Water connection (Steam Model only)
WATER SUPPLY REQUIREMENTS
Cold water faucet MUST be installed within 42 inches
(107 cm) of your dryer's water inlet. The faucet MUST be
3/4 inch (1.9 cm) with threading for laundry hose con-
nection. Water pressure MUST be between 30 and 120
psi. Your water department can advise you of your water
pressure.
1 Turn off COLD water supply to washer.
2 Remove COLD inlet hose from COLD water supply
and inspect for rubber washer. Replace washer if it
is torn or worn out.
RUBBER WASHER
MUST BE PRESENT
AND UNDAMAGED
COLD INLET HOSE
TO WASHER
3 Momentarily turn on COLD supply and run some
water into a bucket or container to clear any
contaminants in the line.
4 Remove hose kit from dryer drum and inspect hose
couplings for proper placement of rubber washers.
RUBBER WASHERS
MUST BE PRESENT
INSTALLATION INSTRUCTIONS