The TCELL925 and TCELL95-W are extended life cells designed for pools up to 25,000 gallons. When replacing an existing T-CELL-9, GLX-
CELL-9, TCELL925 or TCELL925-W, no re-configuration is necessary.
You must configure your controller for use with the TCELL925 or TCELL925-W chlorinator cell before attempting to operate. Incorrect
configuration will cause inaccurate salt readings, improper operation, and possible system shutdown. The TCELL925 and TCELL925-W are
compatible with the following models only and will NOT work with earlier versions:
• AQR (AquaRite - all 2009 or later) - firmware version 1.5 or later
• AQR-PRO (AquaRite Pro) - operating with firmware 1.10 or later
• PL-P-4 (ProLogic P4) - operating with firmware 4.10 or later
• PL-PS-x (ProLogic PS) - operating with firmware 4.10 or later
• AQR900 series - all
Connecting to an AQR or AQR900:
1. Slide the Main Switch to the "Auto" position.
2. Push the Diagnostic button repeatedly until "t-xx" appears on the display ("t-15" is the factory default).
3. To change cell type, slide the Main Switch from "Auto" to "Super Chlorinate" and back to "Auto". Repeat this process until the "t-9" is
displayed.
4. Push the Diagnostic button to exit.
Connecting to an AQR-PRO:
1. Verify that the firmware version is 1.10 or greater by pushing the "Info" button, then">" repeatedly until the firmware revision is shown.
If the firmware version is less that 1.10, the TCELL925 cannot be used.
2. Access the Settings Menu by pushing the "Settings" button.
3. Push ">" until Chlor. Config is displayed, then push "+".
4. Push ">" repeatedly until "Cell Type" is displayed.
5. Push "+" or "-" until "T-CELL-9" is displayed.
6. Exit Settings Menu by pushing the "Info" button.
Connecting to a PL-P-4 or PL-PS-x:
1. Verify that the firmware version is greater than 4.10 by entering the Diagnostic Menu and repeatedly pushing the ">" until the Main
Firmware revision is shown. If the firmware version is less that 4.10, the TCELL925 cannot be used.
2. Enter the Configuration Menu.
3. Push ">" until Chlor. Config is displayed, then push "+".
4. With the Chlorinator Enabled, push ">" repeatedly until "Cell Type" is displayed.
5. Push "+" or "-" until "T-CELL-9" is displayed.
6. Exit Settings Menu by pushing the "Menu" button.
TCELL925
TCELL925-W
MENU SETTING MAY BE REQUIRED!
Hayward Industries
400 Connell Drive, Suite 6100
Berkeley Heights, NJ 07922
Phone: (908) 355-7995
www.hayward.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
092631 RevA

Advertisement

loading

Summary of Contents for Hayward TCELL925

  • Page 1 TCELL925-W MENU SETTING MAY BE REQUIRED! The TCELL925 and TCELL95-W are extended life cells designed for pools up to 25,000 gallons. When replacing an existing T-CELL-9, GLX- CELL-9, TCELL925 or TCELL925-W, no re-configuration is necessary. You must configure your controller for use with the TCELL925 or TCELL925-W chlorinator cell before attempting to operate. Incorrect configuration will cause inaccurate salt readings, improper operation, and possible system shutdown.
  • Page 2 Hayward is a registered trademark and AquaRite, AquaRite Pro, and ProLogic are trademarks of Hayward Industries, Inc. © 2016 Hayward Industries, Inc. All other trademarks not owned by Hayward are the property of their respective owners. Hayward is not in any way affiliated with or endorsed by those third parties.

This manual is also suitable for:

Tcell925-w