Examination Basic Flow

1. Start up
2. Data transfer
and system
2.1 AUTOREF Data
initialization
2.2 LM Data
1. Start up and System Initialization
L40P
RG24RT
turn on the chart instruments

Plano Exam - VA Check

Press
Press R, L or R&L
Plano

2.1 Data Input/Transfer from Autoref

To transfer data, press/touch
- Speedy K2 - touch screen
- Speedy i/iK - press
- Retinomax - press

2.2 Data Input/Transfer from Lens Meter

to trasnfer data, press
of LM screen
select COM by setting menu if
LINK indicated on LM screen
AUTOREF or LM data transferred first will be copied in SBJ1
3. PD and Forehead Rest Adjustment
press SBJ1,
if in other
press PD
status
turn dial and set the corneal
vertex distance

4.1 Preset Program EXAM.

press
press
to start, status should
be SBJ1 or SBJ2
After change of chart instrument, in the program menu screen, touch RESET to show SET and EDIT
RVII Quick Reference
Operation by
Please refer to RVll Instruction Manual for details.
3. PD and forehead
rest adjustment
turn on the RVll power box
SET IN
Press ▲▼
to check
Press
highest VA
SET
Dot matrix LED
indicates
Data receive
To receive data
press
AUTOREF or LM data transferred first will be copied in SBJ1
Dot matrix LED
indicates
Data receive
To receive data
press
select program
on control box
screen, then
touch SET for
start
turn jog dial for adjust
Remote Control (RC)
Basic Flow
4. Exam
4.1 Preset program

4.2 Individual Exam.

To initialize RVll system
- auto initialized as turn on
power, or
- manual initialization
press AC twice, or
- changed communication
setting and saved
Press R,L,S,C,A to set
Blinking
the value
for set
Selectable receiving 1 or 10 data in setting menu "Communication Setting 2"
After press REF, if selected receiving 1 data, Autoref data is set
After press REF, if
selected receiving 10
data, select data
number in dot screen
Selectable receiving 1 or 10 data in setting menu "Communication Setting 2"
After press LM, if selected receiving 1 data, Autoref data is set
After press LM, if
selected receiving 10
data, select data
number in dot screen
VD:12mm
turn jog dial for
PD adjust
VD:13.75mm
press BACK
return to
previous
press NEXT
for next step
refer to Leaflet "Program
Examination" for details
6. Print and/or data to PC
Press
SET IN function is equipped after ver.3.02.01.
Press NEXT or
BACK to select
Press NEXT or
BACK to select
To adjust split PD
press R or L
Selectable preset programs
program finish if
Program
"End Program"
indicated on
Prog1(editable)
screen of CB
Prog2(editable)
Speedy
21point
MCH
RVll R3 ver.2

Setting Menu

Main Menu

Simple Setting

Eye Exam

Program Edit

Factory Default

Initial Setting

Back to previous
to cancel SET IN
Press SET IN,
to set the lens
Press SET
Press SET
press OFF
to exit PD
turn jog dial for
PD adjust
NP3S
Pola
RG
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RVII and is the answer not in the manual?

Questions and answers

Summary of Contents for Righton RVII

  • Page 1 RVll R3 ver.2 RVII Quick Reference Operation by Remote Control (RC) Please refer to RVll Instruction Manual for details. Examination Basic Flow Setting Menu Basic Flow 1. Start up 2. Data transfer 3. PD and forehead 4. Exam 5. Data comparison Main Menu 4.1 Preset program...
  • Page 2 4.2.1 Astigmatism EXAM. press press A, SBJ1 press chart turn jog dial turn jog dial turn jog dial press C ask "any key and to the axis turn jog dial to - until a to - 0.25 until line look exam press S show...

Table of Contents