Download Print this page

zeeltronic VCDI-30 User Manual

Digital ignition control unit

Advertisement

Quick Links

www.zeeltronic.com
info@zeeltronic.com
updated 13.06.2008
program version: 000.070508
VCDI-30 DIGITAL IGNITION CONTROL UNIT
TECHNICAL DATA
Limit values:
- minimum revs
- maximum revs
- minimum supply voltage
- maximum supply voltage
- max. supply voltage for 1 minute
- current draw
- maximum continuous current for shift light output
- peak current for shift light output
Circuit is protected against reverse supply voltage (wrong connection).
Features:
- three inputs for magnetic pickups
- store and load function for 10 ignition curves
- shift light output
- external switch for changing ignition curve while riding
- easy and fast programming on the field, via hand held programmer
- programming while machine running - you can immediately see effects
- each curve can be set in 4 to 10 curve points
- advance/retard whole ignition curve
- three stage rev limit (retard timing, reduced spark, spark off)
- signal delay compensation
- instant monitoring of rev's and angle, via LCD(hand held programmer)
- fast processing for high accuracy - delays from 1us
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...)
USER MANUAL
- 1 -
200 RPM
20000 RPM
8 Volts
20 Volts
40 Volts
25 mAmp
1 Amp
5 Amp

Advertisement

loading

Summary of Contents for zeeltronic VCDI-30

  • Page 1 13.06.2008 program version: 000.070508 USER MANUAL VCDI-30 DIGITAL IGNITION CONTROL UNIT TECHNICAL DATA Limit values: - minimum revs 200 RPM - maximum revs 20000 RPM - minimum supply voltage 8 Volts - maximum supply voltage 20 Volts - max.
  • Page 2: Menu Organisation

    HOW TO ENTER MENU VCDI must be connected to power supply. Connect programmer to VCDI and wait few seconds for activation of programmer and then press enter. With pressing + or - you can move through menu and with pressing enter you can choose. You can exit menu with choosing Exit.
  • Page 3 Change IGNITION CURVE Enter menu and move to Ignition Curve with pressing + or - and then press enter . Now you are in submenu for setting ignition curve. Submenu organisation: Nr. of Points - number of ignition curve points (from 4 to 10) - first ignition curve point - second ignition curve point Exit Curve...
  • Page 4 5.2. Change PARAMETERS OF IGNITION CURVE POINT Move to point you want to change, with pressing + or - and then press enter . Now you can change rev point with pressing + or - (in 100 rpm steps) and then press enter .
  • Page 5 Set PULSE WIDTH It is output pulse width (duration) in us. It affect on CDI triggering. Recommended setting is 200us or 100us. Enter menu and move to Pulse Width with pressing + or - and then press enter . Now you can change pulse width with pressing + or - (in 100us steps) and then press enter .
  • Page 6 MONITORING Connect programmer to VCDI and wait few seconds for activation of programmer. Fist information displayed on the programmer is software version. With programmer you can watch revs, calculated advance ignition angle and TPS position. Information! You can connect or disconnect VCDI unit from programmer any time you want, without any harm.