  • Page 1 Griddle User Manual...
  • Page 2 Table of Contents...
  • Page 3 GRID30 Safety Warnings & Codes .........04 Safety & Installation Instructions ......06 Where To Install The Griddle ........11 Gas Safety Requirements .........13 Typical Building Dimensions ........18 Cleaning & Maintenance ..........19 Operating Instructions ..........21 Griddle Parts List .............23 Warranty ..............25...
  • Page 4: For Your Records

    Liquid propane & natural gas configurations THANK YOU Thank you for your purchase. We’d like to welcome you to the Summerset family of luxury outdoor kitchen products and look forward to being a part your home for years to come. As a family business with over 30 years of industry experience, we aim to deliver exceptional quality and personal service.
  • Page 5: Safety Warnings

    Safety Warnings & Codes...
  • Page 6: If You Smell Gas

    IF YOU SMELL GAS 1. Shut off the gas to the appliance. 2. Extinguish any open flame. 3. Open lid to vent. 4. If odor continues, keep away from the appliance, and immediately call your gas supplier or fire department. INSTALLATION CODE AND SUPPLY REQUIREMENTS This griddle must be installed in accordance with local codes and ordinances, or, in the...
  • Page 7: Installation Instructions

    Safety & Installation Instructions...
  • Page 8: General Safety Requirements

    GENERAL SAFET Y REQUIREMENTS WARNING! The installation of this appliance must conform with local codes To Reduce the risk of fire, electrical shock, or or, in the absence of local codes, Either the National Fuel Gas injury, read and follow these basic precautions Code, ANZI Z223.1/NFPA 54, or CAN/CGAB149.1, Natural Gas before operating your gas Griddle.
  • Page 9: Visible Damage

    Position your Griddle so the 23. The Summerset Griddle is not designed/certified for and prevailing wind blows into the front control panel cannot be installed in or on recreational vehicles, portable (at your back when operating), allowing for proper trailers, boats or any other mobile vehicle.
  • Page 10 IMPORTANT: THIS GRIDDLE IS FOR OUTDOORS USE ONLY. WARNING! The Griddle must be installed in masonry or other type of fireproof surround. The unit is not insulated and therefore must be installed or placed with 16” – 18” of side and back clearance from unprotected combustible materials such as wood, Plastic, or stucco with wood framing.
  • Page 11: Ensuring Proper Combustion Air And Cooling Air Flow

    Never fill cylinder more than 80% capacity. If these instructions are not followed, fire causing serious injury or even death may occur. GRID30 For installation in non-combustible locations only. Do not locate under unprotected, overhead combustible surfaces.
  • Page 12 Where to Install the Griddle...
  • Page 13 IMPORTANT! NOTE! THE GRIDDLE IS FOR OUTDOOR USE ONLY. This unit should be installed so that it can be removed at a later date if factory service is required. WARNING! ENSURING PROPER The Griddle must be installed in a masonry or COMBUSTION AIR AND other type of fireproof surround.
  • Page 14 Gas Safety Requirements...
  • Page 15: Lp Gas Hook-Up

    It must be provided with a shut-off valve terminating in gas tank valve outlet. It must include a collar to protect the cylinder valve. The cylinder supply system must be arranged for vapor withdrawal. Do not operate the gas Griddle indoors or in any enclosed area.
  • Page 16 FILLING AND REFILLING LP GAS CYLINDERS All purging and refilling of LP gas cylinders must be performed by qualified personnel in the LP gas industry. Never store a spare LP gas cylinder under or near this appliance. Never fill the LP gas cylinder beyond 80 percent full. Failure to follow these instructions may result in explosion, personal injury or death.
  • Page 17 LIQUID PROPANE A dented or rusty LP cylinder may be hazardous and INSTALLATION NOTE: should be avoided. If in doubt, have it checked by your LP supplier. Always check for leaks after every LP cylinder change. (See Checking For Leaks) Ventilation is required in the enclosure on opposite sides to create cross-ventilation.
  • Page 18: Natural Gas Installation

    WARNING! IF YOU SMELL GAS: 1. SHUT OFF GAS TO THE APPLIANCE RIGHT AWAY LEAK TEST 2. EXTINGUISH ANY OPEN FLAME 3. MAKE SURE THE COVER IS NOT PLACED OVER THE BURNER CAUTION BEFORE TESTING 4. IF GAS SMELL CONTINUES, KEEP NEVER USE THE GRIDDLE WITHOUT FIRST LEAK AWAY FROM THE APPLIANCE AND TESTING THE GAS CONNECTIONS.
  • Page 19 LINE DRAWINGS 6. DO NOT ATTEMPT TO IGNITE THE BURNER FOR GRID30 7. Turn off the main Gas Supply 8. Call a certified/qualified professional to repair the GAS LEAK 9. DO NOT attempt to use the Griddle until the leak...
  • Page 20: Maintenance

    Cleaning & Maintenance...
  • Page 21: Spider And Insect Warning

    SPIDER AND INSECT WARNING GRIDDLE COOKING SURFACE MAINTENANCE Spiders and other insects can nest in the burner of this and any other Griddle, which causes the gas to flow The easiest way to clean the cooking surface is to scrub from the front of the burner.
  • Page 22 Operating Instructions...
  • Page 23: Lighting The Griddle

    BEFORE LIGHTING THE MATCH/BBQ LIGHTER GRIDDLE LIGHTING INSTRUCTIONS: 1. DO NOT ATTEMPT TO LIGHT THE GRIDDLE IF YOU SMELL GAS. 1. Push and turn the knob counter-clock-wise past the “CLICK” position. Hold the knob pushed in for 2-3 2. WARNING! seconds.
  • Page 24 Griddle Parts List...
  • Page 25 GRID30...
  • Page 26: Warranty

    Warranty...
  • Page 28 14520 Delta Ln Suite 105 Huntington Beach, CA 92647 ( 800 ) 966-8126 AMDDIRECT.COM VER. 031523...