How to Install the Unit
1
Measure the space for installation to assure a
good fit. The air conditioner must be installed
firmly into place to prevent vibration and noise.
2
Avoid exposure to direct sunlight.
3
Remove all obstacles from the rear of the
unit. There must be at least 50 cm (20 in.)
of cleared space around the rear of the unit.
Obstacles restricting the airflow may reduce
the cooling efficiency of the unit.
4
The unit should be installed with a slight tilt
towards the outside to allow condensed water
to drain. (About 10~15 mm or 1/4 bubble with
Level)
Foam
Cooled air
(Minimum
installation
height is 75cm)
75-150cm
Installation
Frame
CAUTION
• The external grille must be exposed outside for
air discharge.
• As the minimum installation height is 75cm.
Please be aware the requirement of installation
height.
10
Fence
Awning
Heat
radiation
10~15 mm
Over 50 cm
1/4 Bubble
Level
Drainage (Optional)
The base-pan may overflow due to high humidity.
To drain the excess water, remove the drain cap
from the base pan of the unit and secure the Drain
Pan.
1
Remove the rubber cap from the hole under
the base-pan.
2
Install the drain pan over the corner of the
installation frame with 2-4 screws. (Drain
Pan can be install in 4 directions. You can
purchase the installation frame locally to
satisfy your particular needs. Installation frame
is not supplied.)
Installation
Installation
Frame
Frame
Hose
Hose
3
Connect the drain hose to the outlet located
on the bottom of the drain pan. (You can
purchase the drain hose or tubing locally to
satisfy your particular needs. Drain hose is not
supplied.)
EN
Screw
Screw
Drain Pan
Drain Pan