Download Print this page
AquaSure Quantum UV Owner's Manual
AquaSure Quantum UV Owner's Manual

AquaSure Quantum UV Owner's Manual

Whole house ultra violet uv water purifier system

Advertisement

Available languages

Available languages

Quick Links

MKT-M-1001 • 06/22
WHOLE HOUSE ULTRA VIOLET
(UV) WATER PURIFIER SYSTEM
SYSTÈME POLYVALENT DE
FILTRATION D'EAU SOUS ÉVIER
LE MANUEL DU PROPRIÉTAIRE
For optimum performance and protection
against contaminants, please thoroughly
read this owner's manual before
proceeding with the installation.
Pour une performance optimale et une
protection contre l'eau dure, veuillez lire
entièrement ce manuel d'utilisation avant de
procéder à l'installation.
© 2022 Aquasure USA - All Rights Reserved

Advertisement

loading
Need help?

Need help?

Do you have a question about the Quantum UV and is the answer not in the manual?

Questions and answers

Summary of Contents for AquaSure Quantum UV

  • Page 1 Pour une performance optimale et une protection contre l’eau dure, veuillez lire entièrement ce manuel d’utilisation avant de procéder à l’installation. MKT-M-1001 • 06/22 © 2022 Aquasure USA - All Rights Reserved...
  • Page 2 WELCOME & CONGRATULATIONS Thank you for choosing Aquasure. This owner’s manual will guide you through the necessary steps to install your Aquasure Quantum UV Water Purifier System. For MAXIMUM effectiveness please thoroughly read this manual. The information listed in this manual covers the steps for a self-serve installation.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS System Inspection ..............4 Installation Diagram .............. 5 Safety Instructions ..............6 Operation Parameter ............7 System Installation ..............8 Operation & Maintenance ..........16 System Warning & Troubleshooting ......18 Warranty .................. 21 Registration ................22 Français ..................
  • Page 4: System Inspection

    If any part is cracked or broken, please do not proceed with the installation and contact Aquasure or your distributor for an exchange or diagnosis.
  • Page 5: Installation Diagram

    INSTALLATION DIAGRAM...
  • Page 6: Safety Instructions

    SAFETY INSTRUCTIONS WARNING - To guard against injury, basic safety precautions should be observed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. CAUTION - Disconnect power before servicing. DANGER - To avoid possible electric shock, special care should be taken since water is present near electrical equipment.
  • Page 7: Operation Parameter

    OPERATION PARAMETER IMPORTANT: The following conditions for feed water supply must be met or warranty will be void and the manufacturer assumes no responsibility for damage to system or property. Water Temperature Parameter The system MUST NOT be installed in an area where it is exposed to direct sunlight and must be protected against freezing and extreme heat.
  • Page 8: System Installation

    UV lamp. Ideally the clearance should consider the length of the UV lamp and the ballast prong connector. IMPORTANT: It is recommended that the Quantum UV system be mounted in a vertical position. This ensures optimal contact time for the UV wavelength inside the UV chamber to sterilize contaminants.
  • Page 9 IMPORTANT: Make sure the inlet and outlet ports on the UV chamber are clear from any obstruction and plumbing can be routed to the location of the install. Quantum UV Mounting Surface Quantum UV Mounting Surface Before connecting plumbing lines assemble the unit and install the quartz sleeve and UV lamp.
  • Page 10 STEP 3: Connecting the UV System IMPORTANT: On copper plumbing systems, be sure to install a grounding wire between the inlet and outlet piping to maintain grounding. WARNING! Any solder joints being soldered near the valve must be done before connecting any piping to the system. Always leave at least 6” (152 mm) between the UV system and joints being soldered when soldering pipes that are connected to the UV system.
  • Page 11 Insert the quartz sleeve into the UV chamber. IMPORTANT: The quartz sleeve is fragile and should be handled with care. Positioning the UV chamber vertically and slowly lowering the quartz sleeve into the UV chamber. This method can avoid the sleeve making contact with the inner surface of the UV chamber.
  • Page 12 Determine which end of the UV system will be on top or will be receiving power and connected to the ballast. Designate and install the open end cap on this side of the UV system. IMPORTANT: Hand tighten the end caps onto the UV chamber. Overtightening or tightening with the use of tools could result in damage to the quartz sleeve.
  • Page 13 With the ballast plug connected to the UV lamp slowly and carefully insert the UV lamp into the open end cap and into the quartz sleeve. IMPORTANT: The UV lamp is fragile and should be handled with care. Slowly lower the UV lamp into the end cap and into quartz sleeve can prevent the glass components from making contact with each other and preventing breakage.
  • Page 14 STEP 5: Flushing and testing the plumbing lines WARNING! If the system is leaking at all, turn the unit to the bypass position and shut off main water supply before assessing leak. IMPORTANT: Flushing the system lines is necessary to ensure that all plumbing work has been done correctly, that there is no debris or air trapped in the piping, and that there are no leaks.
  • Page 15 CONGRATULATIONS! Your system is ready to use. Please document the system installation date and replace the UV lamp in the suggested replacement time. Be sure to register your system within 60 days of purchase. Scan the QR code below or go to aquasureusa.com/warranty to register your system. Scan to register your system...
  • Page 16: Operation & Maintenance

    OPERATION & MAINTENANCE Quartz Sleeve Replacement And/Or Cleaning: If the water contains any hardness minerals (calcium or magnesium), iron or manganese, the quartz sleeve will require periodic cleaning. To remove the quartz sleeve, first the UV lamp as outlined above: Shut off water supply and drain all lines.
  • Page 17 UV Lamp Replacement And/Or Cleaning: WARNING! Regularly inspect your disinfection system unit to ensure the UV light is still glowing. Replace the UV lamp annually to ensure a high bacteria and virus kill rate. IMPORTANT! During the assembly and handling of the quartz sleeve and or UV Lamp it is recommended to wear plastic gloves.
  • Page 18: System Warning & Troubleshooting

    SYSTEM WARNING & TROUBLESHOOT Lamp Failure System The audible alarm and indicator lights on the systems continuously monitor the lamp operation. If the lamp does not start at any time, the indicator red light will glow and audible alarm will sound. This alarm indicated the UV lamp is no longer operating and must be corrected.
  • Page 19 WARNING! When there is no flow, the water in the cell will become warm, as the UV disinfection system lamp is always on. To remedy this, run cold water tap anywhere in the house for a minute to flush out the warm water. As the system requires time to reach its full operating capacity, please allow the disinfection system to operate 3-5 minutes prior to using the water from unit.
  • Page 20 SYSTEM STATUS REMARKS LAMP AUDIBLE STATUS UV LAMP ALARM (GREEN LED) Correct operating conditions, unit is functioning properly The UV lamp is spent, requires replacement lamp. UV lamp not connected to power source. Check connection and reconnect lamp. Ballast has switched off. To reset ballast remove power to unit by disconnecting power cord from electrical plug for a minimum of 30 seconds then reapply power.
  • Page 21: Warranty

    (1) year from the date of purchase by the original owner on a pro-rated basis. With an additional two (2) years of coverage for products registered with Aquasure within 60 days of the original purchase date.
  • Page 22: Registration

    GET AN ADDITIONAL TWO YEARS OF COVERAGE FOR FREE! Simply scan the QR code below or go to aquasureusa.com/warranty to register your new Aquasure Quantum UV system. Scan to register your system...
  • Page 23 NOTES...
  • Page 24: Français

    Pour une efficacité MAXIMALE, veuillez lire attentivement ce manuel. Les informations énumérées dans ce manuel couvrent les étapes d’une installation en libre-service. Si vous avez besoin d’aide, nos techniciens Aquasure sont à votre disposition pour répondre à vos questions pendant les heures d’ouverture indiquées ci-dessous. Téléphone:...
  • Page 25 Exploitation et maintenance ........... 38 Avertissement et dépannage du système ....40 Garantie ..................43 Inscription ................44 LEGEND ATTENTION PROTECTION DES YEUX AVERTISSEMENT ÉLECTRIQUE TERRE DE PROTECTION FRAGILE Français | AQUASURE WHOLE HOUSE ULTRA VIOLET UV) WATER PURIFIER SYSTEM | 25...
  • Page 26: Inspection Du Système

    été endommagé pendant le transport. Si une pièce est fissurée ou cassée, ne la remettez pas en place. poursuivre l’installation et contacter Aquasure ou votre distributeur pour un échange ou un diagnostic.
  • Page 27: Schéma D'installation

    SCHÉMA D’INSTALLATION Français | AQUASURE WHOLE HOUSE ULTRA VIOLET UV) WATER PURIFIER SYSTEM | 27...
  • Page 28: Instructions De Sécurité

    SAFETY INSTRUCTIONS AVERTISSEMENT - Pour éviter toute blessure, des précautions de sécurité de base doivent être observées, notamment les suivantes: LISEZ ET SUIVEZ TOUTES LES CONSIGNES DE SÉCURITÉ. ATTENTION - Débranchez l’alimentation avant de procéder à l’entretien. DANGER - Pour éviter tout risque d’électrocution, il convient de prendre des précautions particulières en cas de présence d’eau à...
  • Page 29: Paramètre De Fonctionnement

    Transmittance UV: > 75% (appelez l’usine pour des recommandations sur les applications où UVT < 75%) * Lorsque la dureté totale est supérieure à 7 gpg, l’eau doit être adoucie. Français | AQUASURE WHOLE HOUSE ULTRA VIOLET UV) WATER PURIFIER SYSTEM | 29...
  • Page 30: Installation Du Système

    UV. Idéalement, l’espace doit tenir compte de la longueur de la lampe UV et du connecteur de la broche du ballast. IMPORTANT: Il est recommandé de monter le système Quantum UV en position verticale. Cela garantit un temps de contact optimal pour la longueur d’onde UV à...
  • Page 31 IMPORTANT: Assurez-vous que les orifices d’entrée et de sortie de la chambre UV ne sont pas obstrués et que la plomberie peut être acheminée vers le lieu d’installation. Quantum UV Surface de montage Quantum UV Surface de montage Avant de connecter les lignes de plomberie, assemblez l’unité...
  • Page 32 ÉTAPE 3 : Connexion du système UV IMPORTANT: Sur les systèmes de plomberie en cuivre, veillez à installer un fil de mise à la terre entre les tuyaux d’entrée et de sortie pour maintenir la mise à la terre. AVERTISSEMENT! Toute soudure à proximité de la vanne doit être effectuée avant de raccorder une quelconque tuyauterie au système.
  • Page 33 Faites rouler délicatement le joint torique noir sur l’extrémité du manchon en quartz. Procédez de la sorte pour les deux côtés du manchon de quartz exposé et pour les deux embouts. Français | AQUASURE WHOLE HOUSE ULTRA VIOLET UV) WATER PURIFIER SYSTEM | 33...
  • Page 34 Déterminez l’extrémité du système UV qui sera sur le dessus ou qui sera alimentée et connectée au ballast. Désignez et installez l’embout ouvert de ce côté du système UV. IMPORTANT: Serrez à la main les embouts sur la chambre UV. Un serrage excessif ou un serrage à...
  • Page 35 éviterez que les composants en verre n’entrent en contact les uns avec les autres et ne se cassent. Fixez le manchon du ballast sur l’embout. Veillez à ce qu’il soit bien en place pour éviter que la lampe ne se déconnecte. Français | AQUASURE WHOLE HOUSE ULTRA VIOLET UV) WATER PURIFIER SYSTEM | 35...
  • Page 36 ÉTAPE 5 : Rinçage et test des conduites de plomberie AVERTISSEMENT! Si le système présente la moindre fuite, mettez l’unité en position de dérivation et coupez l’alimentation principale en eau avant d’évaluer la fuite. IMPORTANT: Le rinçage des conduites du système est nécessaire pour s’assurer que tous les travaux de plomberie ont été...
  • Page 37 Veillez à enregistrer votre système dans les 60 jours suivant l’achat. Scannez le code QR ci-dessous ou allez sur aquasureusa.com/warranty pour enregistrer votre système. Scanner pour enregistrer votre système Français | AQUASURE WHOLE HOUSE ULTRA VIOLET UV) WATER PURIFIER SYSTEM | 37...
  • Page 38: Exploitation Et Maintenance

    FONCTIONNEMENT & MAINTENANCE Remplacement de la douille du quartz et / ou nettoyage: Si l’eau contient des minéraux de dureté (calcium ou magnésium), du fer ou du manganèse, le manchon de quartz devra être nettoyé périodiquement. Pour retirer le manchon de quartz, commencez par la lampe UV comme indiqué...
  • Page 39 It will be necessary to shock the system with household bleach for a full 20 minutes before resuming use of the water. Français | AQUASURE WHOLE HOUSE ULTRA VIOLET UV) WATER PURIFIER SYSTEM | 39...
  • Page 40: Avertissement Et Dépannage Du Système

    ALERTE ET DÉPANNAGE DU SYSTÈME Système de défaillance de la lampe L’alarme sonore et les témoins lumineux des systèmes surveillent en permanence le fonctionnement de la lampe. Si la lampe ne s’allume pas à un moment donné, le voyant rouge s’allume et l’alarme sonore retentit. Cette alarme indique que la lampe UV ne fonctionne plus et doit être corrigée.
  • Page 41 à une humidité désinfection et contrôler l’humidité excessive Connexions inadéquates des Vérifier les raccords filetés, les rendre étanches ports d’entrée/sortie avec du ruban téflon et les resserrer. Français | AQUASURE WHOLE HOUSE ULTRA VIOLET UV) WATER PURIFIER SYSTEM | 41...
  • Page 42 SYSTEM STATUS REMARQUES ÉTAT DE LA ALARME LAMPE (LED LAMPE UV AUDIBLE VERTE) Conditions de fonctionnement correctes, l’unité fonctionne correctement La lampe UV est usée, il faut la remplacer. La lampe UV n’est pas connectée à la source d’alimentation. Vérifiez la connexion et rebranchez la lampe.
  • Page 43: Garantie

    à l’installation de toute unité de remplacement. Cette garantie limitée ne s’applique qu’à un appareil retourné au garant aux frais du propriétaire et conformément aux instructions d’expédition reçues du garant. Français | AQUASURE WHOLE HOUSE ULTRA VIOLET UV) WATER PURIFIER SYSTEM | 43...
  • Page 44: Inscription

    GRATUITEMENT DEUX ANNÉES SUPPLÉMENTAIRES DE COUVERTURE ! Il vous suffit de scanner le code QR ci-dessous ou de vous rendre sur aquasureusa.com/warranty pour enregistrer votre nouveau système UV Aquasure Quantum. Scanner pour enregistrer votre système 44 | www.AQUASUREUSA.com Tel: 1-800-661-0680...
  • Page 45 NOTES...
  • Page 46 AquasureUSA.com | 800.661.0680 | support@aquasureusa.com...