Quick Start Manual
www.waiglobal.com

Advertisement

loading

Summary of Contents for WAI WAI1000

  • Page 1 Quick Start Manual www.waiglobal.com...
  • Page 2 All information, illustrations, and specifications contained in this technical instruction manual are based on the latest information available at the time of publication. WAI Global reserve the right to make changes at any time without obligation to notify any person or organization of such revisions or changes.
  • Page 3 5- COM terminal - control line for ECU protocols 6- DFM monitor positive field order 7- DFM monitor negative field order Turn knob clockwise or counter clockwise to switch between options (1&2). Confirm your selection by pushing the knob (3). WAI1000 Tester Quick Start Manual...
  • Page 4 *Note - green wire is always used to control alternator After connecting the WAI1000 to a power source it will bring up the protocol menu. Please select the proper protocol with the control knob and submit your option by pressing it.
  • Page 5 When changing the Vset value Vread should decrease or increase accordingly If the regulator supports DFM while Vset changes the value should also change Pressing the control knob makes the WAI1000 go back to the protocol selection screen WAI1000 Tester Quick Start Manual...
  • Page 6 If the regulator supports DFM, whilst Vset changes the value should also change. Pressing the control knob makes the WAI1000 go back to the protocol selection screen. Note: Small difference between the voltage is acceptable. What is important is the appropriate reaction of the alternator –...
  • Page 7 When changing the Vset value Vread should decrease or increase accordingly If the regulator supports DFM while Vset changes the value should also change Pressing the control knob makes the WAI1000 go back to the protocol selection screen WAI1000 Tester Quick Start Manual...
  • Page 8 When information about the regulator shows up you can control the Voltage by rotating the control knob When changing the Vset value Vread should decrease or increase accordingly Pressing the control knob makes the WAI1000 go back to the protocol selection screen WAI1000 Tester Quick Start Manual...
  • Page 9 When changing the Vset value Vread should decrease or increase accordingly If the regulator supports DFM while Vset changes the value should also change Pressing the control knob makes the WAI1000 go back to the protocol selection screen WAI1000 Tester Quick Start Manual...
  • Page 10 When changing the Vset value Vread should decrease or increase accordingly If the regulator supports DFM while Vset changes the value should also change Pressing the control knob makes the WAI1000 go back to the protocol selection screen WAI1000 Tester Quick Start Manual...
  • Page 11 COM DFM Main screen DFM 12.6 Vread 1- Terminal 12.6 2- Read Voltage value Vset 3- Setting of regulator Voltage 4- DFM Testing DFM terminal regulators The DFM Monitor option enables DFM monitoring without controlling alternator WAI1000 Tester Quick Start Manual...
  • Page 12 Reslogistic Av. Coronel Marcos Konder IV/422 Building No. 32, 215 De Bao Rd Park Logistyczny Rogoźnica 1207-Sala West of Govt. BHS Wai Gao Qiao Free Trade Zone Rogoźnica 306 A 7088.301-303 Kodungallur Pudong, Shanghai 200131 30-060 Głogów Małopolski Itajai-SC Kerala Peoples Republic of China (k.Rzeszowa)