Operating Manual for Digital Quick-Response Thermometer
GTH 1200 / GTH 1200 A

Specification:

Range:
Resolution:
Accuracy:
Analog output (GTH 1200A): 1mV/°C
Probe connection:
Probe:
Display:
Working temperature:
Nominal temperature:
Power supply:
Battery service life:
Low battery warning:
Dimensions:
Weight:
Other:
GKK 1100:
GKK 1200:
GB 9V:
GNG 10:
Electromagnetic
compatibility:
GREISINGER
D - 93128 Regenstauf, Hans-Sachs-Straße 26
Tel.: 09402 / 8500 od. 8748, Fax: 09402 / 1829
range 1: -65.0 to +199.9°C
range 2: -65 to +1150°C
0.1°C from -65.0 to +199.9°C (switch pos. 1)
1°C from -65 to +1150°C (switch pos. 2)
better than 0.2 % ± 0.5°C respectively ± 1 digit
standard flat mono plug
NiCr-Ni, acc. to ½ DIN 43710 for plug-in operation (not included in scope of supply !)
3 1/2 digit LCD, approx. 13 mm high
0 to 45°C
25°C
9V battery, type IEC 6 F 22 (included)
GTH 1200 A: additional mains power connector for mono plug 2.5 mm diameter
(automatic battery disconnection)
approx. 100 operating hours
"BAT"
approx. 150 x 86 x 30 mm (H x W x D) impact resistant
ABS plastic housing, with integrated pop-up clip for table top or suspended use, lateral
holders for probe handle
approx. 235g (incl. battery)
approx. 20 different standard NiCr-Ni temperature probes available (with double-accuracy
as compared to DIN standards). Please refer to list of probes!
suitable case with foame lining
suitable case with punched lining for this unit, 3 probes with handle, spare battery etc.
spare 9V battery, type IEC 6 F 22
power supply
In accordance with EN50081-1 and EN50082-2 for unrestricted use in housing and
industrial areas. Additional error: <0.5%
H04.0.03-6-e
electronic GmbH
Blatt 1 von 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GTH 1200 and is the answer not in the manual?

Questions and answers

Summary of Contents for GREISINGER electronic GTH 1200

  • Page 1 0 to 45°C Nominal temperature: 25°C Power supply: 9V battery, type IEC 6 F 22 (included) GTH 1200 A: additional mains power connector for mono plug 2.5 mm diameter (automatic battery disconnection) Battery service life: approx. 100 operating hours Low battery warning: "BAT"...
  • Page 2 H04.0.03-6-e Blatt 2 von 2 Points to be observed during operation a.) Make sure to apply correct operating voltage as low or damaged battery will lead to measuring inaccuracies . Immediately after "BAT" is displayed, battery needs to be replaced b.) Make sure to maintain unit properly and to operate it in accordance with the specification listed (do not throw, knock etc.).

This manual is also suitable for:

Gth 1200 a

Table of Contents