Page 1
-20dB Magnetic loop measuring device For optimal use of the loop measuring device, hold your device vertically. Pour une utilisation optimale du mesureur de boucle magnétique, tenez votre appareil verticalement. Polycarbonate BM-Control USER GUIDE H11388 - Version 1 / 05-2022...
Page 2
This ergonomic instrument has two calibrated measuring functions and two types of filters for removing background noise and magnetic field intensity. Using a headset, the BM-Control allows you to listen to and control the installation of your magnetic loop. 2 - Packaging content •...
Page 3
Magnetic loop measuring device AUDIOPHONY PUBLIC ADDRESS English MADE IN FRANCE 4 - Description Distributed by HITMUSIC S.A.S Zone Cahors Sud 46230 FONTANES - FRANCE Emballage Color-coded display of the field strength On/Off indicator Battery-low indicator >+8 > - 12...
Page 4
English BM-Control - Magnetic field strenght meter 5 - Measerement functions (-20db) Measuring range for background noise Increases the sensitivity of the device. Used to detect stray magnetic fields or a magnetic pollution zone. We advise to carry out your measurements with a...
Page 5
(end customer). This statement will certify that the installation complies with the restrictions of IEC-60118-4 (if measurements and settings are good). Audiophony Public Address has created a compliance report to gather all your measurements, you can download the model on the BM-Control product page: https://audiophony-pa.com/en/produit/bm-control/ 5.2 Step-by-step instructions...
Page 6
English BM-Control - Magnetic field strenght meter Notes and requirements of Standard 60118-4 The standard states that the signal level in the loop area should not vary by more than ± 3dB. Once confirmed, the signal level from the normal building program should peak at 0 dB as referenced at 400mA/m.
Page 7
AUDIOPHONY PUBLIC ADDRESS English Procedure for receiving magnetic loops Thanks to the law of February 2005, establishments receiving the public (ERP) are gradually equip- ping themselves with magnetic induction loops in order to facilitate listening for people with hearing difficulties. To be effective these systems must be carefully calibrated to verify that the installation has been made in compliance with standard EN60118-4.
English BM-Control - Magnetic field strenght meter Certificate of conformity to IEC 60118-4 standard Definition of the listening area for the hearing impaired Area of use Standard: 1m to 1.4m Standard: 1m to 2m Sketch of the room and listening area (indicate scale and dimensions) Indicate 4 to 6 points (A to F) inside the room to perform the measurements –...
Page 9
La société AUDIOPHONY® apporte le plus grand soin à la fabrication de ses produits pour vous garantir la meilleure qualité. Des modifications peuvent donc être effectuées sans notification préalable. C'est pourquoi les caractéristiques techniques et la configuration physique des produits peuvent différer des spécifications et illustrations présentées dans ce manuel.
Need help?
Do you have a question about the BM-Control and is the answer not in the manual?