TCF MPLFN Installation, Operation & Maintenance Manual

TCF MPLFN Installation, Operation & Maintenance Manual

Modular plenum fans

Advertisement

Quick Links

Twin City Fan
Throughout this manual, there are a number of HAZARD WARNINGS that must be read and adhered to in order to prevent possible
personal injury and/or damage to equipment. Two signal words "WARNING" and "CAUTION" are used to indicate the severity of a hazard
and are preceded by the safety alert symbol.
WARNING
Used when serious injury or death MAY result from misuse or failure to follow specific instructions.
CAUTION
Used when minor or moderate injury or product / equipment damage MAY result from misuse or failure to follow specific instructions.
NOTICE
Indicates information considered important, but not hazard-related.
It is the responsibility of all personnel involved in installation, operation and maintenance to fully understand the
Warning and
Caution procedures by which hazards are to be avoided.
Contents
Introduction.................................................................................... 1
Shipping and Receiving .................................................................. 1
Handling ......................................................................................... 2
Short Term Storage ......................................................................... 2
Long Term Storage .......................................................................... 2
Foundations and Supporting Structures ........................................2
Fan Installation ............................................................................... 3
Assembly of Fans ............................................................................ 3
Electrical Wiring of Fans ................................................................. 4
Fan Operation - Safety ................................................................... 4
Operation Checklist ........................................................................ 4
Maintenance of Fans ...................................................................... 5
General Motor Maintenance..................................................... 5
Impeller and Shaft Maintenance ............................................... 5
Structural Maintenance ............................................................. 5
Troubleshooting Guidelines ........................................................... 5
Air Capacity Problems ............................................................... 5
Noise Problems ......................................................................... 5
Vibration Problems .................................................................... 5
Motor Problems ........................................................................ 6
Limitation of Warranties and Claims .............................................. 6

Introduction

The purpose of this manual is to provide instructions that complement
good general practices when installing or operating fans manufactured
by Twin City Fan & Blower. It is the responsibility of the purchaser to
provide qualified personnel experienced in the installation, operation
and maintenance of air moving equipment.
Instructions given in the body of this manual are general in nature and
apply to a variety of models manufactured by Twin City Fan & Blower.
Most units can be installed and maintained with the instructions given.
Additional product and engineering information is available at www.tcf.
com.
Modular Plenum Fans
(MPLFN, MPLFS, MPLQN, MPLQS)
INSTALLATION, OPERATION & MAINTENANCE MANUAL
©2014 - 2023 Twin City Fan Companies, Ltd.
Special applications may require additional information. These
instructions are supplied in the form of attached appendices. Use the
instructions in the appendix if the directions in this manual differ from
instructions in the appendix.
As always, follow good safety practices when installing, maintaining and
operating your air moving equipment. A variety of safety devices are
available. It is the user's responsibility to determine adequate safety
measures and to obtain the required safety equipment.

Shipping and Receiving

All Twin City Fan & Blower products are carefully constructed and
inspected before shipment to insure the highest standards of quality
and performance.
Compare all components with the bill of lading or packing list to verify
that the proper unit was received.
Check each unit for any damage that may have occurred in transit.
Any damage should be reported immediately to the carrier and the
necessary damage report filed.
Figure 1. Lifting Lug Locations
IM-495
April 2023
NOTE: When lifting, the straps/
chains should be at a minimum
angle of 45°
DETA
SCALE

Advertisement

Table of Contents
loading

Summary of Contents for TCF MPLFN

  • Page 1: Table Of Contents

    Twin City Fan & Blower. DETA SCALE Most units can be installed and maintained with the instructions given. Additional product and engineering information is available at www.tcf. NOTE: When lifting, the straps/ chains should be at a minimum com.
  • Page 2: Handling

    Start-Up – When the unit is removed from storage, all bearing Handling grease should be purged and replenished with fresh grease as per Handling of all air moving equipment should be conducted by the lubrication decal. The motor resistance should be measured to trained personnel and be consistent with safe handling practices.
  • Page 3: Fan Installation

    2. The bolts to be snugged up on vertical sections for the first row. Table 1. Torque Values MPLFN/MPLFS/MPLQN/MPLQS Fasteners Once all fasteners are in place, the bolts shall be tightened to torque Torque Values values in table.
  • Page 4: Electrical Wiring Of Fans

    “locked-off” by the service person and the key to be retained by □ Run unit up to speed. this person to prevent accidental power of the fan while service is in process. Figure 5. Proper Impeller Rotation Figure 4. Impeller-Funnel Overlap MPLFN, MPLFS, MPLQN & MPLQS Wheels MPLFN/MPLFS/MPLQN/MPLQS Size Size 245/245C 12.75...
  • Page 5: Maintenance Of Fans

    Maintenance of Fans Troubleshooting Performance This section contains general maintenance instructions for your Problems Twin City Fan & Blower unit. For specific information about The lists below indicate possible areas to check when air or sound values maintenance of components, particularly for special application do not match expectations.
  • Page 6: Motor Problems

    Motor Problems: Limitation of Warranties and Claims 1. Incorrect wiring. Seller warrants to the original purchaser that the goods sold hereunder shall be free from defects in workmanship and material 2. Speed of fan too high. under normal use and service (except in those cases where the 3.