  • Page 1 ® PWHY Digital Crane Scales User’s Manual / Manual de usuario Safety Warnings / Advertencias de Seguridad...
  • Page 2 PWHY PWHY5T PWHY10T PWHY25T PWHYCS1T PWHY50T PWHY100T PWHYCS5T PWHYCS10T PWHYCS20T V.02.23 [LM]...
  • Page 3 PWHY PWHYCS30T PWHYCS50T PWHY280 PWHY680 PWHY18 V.02.23 [LM]...
  • Page 5: Table Of Contents

    Calibration Instructions........................24 Storage Function..........................24 Search Function..........................24 Addition Function..........................25 Delete Function..........................25 Maximum Value Display......................25 Maximum Value Display......................25 Blacklight Function........................25 Adjust Time Function........................26 Technical Parameters........................27 Dimensions............................28 PWYCS........................29 Installation............................29 Calibration............................29 Operation............................29 Dimensions............................33 Optional.............................34 Crane Scale Prowinch Website Interface................35 Accesories ............................36 MAPS PROWINCH® ....................37...
  • Page 6: Prowinch® Disclaimer

    For purposes of enforcing the warranty of the product purchased, Prowinch® LLC, will only be liable for any damage when proven the user has followed each one of the warnings contained in the User Manual and Safety.
  • Page 7: Safety Precautions

    They are designed to accurately and precisely measure loads of di e- rent dimensions. Your shipping module allows the transmission of real-time data that can be read and recor- ded by means of a wireless receiver (PWHY280). We recommend always using Prowinch® parts and acces- sories.
  • Page 8 SAFETY PRECAUTIONS WARNING: This symbol indicates unsafe practices or situations which may cause damage to the property and even injuries to the personnel. DANGER: This symbol indicates a potentially dangerous situation which if not avoided may cause severe injuries or death Read and understand the contents of this User Manual thoroughly before handling the product.
  • Page 9: General Precautions

    • Be sure to remove the batteries when they are not used the equipment owner. for long periods. • Verify that the chosen PWHY series dynamometer is suita- • Do not wear loose clothing or jewelry ble for the type of load you wish to measure and that the •...
  • Page 10: Handling Precautions

    SAFETY PRECAUTIONS 2.2 HANDLING PRECAUTIONS Do not overload the dyna- Do not stand under the load mometer.Check the load capacity or allow others to do so. before equipment. Check the electrical connections. Voltage may vary if not properly connected to power supply. Regularly calibrate your...
  • Page 11: General Enviromental Precautions

    SAFETY PRECAUTIONS 2.3 GENERAL ENVIROMENTAL PRECAUTIONS Verify that your equipment model is suitable for the environmental conditions in which it will be used When used outdoors, a shelter is required to protect from harsh environmental conditions. Temperatures below -10º C and above 40º C and / or Relative humidity of 85% can cause failure of the team.
  • Page 12: Specifications

    Speci cations 3.1 INTRODUCTION The digital wireless weighing instrument of our factory adopts the high precision weight sensor and weighing instrument With the A / D switch, it features high reliability and good precision. 3.2 Carachteristics • The waterproof, anti-collision and durable instrument case. •...
  • Page 13: Interruptor

    Speci cations Interruptor Power on: Press the red button and hold it until the interface and version number appear. Shutdown: Press the red button and hold it until the system shuts down. You can also press the [Reset] button to force shutdown when system is not normal.
  • Page 14: Main Interface

    Speci cations Main Interface 0.0kg TRUCK: GOODS: DATE: 05/20/2020 Tuesday (1) The remaining energy, (2) The strength of the wireless signal, appears "" when the signal is strong and "?" when no signal is detected. (3) The current weight appears when communication is normal and “-------” when the signal is not detected. (4) Truck number, press the [1 / Truck number] button to enter a number, press the [2 / ABC] button to enter other ASCI numbers.
  • Page 15: Time Con Guration / Hour

    Speci cations 3.6.1 Time Con guration / Hour Time / Date Adjustment Data: 2020 Time: 04 : Press Up/ Down / Left / Right to choose the zone, type the numbers and press [OK] to save. The con gura tion time here is the time that is on the saving and printing data.
  • Page 16: Weight Unit

    Speci cations 3.6.4 Weight Unit Unit Choose: Press Up/ Down to select the unit and weight then press [OK] to save. While the normal use if the unit change, the value will adjust automatically depends from the new unit. 3.6.5 Division Value Dividing Value Choose Press Up / Down / Left / Right to choose division unit and press ¨OK¨...
  • Page 17: Zero Point Tracking

    Speci cations 3.6.7 Zero point tracking Zero Tracking Choose: +/-3d +/-1d +/-2d +/-4d +/-5d +/-6d Press Up / Down / Left / Right to choose the parameters and press ¨OK¨ to save it. When the weight current is equal to or less than the minimum division, “0”...
  • Page 18: Other Settings

    Speci cations 1- TOLEDO STX A B C X6 X5 X4 X3 X2 X1 N6 N5 N4 N3 N2 N1 CR X6 X5 X4 X3 X2 X1 The displayed data, X1 is low, X6 is high; N6 N5 N4 N3 N2 N1 The tare data, N1 is low, N6 is high; A B C Bit status A = 1 1 0 0 0 d2 d1 d0 d2-d0 = 0 without the decimal point...
  • Page 19: Calibration

    Speci cations 3.6.10 Calibration Enter the initial password (“123456”) to activate the calibration function. Calibration 1 - IMaximum Range 2 - Zero adjustment 3 - Span Adjustment 1. Setting the nominal range Press [OK] to enter, it will appear “1-rated range = 010000 kg” on the interface. Enter the maximum range, press [OK] to save it. When the weight is greater than the maximum value, the alarm will be activated automatically.
  • Page 20: Maintenance

    Speci cations 3.7 Maintenance HY680 is a measuring instrument with high precision. Proper maintenance is essential to increase the reliability and extend the life of the equipment. The instrument is earthquake resistant and waterproof, but you still need to avoid collision and protect it from rain, particularly by preventing it from falling o the hook.
  • Page 21: Warranty

    Limited Warranty Coverage. Prowinch guarantees this product, for three (3) years from the purchase date, against any defect in the materials and workmans- hip used for its manufacture. Our warranty includes repair or change of components at no charge to the customer, including labor.
  • Page 22: Exclusions

    Connection of electrical or electronic components powered by external sources (Normal Network), subject to potential varia- tions. When the product has been disassembled, modi ed or repaired by persons not authorized by Prowinch. When the normal wear of the parts causes the failure due to use.
  • Page 23: Pwhy280

    PWHY PWHY280 LCD display: 192x64 pixels, 6 status indicators Power: 7.4V / 2.2AH Lithium Battery, up to 48h of use per charge Ambient Temperature: -10ºC ~ 50ºC % Humidity: ≤85%, at 20ºC Maximum Distance for Wireless Receiver: 200 m (open areas) Radio Frequency: 430 ~ 470MHz SCREEN SYMBOLS Stable...
  • Page 24: Calibration Instructions

    PWHY Calibration Instructions STEPS OPERATION SCREEN NOTE Pulse (OK) [P 0000] Pulse (OK) [P 8888] Move the cursor and change the numbers to your password Pulse [^] o [v] Set the desired precision: 1, 2, 5, 10, 20, Pulse [>>] [E 001] 50, 100 Pulse [OK]...
  • Page 25: Addition Function

    PWHY Addition Function STEPS OPERATION SCREEN NOTE Pulse Pulse [C] Deleted Function OPERATION SCREEN NOTE STEPS Pulse [CLR 0] Pulse [>>] 1. Erase the last register data. [CLR *] Pulse [OK] 2. Deleted all register data. [END] Maximum value display STEPS OPERATION SCREEN...
  • Page 26: Adjust Time Function

    PWHY Adjust time function STEPS OPERATION SCREEN NOTE Pulse [11-01-01] Show the current date in the system Pulse [>>] or Pulse Move the cursor and set the curent date, [^] o [ v ] Pulse [OK] to save Pulse [OK] Pulse Show the current date.
  • Page 27: Technical Parameters

    PWHY Technical Parameters CODE PWHY5T PWHY10T PWHY25T PWHY50T PWHY100T Accuracy Grade III Grade III Grade III Grade III Grade III Grade Rated 11000 Lb 22000 Lb 55000 Lb 110000 Lb 220000 Lb Capacity Sensitivity (2.0 ± 0.1%) m V/V (2.0 ± 0.1%) m V/V (2.0 ±...
  • Page 28: Dimensions

    PWHY Dimensions CODE PWHY5T PWHY10T PWHY25T PWHY50T PWHY100T 9.0 in/ 230mm 11.0 in 14.6 in 16.9 in 22.4 in 6.3 in 7.4 in 9.0 in 10.2 in 5.4 in 3.0 in 3.5 in 0.9 in 5.9 in 8.3 in 1.3 in 1.8 in 2.2 in 2.6 in...
  • Page 29: Pwycs

    PWHYCS PWHYCS Accuracy: Grade III, n = 3000 Sampling Rate: 80 times / second Interval scale: 1/2/5/10/20/50 per option Display: 6-bit LCD, 6-stage light indication Communication interface: wireless signal Power Source: AA 1.5Vx3 batteries Operation Temperature / Humidity: -10 ~ 45 ° C; 90% RH Transport Temperature: -20 ~ 50 Installation •...
  • Page 30 PWHYCS OPERATION Accuracy: Grade III, n = 3000 Sampling Rate: 80 times / second Interval scale: 1/2/5/10/20/50 per option Display: 6-bit LCD, 6-stage light indication Communication interface: wireless signal Power Source: AA 1.5Vx3 batteries Operation Temperature / Humidity: -10 ~ 45 ° C; 90% RH Transport Temperature: -20 ~ 50 Switch On And Automatic Zero Con guration •...
  • Page 31 PWHYCS 2400 1200 RS232 Weight option of out net/gross Net / Weight output Net / Weight output RS232 Output option mood Without transmission (Stop RS232) X=1: Transmission continuous 1 X=2: Continuous transmission when stabilized X=3: Command mode (Z: zero, T: Tare, R: transmit weight data X=4: once) X=5:...
  • Page 32 PWHYCS Error Indication ERR 1 Values is too small when is calibrated EER 2 Point zero is out of the range when is calibrated EER 3 Point zero is out of range when turn on EER 4 The sample number entered is zero when sampling in counting mode EER5 The entered weight is zero when full scale is calibrated in calibration mode EER6...
  • Page 33: Dimensions

    PWHYCS Dimensions CODE PWHYCS1T PWHYCS5T PWHYCS10T PWHYCS20T PWHYCS030T PWHYCS50T 9 5/8 in 11 1/4 in 12 1/3 in 16.5 in 16.5 in 18.3 in 244.5 mm 286 mm 318 mm 420 mm 420 mm 465 mm 3 3/4 in 4 in 4 1/2 in 4.8 in 5.4 in...
  • Page 34: Optional

    Optionals PWHY680 PWHY280 Remote control with display and printer Simple remote control with display Software and wireless interface for dinamometers of PWHYCS and PWHYCS Series. Direct connection with PWHYCS Series Connection with PWHY series requires a PWHY280/680 Unit V.02.23 [LM]...
  • Page 35: Crane Scale Prowinch Website Interface

    PWHYCS Crane scale Prowinch website Interface ® User Menu Input Help Current Load Peak Load 0 lb 1250 lb Customer: Product ID: Description: Time V.02.23 [LM]...
  • Page 36: Accesories

    PWHYCS Accesories PWHYD PWHYA 3, 5, 8, In font Display for PWHY series Crane Scales 3 Antenna 650 Ft for PWHY Crane Scale series PWHYA300 3Antenna 1000 Ft for PWHY Crane Scale series V.02.23 [LM]...