OEG 516005260 Installation And Operating Instructions Manual

Enamelled domestic water storage tanks

Advertisement

Quick Links

www.oeg.net
Installation and Operating Instructions
GB
Enamelled domestic water storage tanks

Advertisement

Table of Contents
loading

Summary of Contents for OEG 516005260

  • Page 1 Installation and Operating Instructions Enamelled domestic water storage tanks...
  • Page 2: Table Of Contents

    Overview of our domestic Flanged aperture Contents water storage tanks Draining Notes on safety and use Cleaning Documentation Spare part list Regulations Warranty Work on the storage tank Disposal Place of installation Technical data and connections Intended use Hot water storage tanks Installation / Commissioning 150 –...
  • Page 3 Overview Domestic water storage tanks Hot water storage tank Heat pump storage tank 150 – 500 litres, page 27 300 – 500 litres, page 31 800 – 2,600 litres, page 27 Solar storage tank Built-under domestic water 200 – 500 litres, page 29 storage tank (vertical) 800 –...
  • Page 4: Notes On Safety And Use

    Notes on safety and use This installation and operation manual is absolutely necessary to read before Documentation commissioning / use of the storage tank! In addition, it is part of the scope of delivery, has to be handed over to the user and should always be kept near the place where the storage tank is located.
  • Page 5: Intended Use

    The enamelled domestic water storage tanks are used for indirect heating, storage and the Intended use supply of drinking water to or respectively in the desired temperature in closed systems. The heat is transferred by internal heat exchangers, which are flowed through by hot water (in accordance with VDI 2035) and / or solar liquid (water / glycol mixtures in a ratio of up to 1:1.
  • Page 6: Mixed Installation

    All storage tanks may only be used in closed systems. All connections are to be made Connection pressurised. Connections that are not required must be sealed. In order to minimise heat losses, all lines should be insulated. The storage tank is to be installed in such a way that it can be drained without dismantling.
  • Page 7: Control, Maintenance And Cleaning

    Control, maintenance and cleaning When commissioning – as well as at least once a year – the correct function of the safety Safety valve valve has to be tested. If the safety valve is constantly dripping, this is probably caused by contamination, the pressure in the water pipe exceeds the permitted value or the safety valve is defect.
  • Page 8: Draining

    The domestic water is drained after closing the shut-off valve in the cold water supply line Draining via the drain valve of the safety valve combination while simultaneously opening all hot water valves of the connected functional fittings. Required cleaning intervals are different depending on the water quality and the Cleaning temperature of the storage tank.
  • Page 9: Spare Part List

    Magnesium protective anodes Spare part list 517807400 517807402 517807340 *) 517807355 *) R1¼" x 500, Ø 33 R1¼" x 700, Ø 33 M8 x 500, Ø 33 M8 x 500, Ø 40 Hot water storage tank x *) x *) x *) 1000 x *)
  • Page 10: Warranty

    OEG GmbH grants a warranty on all supplied parts / products based on OEG’s general Warranty terms and conditions. Prerequisite for any warranty claims on the storage tanks is the compliance with the following conditions: • control of the scope of delivery and its delivery condition. In case of doubt, immediate contact / consultation with the delivery company and /or OEG.
  • Page 11: Hot Water Storage Tanks

    Hot water storage tanks 150 – 500 Hot water storage tanks Real volume according to EN 12897 Fire protection class of insulation according to DIN 4102-1 Total height including insulation [mm] 1,020 1,265 1,750 1,725 1,770 Diameter without insulation [mm] Diameter with insulation [mm] Tilt height...
  • Page 12: Hot Water Storage Tanks

    Hot water storage tanks 800 – 2,600 Hot water storage tanks 1,000 1,500 2,250 2,600 Real volume according to EN 12897 1,449 2,241 2,554 Fire protection class of insulation according to DIN 4102-1 Total height including insulation [mm] 1,930 2,350 2,210 2,165 2,450...
  • Page 13: Solar Storage Tanks

    Solar storage tank 200 – 500 Solar storage tank with two (-2) or 200-2 300-2 / 300-3 400-2 500-2 three (-3) smooth-pipe heat exchangers Real volume according to EN 12897 292 / 290 4102-1 Fire protection class of insulation according to DIN Total height including insulation [mm] 1,265...
  • Page 14: Solar Storage Tanks

    Solar storage tanks 800 – 2,250 800, 1,000, 1,500 l 800,1000,1500l 2250 l 2250l Enamelled domestic water storage tanks...
  • Page 15: Heat Pump Storage Tanks

    Heat pump storage tanks 300 – 500 Heat pump storage tanks Real volume according to EN 12897 Fire protection class of insulation according to DIN 4102-1 Total height including insulation [mm] 1,750 1,725 1,770 Diameter without insulation [mm] Diameter with insulation [mm] Tilt height [mm]...
  • Page 16: Built-Under Domestic Water

    Built-under storage tanks (vertical) 80 – 200 Enamelled domestic water storage tanks...
  • Page 17 Für Ihre Notizen … | Notes … | Pour vos notes … | Voor uw aantekeningen …...
  • Page 18 OEG GmbH Industriestraße 1 • D-31840 Hess. Oldendorf info@oeg.net • www.oeg.net Free service number: Phone 00 800-63 43 66 24 • Fax 00 800-63 43 29 24...

This manual is also suitable for:

516008014516005235516005240516005270516005172516008008

Table of Contents