HOT WATER DISPENSER
Installation & Operating Guide
Read all instructions thoroughly. Keep this guide for future reference.
Proof of purchase is required for Warranty. Staple receipt or proof of
purchase to this manual for easy reference. Warranty non-transferable.
NOTE: Do not plug appliance into power supply if tank is empty.
Record important Hot Water Dispenser information here
Model Number*
WH-1500
WARNING:
• This tank is not compatible with InSinkErator faucets
• Do not install in homes with well water
• Westinghouse tanks are vented hot water dispensers and are designed to be used only
with open vent faucets (faucet valve is placed before the tank, creating an "open vent" which
causes no pressure build up inside the tank)
• Westinghouse tanks will have longer life if a water fi lter with scale inhibitor is attached.
• A drain pan, plumbed to an appropriate drain or outfi tted with a leak detector, should be
used in those applications where any leakage could cause property damage
Serial Number*
(1)
IM-WH-1500-221

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WH-1500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Westinghouse WH-1500

  • Page 1 • Westinghouse tanks will have longer life if a water fi lter with scale inhibitor is attached. • A drain pan, plumbed to an appropriate drain or outfi tted with a leak detector, should be...
  • Page 2: Hot Water Dispenser

    HOT WATER DISPENSER COMPONENTS: When you purchase the Westinghouse Water tank, contents include: 1. Quick-connect fi tting for water inlet tube 2. Tank 3. 1/4” or 3/8” Hose Clamp 4. Connector/Reducer adapter for 1/4” or 3/8” center outlet tubing 5. 5cm Stainless Steel Tube 6.
  • Page 3 Personal Injury: This tank is a non-pressurized tank. DO NOT modify this system. DO NOT close vent tube or connect other type dispensers or valves to the tank. Use only the Westinghouse dispenser faucet supplied. Use only parts provided. Contact a certifi ed repair person for repairs or replacement components.
  • Page 4: Electrical Requirements

    ELECTRICAL REQUIREMENTS Recommended Ground Method For your personal safety, the hot water dispenser is equipped with a power supply cord having a 3-prong ground plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong, ground type outlet, grounded in accordance with all local codes and ordinances.
  • Page 5 IMPORTANT: Observe all governing codes and ordinances. Faucet may be installed in spray hose opening in sink or drilled hole. If drilling another hole is needed, the 13⁄8"/35mm maximum diameter hole is required. Tank must be mounted vertically Quick - connector fittings connects to cold water supply line.
  • Page 6: Typical Installations

    Instructions are for both single or dual faucets. Faucet line connects to the cold water supply with quick-connect fitting or compression fitting (not supplied) Dual Handle Faucet shown Connect silicone hose to the center outlet tube on top of tank. Tighten Faucet line connects to filtered cold the connection with ¼”...
  • Page 7 IMPORTANT INFORMATION - This dispenser is equipped with a self re-setting thermal fuse. Turn the thermostat to OFF position and fi ll tank with water before plugging the power cord from the tank into an electrical outlet. If tank is empty and the thermostat set in the ON position when the power cord is connected, the self re-setting fuse in the heater control will disconnect the current to the heater after approximately one minute, thus protecting the heater from a “dry start”...
  • Page 8: Care And Use

    CARE AND USE Electric Shock Hazard. To prevent electrical shock, disconnect power before servicing unit. Use only a properly grounded and polarzed electric outlet. ADJUSTING THE THERMOSTAT Factory temperature pre-set F 5 F. To reset the thermostat to that setting, turn the indicator two notches to the right of vertical.
  • Page 9: Troubleshooting

    TROUBLESHOOTING PROBLEM POSSIBLE CAUSE WHAT TO DO Water and steam spits • Unit is boiling. • Activate faucet lever to release some water from forcefully from spout the tank. May be normal during initial setup. without turning on the • Adjust water temperature using dial on tank front. dispenser faucet.
  • Page 10 Customer Service: , WESTINGHOUSE, and Joneca Company, LLC. INNOVATION YOU CAN BE SURE 4332 E. La Palma Avenue Anaheim, California 92807 OF are trademarks of Westinghouse Telephone: 714.993.5997 Fax: 714.993.2126 Electric Corporation. Used under Website: www.Joneca.com license by Joneca Company, LLC.