Willoughby Industries WAF-5406 Series Installation & Operation Manual

Aquafount 54" 360 solid surface washfountain electronic/pneumatic

Advertisement

Quick Links

WAF-5408
Rev. 9/2021
Willoughby Industries, Inc.
5105 West 78th Street
Indianapolis, IN 46268
Toll Free:
(800) 428-4065
Local:
(317) 875-0830
Fax:
(317) 875-0837
www.willoughby-ind.com
Installation &
Operation Manual
WAF-5406 Series
WAF-5408 Series
Aquafount
54" 360°
®
Solid Surface Washfountain
Electronic/Pneumatic

Table of Contents

Pre-Installation Information �������������������������������������2
Physical / Rough-in Dimensions ����������������������������� 3
Required Installation Supplies �������������������������������� 5
Parts List ����������������������������������������������������������������6
Exploded-view Drawing ������������������������������������������7
Hardware Identification ������������������������������������������8
Installation Instructions ���������������������������������������������
Step 1: Pedestal Mounting ��������������������������������� 9
Step 2: Head and Basin Assembly ������������������ 10
Step 3: Drain Assembly ����������������������������������� 11
Step 4A: Connections for Infrared/Piezo
Actuators �������������������������������������������12
��������������������������������������������������������������������������13
Step 5: Final Assembly ������������������������������������14
JACO Fitting Instruction ����������������������������������������15
Adjustable Mixing Valve Installation ��������������������� 16
Infrared Sensor Installation Instructions ��������������� 17
Pneumatic Valve Operation Details ���������������������� 18
Liquid Soap Specification and Maintenance ��������� 19
Care and Maintenance �����������������������������������������20
Troubleshooting ��������������������������������������������������������
Infrared Sensors �����������������������������������������������21
Electronic Valves ����������������������������������������������22
Pneumatic Valves ���������������������������������������������23
Drawings �������������������������������������������������������������������
General Dimensions and Rough-in Detail �������� 24
Valve Details �����������������������������������������������������25
Miscellaneous Details ���������������������������������������34
Warranty ���������������������������������������������������������������38
MADE IN THE U.S.A.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WAF-5406 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Willoughby Industries WAF-5406 Series

  • Page 1: Table Of Contents

    Installation & Operation Manual WAF-5406 Series WAF-5408 Series Aquafount 54" 360° ® Solid Surface Washfountain Electronic/Pneumatic Table of Contents Pre-Installation Information �������������������������������������2 Physical / Rough-in Dimensions ����������������������������� 3 Required Installation Supplies �������������������������������� 5 WAF-5408 Parts List ����������������������������������������������������������������6 Exploded-view Drawing ������������������������������������������7 Hardware Identification ������������������������������������������8...
  • Page 2: Pre-Installation Information

    When installing the Willoughby Industries' WAF-5406/5408 Series washfountain system: When installing the Willoughby Industries’ WAW, WAF, or WWF series washfountains or lavatory deck systems: Before Step 1 of the installation instructions, ensure that rough-ins are in the correct location�...
  • Page 3: Physical / Rough-In Dimensions

    Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Physical / Rough-in Dimensions- WAF-5406 Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 3...
  • Page 4 Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Physical / Rough-in Dimensions- WAF-5408 Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 4...
  • Page 5: Required Installation Supplies

    Supply piping • Silicone caulk • Plumbers putty WARNING: Willoughby Industries does not assume any responsibility for personal injury or damage to equipment due to an improperly installed WAF-5406/5408 Series washfountain. Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev.
  • Page 6: Parts List

    Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Parts List DESCRIPTION PART NUMBER (P/N) PART NUMBER (P/N) ITEM - 6-STATION - 8-STATION 54" FULL-ROUND BASIN - SOLID SURFACE 800540C-XX* 800540C-XX* TOP COVER - SOLID SURFACE...
  • Page 7: Exploded-View Drawing

    Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Exploded-view Drawing *WAF-5408 8-station unit shown Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 7...
  • Page 8: Hardware Identification

    Aquafount 360° Washfountain ® INSTALLATION INSTRUCTIONS Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Hardware Identification HARDWARE Identification Chart Visit our website at http.//www.willoughby-ind.com 2210 West Morris Street • P.O. Box 21217 • Indianapolis, IN 46221 (317) 638-2381 • Fax: (317) 638-6110 • (800) 428-4065 ©...
  • Page 9: Installation Instructions

    Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Installation Instructions Step 1: Pedestal Mounting Parts supplied: • Pedestal base assembly Note: Hardware for floor anchoring by others Unpack pedestal and inspect parts. Place pedestal at the desired poistion and mark anchor holes (anchors by others). Make sure that the intended anchor locations will provide adequate backing to support the installed washfountain.
  • Page 10: Step 2: Head And Basin Assembly

    Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Installation Instructions (cont.) Step 2: Valving and Basin Assembly Parts supplied: • Washfountain wash basin • Pedestal base assembly • Actuator housing assembly • 1/4"-20 X 1/2" security screws...
  • Page 11: Step 3: Drain Assembly

    Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Installation Instructions (cont.) Step 3: Drain Assembly Parts/Materials supplied: • Solid surface basin • Drain assembly (see diagram) • Plumbers putty (supplied by others) 1�) As shown on the diagram, apply a small (approx�...
  • Page 12: Actuators

    Aquafount 360° Washfountain ® · Valve Assembly Plug-In Transformer Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Terminal Block Plate 4’ x 3/8" multi-colored water lines Installation Instructions (cont.) · ¼-20 x ½” security screws · ¼-20 tinnerman nuts ·...
  • Page 13: Step 4B: Connections For Pneumatic Actuators

    INSTALLATION INSTRUCTIONS Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series STEP FOUR-B Installation Instructions (cont.) Connections for Pneumatic Actuators Parts supplied: Step 4B: Connections for Pneumatic Actuators · 4’ x 3/8" multi-colored water lines ·...
  • Page 14: Step 5: Final Assembly

    Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Installation Instructions (cont.) Step 5: Final Assembly Parts supplied: • Solid surface cover • Front access cover • Spacer tray • 1/4"-20 tinnerman nuts • 1/4"-20 X 1" security screws •...
  • Page 15: Jaco Fitting Instruction

    INSTALLATION INSTRUCTIONS Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series JACO Fitting Instruction JACO Fitting Instructions Note: It is not necessary to disassemble this fitting for application. Merely insert tubing to stop and tighten seal.
  • Page 16: Adjustable Mixing Valve Installation

    Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Adjustable Mixing Valve Installation INSTALLATION INSTRUCTIONS IS-P-e480 HydroGuard ® T/P Series e480 Lavatory Combination Valve Installation Instructions To Install Figure 1 NOTE: Installation should be in accordance with accepted plumbing practices.
  • Page 17: Infrared Sensor Installation Instructions

    Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Infrared Sensor Installation Instructions Willoughby Industries Infrared Lavatory Sensor Installation Instructions DETECTION AND ACTIVATION When the sensor detects a user, a slow flashing red light appears in the sensor window. After 1 to  2 seconds of detection, the light flashes rapidly and the sensor immediately activates the solenoid  valve to begin water flow. The solenoid valve remains open as long as the user is detected. The  solenoid  valve  turns  off  when  the  user  is  no  longer  detected.  The  sensor  is  set  to  activate  the ...
  • Page 18: Pneumatic Valve Operation Details

    Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Pneumatic Valve Operation Details Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 18...
  • Page 19: Liquid Soap Specification And Maintenance

    Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Liquid Soap Specification and Maintenance (For models with “LSD” option only) Liquid soap viscosity is measured in “cps” (centipoise). The liquid soap chosen to be used with Willoughby’s Liquid Soap Dispenser should be between 100cp and 2500cp.
  • Page 20: Care And Maintenance

    INSTALLATION INSTRUCTIONS Aquafount 360° Washfountain ® INSTALLATION INSTRUCTIONS Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Care and Maintenance Care and Maintenance Care and Maintenance Solid Surface Care Solid Surface Care Aquasurf ® surfaces may be easily cleaned using conventional cleaning agents such as an ammonia Surfaces may be easily cleaned using conventional cleaning agents such as an ammonia Aquasurf ®...
  • Page 21: Infrared Sensors

    360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Troubleshooting - Infrared Sensors I� Faucet does not function (red light does not appear when user steps in front of sensor) A� No power to sensor. Make certain that power is on. Check transformer leads and connections.
  • Page 22: Electronic Valves

    360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Troubleshooting - Electronic Valves The two most common reasons an electronic valve does not operate properly are: (1) lack of power or (2) lack of water pressure. The following steps should be used as a guide in identifying the problem of a malfunctioning electronic valve.
  • Page 23: Pneumatic Valves

    360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Troubleshooting - Pneumatic Valves I. Valve will not open or deliver water A. Check the plastic tubing that runs from the pushbutton actuator to the pneumatic valve for air leaks.
  • Page 24: General Dimensions And Rough-In Detail

    Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 24...
  • Page 25: Valve Details

    Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 25...
  • Page 26 Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 26...
  • Page 27 Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 27...
  • Page 28 Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 28...
  • Page 29 Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 29...
  • Page 30 Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 30...
  • Page 31 Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 31...
  • Page 32 Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 32...
  • Page 33 Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 33...
  • Page 34: Miscellaneous Details

    Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 34...
  • Page 35 Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 35...
  • Page 36 Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 36...
  • Page 37 Aquafount 360° Washfountain ® Installation & Operation Manual WAF-5406 Series / WAF-5408 Series Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev. 9/2021 www.willoughby-ind.com Page 37...
  • Page 38: Warranty

    Willoughby Industries, Inc� Willoughby Industries, Inc� shall not otherwise be liable under any indirect damages caused by defects in the repair or replacement thereof�...

This manual is also suitable for: