OPERATING INSTRUCTIONS
CO2 GAS ALARM GX-D500P
Prof. CO2 warning device for
Carbon dioxide from technical systems
item no. 300263
www.elektrotechnik-schabus.de

Advertisement

loading

Summary of Contents for Elektrotechnik Schabus GX-D500P

  • Page 1 OPERATING INSTRUCTIONS CO2 GAS ALARM GX-D500P Prof. CO2 warning device for Carbon dioxide from technical systems item no. 300263 www.elektrotechnik-schabus.de...
  • Page 2 This is a translation from the German original, we are not liable for errors in the automatic translation. 1. Scope of Delivery ⋅ 1 GX-D500P CO2 warning device ⋅ 2 meter hose (item no. 21002) ⋅ 1 dust filter (item no. 300259) ⋅...
  • Page 3 ⋅ All locations are characterized by being connected to the public low- voltage network. 3. Intended Use The GAS ALARM GX-D500P is a carbon dioxide alarm device for resi- dential and similar use with an integrated NDIR sensor. An LCD display provides constant information about the operating status and the roun- ded percentage of the CO2 concentration measured in the monitored room, which is either thermally demanding or heavily loaded with dust.
  • Page 4 4. Assembly Instructions The GAS ALARM GX-D500P may only be installed on a wall in dry indoor areas. The „middle height“ mounting position is cho- sen so that the display is easy to read when standing. This also ensures that the warning device functions correctly.
  • Page 5 4.3 terminals Relais Ö Ö4 Ö3 Ö2 Ö1 NO 5 A / NC 3 A 230 VAC L, N and PE - clamps are connected 2 each to facilitate bridges to the relay, relay contacts: G = common contact, Ö = NC / opener, S = NO / closer 4.4 Laying the hose to thermally demanding rooms First of all and valid for all applications: ⋅...
  • Page 6 The minimum hose length of 1000mm between outlet (hole) and outlet (GX-D500P) must be obser- ved in hot/cold rooms. For shortening, the thickness of the wall and an overhang of the hose of 5 to 10 mm are added, in the drawing on the right it is e.g.
  • Page 7 CO2. 4.5 Hose routing and attachment If the GX-D500P is mounted vertically above the exit hole, there is no need to attach or route the hose, unless it is a public space. If there is likely to be public traffic, we recommend covering it with a commercially available cable duct.
  • Page 8 (can) stay permanently. Like the GX-D500P itself, the dust filter is only permanently suitable for temperatures from +10°C to +50°C. Blow regularly to remove dust from the dust filter and avoid moisture/moisture on the filter.
  • Page 9 For your safety, we recommend that you regularly check that the acoustic alarm device is working properly using the test button! All three LEDs light up and the two relays Re1 and Re2 drop out. 5.1 Alarm The alarm when the alarm threshold is reached is given with a loud pe- netrating tone from a piezo sounder, the display lighting and the red LED flashing, and the alarm relay Re1 dropping out.
  • Page 10 5.3 Behavior in the event of an alarm Ventilate the room and ensure that no further carbon dioxide can escape by switching off/blocking the CO2 source. Inform other people and ask them to leave the room. 5.3.1 Keep calm and open all doors and windows, finish all use of incinerators.
  • Page 11 8, display page (05). The term „error“ and a number appear. Please give this number to the techni- cal support of Elektrotechnik Schabus, who will find a solution together with you. (+49 (0) 8036 674 97 90) 6.2 Interpretation of technical faults using the yellow LED...
  • Page 12 7. MAINTENANCE: Re-calibration by zero point adjustment 7.1 In principle, the CO2 warning device GX-D500P requires little main- tenance. Dust it from time to time, using only dry cloths. Please do not blow or suck on the hose. 7.2 Reset the zero point regularly or when necessary. Every sensor is...
  • Page 13 type label module screw NDIR-Sensor membrane 4 IR-LEDs under the membrane module plug module screw calibration button 7.3.2 Gently pry with a small screwdriver unplug the connector from the sensor module. Switch at it a few times the sides around the connector to get out as straight as possible.
  • Page 14 The zero point calibration is now complete. 7.3.9 Now reinstall the sensor module to the GX-D500P by doing the reverse. Unplug the USB cable, unscrew its module with the two M2 screws on its place and connect it back to the bottom part of the war- ning device.
  • Page 15 8. Display Information When starting up, i.e. applying mains voltage, the display welcomes you with our name and the device type. After this time, the self-tests and the initialization of the software and sensor start. The display shows for about 3 minutes: (00) Wait...
  • Page 16 9. Tecnical data Operating voltage: 100 - 240 V AC / 50-60 Hz Power consumption: max. 8 VA, depending on the operating status Installation: only upright, surface-mounted, permanent instal- lation Sensor technology: internal infrared / NDIR sensor up to 50,000 ppm Sensor resolution / accuracy: ±...
  • Page 17 10. General Elektrotechnik Schabus GmbH & Co. KG is not liable for damage and/or loss of any kind, such as individual or consequential damage, resulting from the gas detector not giving an alarm signal despite an increased gas concentration. In order to always be able to guarantee perfect functionality, you should have the sensor checked after 5 years at the latest and replaced after 8 years for your own safety.
  • Page 18 We grant a statutory warranty on your electronic product from Elektro- technik Schabus for material defects and quality defects from the date of purchase. Elektrotechnik Schabus will repair or replace your device free of charge under the following conditions: If there is a statutory warranty, the device must be sent in with the fol-...
  • Page 19 10.5 environmental information The production of the product you have purchased required the extrac- tion and use of natural raw materials. It may contain substances that are hazardous to health and the environment. To avoid spreading these substances in your area and to save natural resources, we ask you to use the appropriate return systems.
  • Page 20 Elektrotechnik Schabus GmbH & Co. KG +49 (0) 80 36 / 67 49 79 - 0 Baierbacher Str. 150 +49 (0) 80 36 / 67 49 79 - 79 D-83071 Stephanskirchen MAIL info@elektrotechnik-schabus.de www.elektrotechnik-schabus.de 300263-220808-EN-SCHABUS...