Do you have a question about the XP10000E and is the answer not in the manual?
Questions and answers
Robert Lee Inman
May 12, 2025
generator wont start no fire in spark plug replaced plug still no spark
1 comments:
Mr. Anderson
May 20, 2025
A possible cause of no spark in the spark plug after replacement could be that the spark plug is fouled due to the choke being left on too long during starting attempts. This can happen if the engine dies and the choke remains in the left (closed) position. The fouled plug may need to be cleaned.
This answer is automatically generated
Robert Lee Inman
May 11, 2025
what is proper oil level
1 comments:
Mr. Anderson
May 20, 2025
The proper oil level for the PowerMax XP10000E is to fill the oil up to the top of the oil filler neck. Check the level by inserting the dipstick into the filler neck without screwing it in.
Page 1
XP10000E Gasoline Powered Generator Owner’s Manual IIS Customer Service or call 1-800-382-8273 (#239) Monday –Friday 6am to 7pm Product Support (Product: information, application, service info & warranty questions) or call 1-800-382-8273 (#239) Monday –Friday 6am to 7pm This manual provides information regarding the operation and maintenance of these products.
Page 2
The generator is a potential source of electrical shock if misused. Do not expose the generator to moisture, rain or snow. Do not let the generator get wet, and do not operate it with wet hands. These labels warn you of potential hazards that can cause serious injury. Read them carefully.
SAFETY INFORMATION Read and understand this instruction manual before operating your generator. You can help prevent accidents by being familiar with your generator’s controls, and by observing safe operating procedures. Operator Responsibility Know how to stop the generator quickly in case of emergency. Under stand the use of all generator controls, output receptacles, and connections.
any spilled fuel has been wiped up before starting the generator. CONTENTS SAFETY INFORMATION……………………………………………………………..2 COMPONENT IDENTIFICATION…………..…………………………………….…4 WATTAGE REFERENCE CHART……..………………………………………….….7 SPECIFICATIONS…………………………………………….………………….……9 WIRING DIAGRAM………………………………………………………….……..…10 ASSEMBLY………………………………………………………..……………….……11 PRE-OPERATION CHECK……………………………………………………...…….11 STARTING THE ENGINE/STOPPING THE ENGINE………………..…….………12 OPERATING INSTRUCTIONS………………………………………….…….……...13 MAINTENANCE…………………………………………..…………………….………16 STORAGE…………………………………………………..……………………………19 TROUBLESHOOTING…………………………………..……………………………..21 WARRANTY SERVICE INFORMATION……………………………..………….…..22...
Page 6
Engine Key To start and stop the engine. Key position: OFF: To stop the engine. Key can be removed / inserted. ON: To run the engine after starting. START: To start the engine by operating the starter motor. Do not turn the key switch to START position when the engine is running to prevent damage of starting motor.
Page 7
Change the Voltage Selector Switch after turning the AC circuit breaker to OFF. The generator may be damaged. Ground Terminal The generator ground terminal is connected to the frame of the generator, the metal non-current-carrying parts of the generator, and the ground terminals of each receptacle. DC Receptacle The DC receptacle may ONLY be used for charging 12 volt automotive type batteries.
WATTAGE REFERENCE CHART Electric equipment, especially engine produces strong current when being started. The table below offers reference when you connect those installations to generator. Tool or Appliance Rated* (Running) Watts Additional Surge (Starting) Watts Essentials Light Bulb-75 watt Deep Freezer Sump Pump 1200 Refrigerator/Freezer-18 Cu.
SPECIFICATIONS Model XP10000E Frequency 60 HZ Generator Max.AC Output 10000 Watt Rated AC Output 8000 Watt Run Time 8 hour Model XP16HPE Type Air Cooled, OHV, 4-Stroke Displacement 419 cc Output 16.0 HP / 3600 rpm Fuel Unleaded Gasoline Engine Fuel Tank Capacity 8.3 Gallon...
ASSEMBLY Wheel Kit Installation 1 Install the axle assembly on the generator. 2 Install the two wheels on the axle shaft using the washers and flange nuts. 3 Install the two stands on the under frame using the flange nuts. Starter Cables Connection 1 Route the starter cable under the tank.
Page 12
Always check the API SERVICE label on the oil container to be sure it includes the letter SJ. SAE 10W-30 is recommended for general, all-temperature use. Other viscosities shown in the chart may be used when the average temperature in your area is within the indicated range. 1 Remove the oil filler cap and wipe the dipstick clean.
STARTING THE ENGINE / STOPPING THE ENGINE Starting the Engine Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to start if a load is connected. 2 Turn the fuel valve lever to the ON position. 3 The choke will be closed if the engine is cold, pull the choke rod out to the CLOSED position.
Page 14
Before connecting an appliance or power cord to the generator: Make sure that it is in good working order. Faulty appliances or power cords can create a potential for electrical shock. If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off immediately.
Page 15
DC Operation The DC terminals may ONLY be used for charging 12 volt automotive type batteries. Connecting the battery cables: 1 Before connecting the battery charging cables to a battery that is installed in a vehicle, disconnect the vehicle ground battery cable from the battery negative ( -...
Disconnect the other end of the negative ( - ) battery cable from the battery negative ( - terminal. Disconnect the other end of the positive ( + ) battery cable from the battery positive ( + terminal. 5 Reconnect the vehicle ground battery cable to the battery negative ( -...
Page 17
designed purpose. Sustained high-load or high-temperature operation, or use in unusually wet or dusty conditions, will require more frequent service. Before First Every3 Every6 Every REGULAR SERVICE PERIOD ( ) each month months months year or ITEM or 20 or 50 or 100 Performed at every indicated month or Hrs.
Page 18
Air Cleaner Service A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas. Never run the generator without the air filter. Rapid engine wear will result. Unsnap the air cleaner cover clips, remove the air cleaner cover, and remove the element.
Fuel Sediment Cup Cleaning The sediment cup prevents dirt or water, which may be in the fuel tank from entering the carburetor. the engine has not been run for a long time, the sediment cup should be cleaned. Turn the fuel valve lever to the OFF position. Remove the sediment cup, O-ring, and filter. 2 Clean the sediment cup, O-ring, and filter in nonflammable or high flash point solvent.
bowl. Fill with fresh gasoline and add gasoline conditioner. Drain 2 months to 1 the carburetor float Drain the fuel sediment cup. year Fill with fresh gasoline and add gasoline conditioner. Drain the carburetor float bowl. Drain the fuel sediment cup. Remove the spark plug.
Page 21
EASY START INSTRUCTION 1) Apply at least 1 gallon of gas or until gas gauge shows over 2 gallons full. 2) Apply engine oil (10-30w) until you can see oil surface at the top. Apply oil cap, low oil kill switch is know activated. 3) Turn on/off switch to ON position (located on control panel).
Page 22
GENERATOR ASSEMBLY AND MOUNTING Generator is supplied with a wheel kit. If you want to install the wheel kit on your unit, please follow the instructions below. If you will not be using the wheel kit, skip this section. 1. Place the bottom of the generator cradle on a flat, even surface. Temporarily place unit on blocks to ease assembly.
Need help?
Do you have a question about the XP10000E and is the answer not in the manual?
Questions and answers
generator wont start no fire in spark plug replaced plug still no spark
A possible cause of no spark in the spark plug after replacement could be that the spark plug is fouled due to the choke being left on too long during starting attempts. This can happen if the engine dies and the choke remains in the left (closed) position. The fouled plug may need to be cleaned.
This answer is automatically generated
what is proper oil level
The proper oil level for the PowerMax XP10000E is to fill the oil up to the top of the oil filler neck. Check the level by inserting the dipstick into the filler neck without screwing it in.
This answer is automatically generated