Sharp MX-TMX1 Service Manual page 57

Table of Contents

Advertisement

20 October 2010
TM-152
Fault Code TM-151, indicates that the Interlock switch is faulty.
Initial Actions
Check fuse F2 on Transformer.
Enter the Service mode and check the Trimmer voltmeter.
Power ON and Power OFF the Trimmer (make sure that the Top cover interlock, and
the External Interlock Device interlock is interlocked).
Procedure
Measure the Interlock switch S9 and S10, and make sure that they are OK. Are all two switches OK?
Y
N
Replace faulty switch.
Measure for continuity between J14-18 and J14-19, between J25-3 and J25-4. Is there continuity in both cables?
Y
N
Replace wire harness.
Replace PCB.
TM-201
Fault Code TM-201, indicates that during Run, the Infeed sensor (TM-Q13), was not blocked within
timeout.
Initial Actions
Check fuse F2 on Transformer.
Make sure that the Infeed sensor (TM-Q13) is installed correctly.
Procedure
Enter the Service mode and select Infeed sensor (TM-Q13) in check sensors. Activate, then deactivate, the TM-Q13. The
Infeed sensor (TM-Q13) indicates :1 when the sensor is activated and :0 when the sensor is deactivated.
Y
N
Go to TM-016 fault code.
1. Make sure that the Exit guide bracket is installed as high as possible.
2. Make sure that nothing interferes with the paper path.
TM-202
Fault Code TM-202, indicates that at "initialization" or during Run, the Infeed sensor (TM-Q13), was
blocked exceeding timeout.
Initial Actions
Check fuse F2 on Transformer.
Make sure that the Infeed sensor (TM-Q13) is installed correctly.
Procedure
Enter the Service mode and select Infeed sensor (TM-Q13) in check sensors. Activate, then deactivate, the TM-Q13. The
Infeed sensor (TM-Q13) indicates :1 when the sensor is activated and :0 when the sensor is deactivated.
Y
N
Go to TM-016 fault code.
Make sure that nothing interferes with the paper path.
FAULT CODE DESCRIPTIONS