Tecnogas 11940 Operation Manual

Tecnogas 11940 Operation Manual

Condensate pump
Hide thumbs Also See for 11940:

Advertisement

Quick Links

Pompa di Scarico Condensa
Condensate Pump
M
O
|
O
M
anuale
perativO
peratiOn
anual
SKU 11940
SKU 11942
SKU 11945

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 11940 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tecnogas 11940

  • Page 1 Pompa di Scarico Condensa Condensate Pump anuale perativO peratiOn anual SKU 11940 SKU 11942 SKU 11945...
  • Page 2 Al fine di non invalidare la garanzia, consigliamo di affidarsi a installatori e manutentori esperti. Thank you for buying this Tecnogas product. For your safety, please read these instructions carefully before use. In order not to avoid guarantee, we strongly recommend to rely on expert technicians and service.
  • Page 3: Informazioni Sulla Sicurezza

    Always ensure the metal magnet in the float is facing upward. Always ensure the reservoir is sitting flat and horizontal. Per ogni dubbio contattate il nostro servizio clienti. Please contact our costumer service for any concerns. TECNOGAS manuale operativo operation manual...
  • Page 4: Pump Components

    Water tank cover Sfiato Blow hole Coperchio serbatoio Tank lid Cavo del sensore Sensor cable Tubo di collegamento Connecting pipe SKU 11940 - 11942 Copertura della pompa Pump cover Cavo di collegamento 6-pin socket (6 poli) SKU 11945 Descrizione Description...
  • Page 5: Performance Graphs

    SKU 11942 Mounting plate SKU 11945 Piastra di montaggio Mounting plate Grafici delle prestazioni Performance Graphs SKU 11945 SKU 11940 - 11942 Lunghezza scarico | Head lenght Lunghezza scarico | Head lenght SKU 11942 SKU 11940 TECNOGAS manuale operativo operation manual...
  • Page 6: Technical Specifications

    With all the complain, the costumer must attach a detailed description of the defect. Complain about wrong mounted or non-maintanced product will NOT be accepted. TECNOGAS manuale operativo operation manual...
  • Page 7: Installazione

    If the pump can’t work normally, the system will be cut automatically. Please contact the qualified person to maintain it. L: Fase (Marrone) L: Fire Wire (Brown) N: Neutro (Blue) N: Zero Line (Blue) NC: Normalmente Chiuso (Nero) NC: Normally Closed (Black) COM: Linea Comune (Nero) COM: Common Line (Black) TECNOGAS manuale operativo operation manual...
  • Page 8 SKU 11940 - 11942 Assicurarsi che il galleggiante sia posizionato nel serbatoio con il magnete rivolto verso l’alto. Make sure the float is in the tank with the magnet on the upper side. Controllare che il filtro sia posizionato correttamente e che il coperchio sia in posizione.
  • Page 9 If the circuit is set up as the following scheme, the pump can switch off the air conditioner when any problems occur to the draining device. Testare il funzionamento della pompa riempiendo manualmente il serbatoio. Verificare eventuali perdite. Test pump operation by pouring water into the tank. Verify the presence of leaks. TECNOGAS manuale operativo operation manual...
  • Page 10: Risoluzione Problemi

    La pompa non è installata perfettamente in Riposizionare correttamente la pom- posizione orizzontale. pa e controllare il livello dell’acqua. The installation of the pump is not Adjust the tank and check the water horizontal. level. TECNOGAS manuale operativo operation manual...
  • Page 11 Altri prodotti TECNOGAS Other TECNOGAS product ATTREZZATURE PER VUOTO E/O CARICO ATTREZZATURE – UTENSILI VACUUM AND CHARGE EQUIPMENTS EQUIPMENTS – TOOLS RIVELATORI PERDITE E STRUMENTI DI MISURA LAVAGGIO E SANIFICAZIONE IMPIANTI LEAKS DETECTORS AND MEASURE INSTRUMENTS WASHING AND SANITIZATING SYSTEM...