up-and-down
movements and vice versa (pay attention to excessive splashes of solvent
when going up). At this stage, each cleaned tool can be placed in the
circular ring at the stand-by stage.
After cleaning the tools you can proceed with the treatments below, part of
the sterilization cycle. Finish by emptying the device and start the full
cleaning stage.
To use the device you must wear suitable protective devices:
- protective gloves;
- suitable protective eyewear;
- suitable protective clothing.
The device is classified as dangerous sanitary waste with the risk of
infection, so the management of disposal of such waste must be carries
out in accordance with regulations
in force in the country where the device is used.
Adequate disposal of equipment no longer used prevents negative
effects on the environment and human health.
Wear suitable protective clothing. Avoid contact and inhalation
of vapors of the solvent inside. Keep in a cool and dry place.
Keep away from heat sources and direct exposure to light.
Make sure it is firmly closed after using it.
For routine cleaning and maintenance of the device please refer to basic
hygiene standard envisaged for these circumstances. The appliance
must be cleaned thoroughly each time it is used.
To clean the device properly, simply follow the steps below with reference
to fig.3:
- Remove the plastic cap (Pos.2), remove the rubber plug (pos.4) and
remove the brush (Pos. 3);
- Carry out a cold disinfection of parts by using disinfectants;
FIG. 2
- Pour some isopropyl alcohol on a dry cloth and continue cleaning only
the inside of the glass (Pos.1);
- Reassemble the whole device.
THE DEVICE IS NOT AUTOCLAVABLE
Description
GLASS
COVER
BRUSH
RUBBER COVER
MANUAL
FIG. 3
Code
1SSCA0006
1SSCA0007
1SSCA0004
1SSCA0005
0SSCI0002
Need help?
Do you have a question about the CLEAN 2070S and is the answer not in the manual?
Questions and answers