Puretec Radfire™ Commercial UV Water Sanitiser
For correct operation & installation, it is essential to observe these instructions.
User Manual
RI-NSFA Series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Radfire RI-NSFA Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Puretec Radfire RI-NSFA Series

  • Page 1 NSF International against CSA B483.1 and NSF/ANSI 55 for Disinfection Performance, Class A AS/NZS 3497 WM 040223 Global-Mark.com.au User Manual RI-NSFA Series Puretec Radfire™ Commercial UV Water Sanitiser For correct operation & installation, it is essential to observe these instructions. OCT2022...
  • Page 2: Table Of Contents

    This is chemical free process which is simple in its concept and eff ective in its abilities to inactivate microorganisms present in the water supply. Simple maintenance, continuous inactivation and ultimately safe water. Puretec makes it that easy. Customer Service Helpline 1300 140 140 (Australia) 0800 130 140 (New Zealand).
  • Page 3: Safety Considerations

    UV lamp without adequate eye protection and always protect your skin from direct exposure to the UV light. For complete performance, use ONLY genuine Puretec replacement parts. Damage caused from the use of non-genuine replacement lamps or parts, poses a safety risk and is not covered by equipment warranty.
  • Page 4: Safety Information

    Ground Fault Circuit Interrupter (GFCI). This symbol indicates there is a potential for VERY hot water when fl ow is started. Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 5 Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check with a qualifi ed electrician or Puretec if you are in doubt as to whether the outlet is properly grounded. DO NOT modify the plug provided with this system – if it does not fi t in the outlet, have a proper outlet installed by a qualifi...
  • Page 6 UV radiation may, even in little doses, cause harm to the eyes and skin. • Changes or modifi cations made to this system without the consent of Puretec could render the system unsafe for operation and may void the warranty.
  • Page 7 This appliance meets the domestic water treatment appliance Standard AS/NZS 3497 for the following water treatment process: Category Treatment type Function Pass Will remove or II(a) Bacteria inactivate bacteria Removal AS/NZS 3497 WM 040223 Global-Mark.com.au Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 8: Water Quality

    UV system. These water quality parameters can be tested by your local Puretec dealer, or by most private analytical laboratories. Proper pre-treatment is essential for the UV system to operate as intended.
  • Page 9 Controller Lamp Cord Top Bolt & Wire Form Lamp Power Cord Sleeve O-Ring Cool Touch Fan Plug Sensor Chamber O-Ring Flow Meter Sensor Bottom Bolt (includes screw) Sleeve Removal Tool Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 10 Installation Diagram Fig. 2 - Installation Diagram Maximum 1820 mm 1220 mm Clearence for lamp removal. OUTLET 1830 mm INLET 250 mm (L) x 1” (Dia) Minimum 300 mm 10 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 11 Monitors fl ow to provide real time dose (UV exposure) Flow Meter Sensor Flow Sensor must be installed in this orientation with the LED facing up. Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 12 Dimensions Fig. 3 - RI-NSFA-2K Dimensions Measurements are shown in mm. 12 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 13 Dimensions Fig. 4 - RI-NSFA-4K Dimensions Measurements are shown in mm. Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 14 Fig. 5 - RI-NSFA-6K Dimensions Measurements are shown in mm. 14 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 15 Fig. 6 - RI-NSFA-11K Dimensions Measurements are shown in mm. Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 16: Pipe Lengths

    Note: The fl ow meter sensor must be mounted in the following orientation with the LED facing up. Ensure all air is purged from the piping and fl ow meter sensor. All straight length to the fl ow meter sensor must be 1.00" in diameter. 16 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 17: Installation

    • Make all necessary plumbing connections refer to Fig. 2 Installation Diagram. • Never connect PVC pipe directly to the unit. The outlet pipework within 1 metre should be metal or polyethylene. Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 18 Note: Ensure chamber is installed with green arrows pointing upwards. To connect the Flow meter sensor, apply three loops of thread seal tape to the NPT inlet thread. 18 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 19 Note: NO NOT over tighten as excessive force may damage fi ttings. Hand tighten the locking nut. Note: the LED must face up. Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 20 Note: DO NOT rotate the sleeve or touch the glass with bare hands. Use cotton gloves to handle the sleeve. 11. Wet the O-ring with water and place over the top end of the sleeve. 20 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 21 15. Install the UV lamp by rotating it into the sleeve assembly, ensuring to rotate the lamp completely. Note: DO NOT touch the glass with bare hands, use cotton gloves. Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 22 Note: The outlet must be protected by a ground fault circuit interrupter (GFCI). IMPORTANT! A er installing the UV lamp or sleeve the cleaning procedure MUST be performed. 22 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 23: Cleaning Procedure

    Reconnect the controller without the UV sensor. Shut off the water supply. Open an upstream faucet to release the pressure. Press the pressure button to release the pressure from the cartidges. Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 24 Remove fi lter housing(s) using sump wrench. Remove cartridges. Puretec recommends fl ushing the pipe work with a suitable sanitiser such as Puretec TankSafe™ (for dosage refer to TankSafe™ product instructions) or with 2 cups (500ml) of a household bleach solution. This solution should be le in the pipework for at least an hour, preferably overnight.
  • Page 25 5 minutes). 11. Press the pressure button to purge air and to complete the cleaning procedure. Disconnect the controller, then connect the UV sensor from the blue jack. Reconnect the controller. Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 26: Maintenance

    UV lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced a er 18,000 hours of continuous operation (approximately two years) in order to ensure adequate performance. Close all faucets and the water supply. 26 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 27 Drain the water from the UV system. Close the water inlet a er the water is drained. Pinch the wire form to release the lamp connector. Remove the lamp connector. Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 28 Remove the UV sensor from the unit. Submerge the end of the sensor in commercial scale remover for 30 minutes. Clean the sensor with a cotton swab and spray with water. Re-connect the sensor. Commercial Scale Remover 28 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 29 If the sleeve cannot be cleaned, it must be replaced. Prerequisites: • Shut off the water supply and drain all lines. • Remove the UV lamp (see "Replacing The Lamp' instructions). Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 30 Insert the sleeve removal tool into the bottom of the sleeve. Gently pry the sleeve upward until it becomes loose. Note: Place a bucket under the UV chamber to catch any water spillage. 30 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 31 (the bottom O-ring may fall during the sleeve removal process). Clean the sleeve with a cloth soaked in Puretec UV Sleeve Cleaner (SC1000), and rinse with water. Note: If the sleeve cannot be cleaned completely or it is scratched or cracked, then replace the sleeve as this will reduce the eff...
  • Page 32 10. Install a new lubricated O-ring over the top end of the sleeve. 11. Connect the sleeve bolt to the top of the chamber. 12. Remove the sleeve bolt at the bottom of the chamber. 32 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 33 Repeat on the other side. Disconnect the controller to the system. Replace the fuse. Caution: Double pole / Neutral fusing Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 34: Operation

    When the alarm is due to any other issue, the mute button will silence the audible alarm for 24 hours. A er installing a new lamp, press and hold for fi ve seconds to reset Lamp New Lamp timer. 34 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 35 UV dose is below minimum required, see Low UV Alarm section. Flow meter sensor Low UV Alarm fl ow Flow Meter operating failure; service or meter dose calculation normally. replace sensor. not active. Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 36 Operation Low UV Alarms 36 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 37: Troubleshooting

    Detect Flow Sensor not detecting fl ow. Increase fl ow rate through meter. Flow Meter Sensor red Flow Meter requires maintenance or status LED. Flow Meter Sensor not functioning. replacement. Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 38: Individual Model Specifi Cations

    Audible Alarm Mute Button: New Lamp Button: Lamp Age Indicator: Lamp Operation Indicator: Controller Operation Indicator: Solenoid Operation Indicator: Fan Operation Indicator: Sensor Reading Indicator: Certifi cations AS/NZS 3497 WM 040223 38 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 39 Audible Alarm Mute Button: New Lamp Button: Lamp Age Indicator: Lamp Operation Indicator: Controller Operation Indicator: Solenoid Operation Indicator: Fan Operation Indicator: Sensor Reading Indicator: Certifi cations AS/NZS 3497 WM 040223 Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 40 Audible Alarm Mute Button: New Lamp Button: Lamp Age Indicator: Lamp Operation Indicator: Controller Operation Indicator: Solenoid Operation Indicator: Fan Operation Indicator: Sensor Reading Indicator: Certifi cations AS/NZS 3497 WM 040223 40 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 41 Audible Alarm Mute Button: New Lamp Button: Lamp Age Indicator: Lamp Operation Indicator: Controller Operation Indicator: Solenoid Operation Indicator: Fan Operation Indicator: Sensor Reading Indicator: Certifi cations USEPA UVDGM 2006 Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 42 210 Watts 210 Watts Port Size Combo Combo Combo Inlet and outlet 1¼ " NPT 1¼ " NPT 1¼ " NPT 2" MNPT 1" FNPT 1" FNPT 1" FNPT 42 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 43: Warranty

    Puretec is renowned for its quality and a er-sales support so if you have any issues please call 1300 140 140 (AU) or 0800 130 140 (NZ). To make a warranty claim, contact us directly or the place of original purchase.
  • Page 44 44 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 45 Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...
  • Page 46 46 Installation & Operation Manual Copyright © Puretec Pty Ltd 2022...
  • Page 47 Copyright © Puretec Pty Ltd 2022 Puretec Radfire RI-NSFA Series...