Manufacturer Declaration TA-Luft Technical data Manufacturer: Face to face: DIN EN 558-1, basic series 1 (ISO 5752 basic series 1) Richter Chemie-Technik GmbH optionally face to face acc. to specifications Otto-Schott-Str. 2 D-47906 Kempen Materials : Telephone: +49 (0) 2152 146-0...
Series SGS/F Page 3 Weight: 1.2 Tightening torques Nom. 15 20 25 32 80 100 All screws greased, tighten in diametrically size opposite sequence! approx. The tightening torques for pipe screws and cylindrical glass screws mentioned must not be exceeded. For Installation position : an exception, see Section 8.
It must be read before installation and commissioning! Richter sight glasses of the series SGS/F are For valves which are used in potentially explosive pressure relief components in accordance with the areas, see Section 3.
Series SGS/F Page 5 For the customer / operator Improper operation When using the cylindrical sight glass, it must be The operational reliability of the cylindrical sight glass ensured that supplied is only guaranteed if it is used properly in accordance with Section 2.1 of this operating manual.
Series SGS/F Page 6 No hazardous charges can occur as charges are ♦ If the valve is heated (e.g. heating jacket), it must discharged direct via the lining and shell (surface be ensured that the temperature classes pre- resistance < 10 Ohm, leakage resistance <...
These gaskets are The test pressure PT of a valve must not exceed the available as special accessories in the Richter range. value of 1.5 x PS(PN) as per the identification of the valve.
Series SGS/F Page 8 Shutdown Prior to starting any repair work, the valve is The local regulations are to be observed when to be thoroughly cleaned. Medium residue dismantling the valve. may be in the valve even if it has been properly drained and flushed.
Page 14
Waste Management Law (AbfG) and the Water Resources Act (WHG) An inspection/repair of Richter products and parts will only take place, if the attached explanation is filled out cor- rectly and completely by authorized and qualified technical personnel and is available.
Page 15
Safety Information / Declaration of No Objection Concerning the Contamination of Richter-Pumps, -Valves and Components SCOPE AND PURPOSE Each entrepreneur (operator) carries the responsibility for the health and safety of his employees. This extends also to the personnel, who implements repairs with the operator or with the contractor.
Page 16
for credit note Phone : Fax : End user : A. Details of Richter-product: Failure description: Classification: Article number: Serial number: B. Condition of the Richter- product: Contamination : Was it in operation ? toxic ...