Simplified Ultraviolet Sterilization High Output Ultraviolet Sterilization System Installation Instructions & Owner’s Manual PL PLI AN ANT...
Page 2
WA R N I N G ! Read and understand product manual completely before use, installation or service. Failure to follow all guidelines could cause personal injury or property damage. UV Radiation is harmful to eyes and skin. DO NOT look at UV lamp when turned on without safety goggles.
Warning: This product may contain chemicals known to the State of California to cause is protected by a Ground Fault Circuit Interrupter (GFCI). cancer and birth defects or other reproductive harm. POLARIS SCIENTIFIC ULTRAVIOLET P.O. Box 2235 Chino Hills, CA 91709 •...
Proper pre-treatment is ground the plug into an appropriate outlet that is properly installed essential for the UV disinfection system to operate as intended. and grounded in accordance with all local codes and ordinances. Models: UVA-418HO UVA-630HO UVA-946HO...
China Patent: ZL 2015 2 0160464.9, Mexico Patent: 49882 Aluminum Chamber Clip CLP-35UV Use on all systems Polaris Scientific UV and the Polaris Scientific UV logo design are registered Trademarks in the United States and certain Plastic Plug UV-PLUG Use on all systems other countries.
The UV system should be the last off-line, water must be boiled for 20 minutes prior to consumption. treatment the water receives before it reaches the faucet. Models: UVA-418HO UVA-630HO UVA-946HO...
Page 8
(typically a space equal to the size of AND HORIZONTAL INSTALLATION the chamber is appropriate). (Figure 4) Unit overall length Min. clearance equal to unit overall length POLARIS SCIENTIFIC ULTRAVIOLET P.O. Box 2235 Chino Hills, CA 91709 •...
Page 9
NOTE: DO NOT solder connections while attached on. To remedy this, run a cold water tap anywhere in to the system, this could damage the O-ring seals. the house for a minute to flush out the warm water. Models: UVA-418HO UVA-630HO UVA-946HO...
10 seconds until - Push and twist the ballast you hear an audible tone - Attach the connector to cup against nut to secure and LED display will read the new lamp. the connection. once again 0365 Models: UVA-418HO UVA-630HO UVA-946HO...
Note: Tight by hand only. DO NOT over tight. NOTE: - After replacing the UV lamp or quartz sleeve perform the disinfection procedure, refer to Section 3.2. POLARIS SCIENTIFIC ULTRAVIOLET P.O. Box 2235 Chino Hills, CA 91709 •...
(1 second on, 1 second off) and the red indicator lights can only be silenced by changing the UV lamp and intermittently. The system will remain in this state, manually resetting the ballast controller timer. until this condition is remedied. Models: UVA-418HO UVA-630HO UVA-946HO...
Lamp life expired - countdown is at “0" days. Refer to Section 5.2. DISPLAY FAULT MODE LED display reads “A3" Press reset button for a deferred alarm, replace UV lamp. POLARIS SCIENTIFIC ULTRAVIOLET P.O. Box 2235 Chino Hills, CA 91709 •...
Connect Fittings, Polaris Scientific Ultraviolet, Hydron Membranes, Aquatrol, Shok Blok, HydroGuard, must be signed "not examined". The Seller shall have the right to inspect the goods at the Buyer’s premises Hydronix Water Technology, any of its subsidiaries and its authorized distributors.
Page 17
Agreement may be brought by the Buyer more than two (2) years after LIABILITY. IN NO EVENT SHALL THE SELLER BE LIABLE TO THE BUYER OR ANY OTHER ENTITY FOR MORE such cause of action accrues. Models: UVA-418HO UVA-630HO UVA-946HO...
Page 18
NOTES POLARIS SCIENTIFIC ULTRAVIOLET P.O. Box 2235 Chino Hills, CA 91709 •...