FAR electronic controller art. 9611 is suitable for heating systems with 3-point mixing valve and is preset for fixed point
operation, or with temperature compensation dependant on the external temperature. Each electronic controller can
control one 3-point mixing valve and can be connected to one flow sensor and /or one outside sensor.
Front panel description:
DISPLAY:
Valves opening Mix.
Valves closing Mix.
Pump starting.
Communication ok
The presence of an arrow next to a symbol
indicates that the function is active.
FUNCTION BUTTON:
Select a value to modify.
OK
Confirm the value modified.
Reset controller.
The electronic controller art. 9611 permits control of a mixing valve and a pump in relation to the mixed circuit of a
heating system.
It is supplied pre-programmed and it can operate at a fixed point with delivery probe only or with temperature
modulation, if both supply probe and external probe are connected.
Before putting the product into service it will be necessary to set the values relating to the desired functions.
FAR ELECTRONIC CONTROLLER
Art. 9611
SIMPLIFIED USER MANUAL
The package includes:
N°1
N°1
N°1
N°1
N°1
N°1
Instruction manual
control unit
electrical connections support
supply temperature probe
assembly kit in contact with supply probe
outside temperature sensor
seat for Ø6 mm probe
MAIN SELECTOR:
Switched off regulation (anti-freeze only).
Automatic function.
Fixed point: not provided.
With external probe: nominal room T .
Fixed point: system supply T.
With external probe:max supply T.
Not provided
Fixed point: not provided.
With external probe: heating curve
Mixing valve dynamics.
BUS address.
Manual operation /test.
INCREMENTAL SELECTOR:
Changes parameter value.
+ -
Increase.
Decrease.