TOWN WOK RANGES ARE CUSTOM / MADE TO ORDER. THIS DOCUMENT DOES NOT ADDRESS ALL OPTIONS/ACCESSORIES
POSSIBLE. MAINTENANCE IS TO BE PERFORMED BY A QUALIFIED PERSON FAMILIAR WITH THE SUBJECT EQUIPMENT AND
HAZARDS INVOLVED. THIS DOCUMENT DOES NOT CLAIM TO COVER ALL POSSIBLE SCENARIOS OR ISSUES THAT MAY BE
ENCOUNTERED. THE DOCUMENT IS INFORMATIONAL ONLY. IT DOES NOT RELIEVE THE QUALIFIED PERSON FROM
EXERCISING GOOD JUDGEMENT.
Chamber insulation & chamber rings - This section should be evaluated by restaurant personnel daily to prevent
accelerated degradation of the range. Damaged items must be replaced as soon as possible.
maintenance is not covered under warranty!
o York/EcoDeck ceramic sleeves: Replace if cracked or otherwise deteriorated.
o Masterrange brick: Replace missing or cracked mortar and bricks.
o Verify cast iron wok rings are not cracked or otherwise broken. Replace as needed.
o If rings are fully intact, clean and degrease the wok rings and areas around it.
o Clean the stainless steel top deck around the wok ring. Remove any grease and debris.
o EcoDeck units: Clean the welded return ring directly underneath the wok ring.
Stainless steel exterior and parts
o Clean and maintain stainless steel using appropriate cleaning methods and products. Do not use harsh
abrasives and clean in the direction of the grain.
o Tighten the (6) button head screws holding the 3-pipe wok rack. Use Loctite to further prevent loosening.
Gas train & valves
o Check for bent valve shafts & replace as needed.
o Tighten loose valve handles or replace as needed.
o If the valve has or is close to being in use for a year, apply a new coating of high temperature valve grease.
o Check for gas leaks around valve area and unions with a sniffer or bubble solution.
Pilot Safety System (if applicable)
o Light all pilots and check for proper operation. Cycle burners on/off and verify the pilot stays lit.
o Ensure pilot and thermocouple are mounted properly.
o Verify that the pilot flame is enveloping the top 3/8" to ½" of the thermocouple.
o Check the thermocouple connection at the safety valve. Make sure it's tight and corrosion free.
o Replace pilots, thermocouples and safety heads as needed.
E/M/Y SERIES WOK RANGE
ROUTINE MAINTENANCE GUIDE
Damage caused by lack of
9-2021