Download Print this page

PSA LIFESAVER 6000WIRM Manual

Wireless interlink relay module

Advertisement

Quick Links

Wireless Interlink Relay Module
Model 6000WIRM
Wireless Interlink and Relay Module for
LIFESAVER range of smoke alarms and
ancillary products.
This product is AC mains powered with
rechargeable battery backup.
Part Number: LIF6000WIRM
1203-7201-00
1

Advertisement

loading

Summary of Contents for PSA LIFESAVER 6000WIRM

  • Page 1 Wireless Interlink Relay Module Model 6000WIRM Wireless Interlink and Relay Module for LIFESAVER range of smoke alarms and ancillary products. This product is AC mains powered with rechargeable battery backup. Part Number: LIF6000WIRM 1203-7201-00...
  • Page 2: Table Of Contents

    Contents 1. Product Features And Specifications ........................2 2. Operational Features .................................3 3. Installation Instructions..............................4 4. Activation and RF Interlink Network ........................12 5. Warranty ....................................15 1. Product Features And Specifications • Electrical rating: 240 V AC 50Hz with 2 X 3V rechargeable battery back up •...
  • Page 3: Operational Features

    2. Operational Features The Lifesaver 6000WIRM is a mains powered wireless interlink module that allows hard wired Lifesaver smoke alarms to be connected to a wireless network. The built-in relay can be activated when smoke alarms or devices are activated. The module is fitted with a rechargeable backup battery.
  • Page 4: Installation Instructions

    LED indication There are two LED indicators. Each of them has a unique function: This relay module has two LED indicators (Red and Green). The LEDs indicate the following: Green • ON – AC Power is Present • OFF – AC Power is not Present •...
  • Page 5 B. Mount base plate on proper location. Mark and drill two holes for wall or ceiling anchors. Expansion pipe Wall 4.0mm 2.4mm 22mm Figure 3...
  • Page 6 C. Wire the cables into the appropriate terminals. Then turn ON the battery switch. Battery switch Selector switch Relay Smoke/Heat/CO alarm Terminals are classed as hazardous circuits. Tighten terminal screws to 0.8 N.m max. Figure 4...
  • Page 7 D. After the cables are connected, re-install the module cover. See Figure 5 below. Figure 5...
  • Page 8 Only connect to the specified models of smoke or heat alarm. Do not connect to any other brand of alarm/auxilary device unless approved by PSA. • The earth terminal connection provided is for termination purposes only and is NOT electrically connected within the sealed alarm / base units.
  • Page 9 • This wireless module can only interconnect with compatible smoke alarms. Interconnection with other brands may cause damage, result in electric shock, fire risk and void warranty. • It is important that the alarm be wired correctly to ensure correct operation. Incorrect wiring to the Smoke Alarm will damage the unit and void the warranty.
  • Page 10 The wiring connecting the module with the external device is not supervised. Be sure to test the operation of all the devices controlling the module or controlled by the module. Devices controlled by the module can be tested by pushing the Link button on the relay and verifying that the controlled device responds in the desired manner.
  • Page 11 Connect all the wireless devices using only the Active & Neutral lines. Do not connect to the SW terminal. See Figure 7 below. Household Cabling Household Cabling Active Active Neutral Neutral Figure 7 To connect a hardwired device such as a heat alarm to a wireless network, install the wireless module onto the heat alarms.
  • Page 12: Activation And Rf Interlink Network

    4. Activation and RF Interlink Network 4.1 Setting Up(6000WIRM) an RF Interlink Network For easy first time setup, we recommend unpacking all the units together on a desk or counter. Regarding 6000WIRM relay module please refer to below steps table. User Input Detector Response Timeout...
  • Page 13 4.2 Adding A Device (6000WIRM) To An Existing RF Interlink Network At some point, you might want to add another unit to your existing RF interlink network. Follow the steps in the following table. User Input Detector Response Timeout Press the LINK button twice Unit will respond with two quick - All devices interconnected will Step 1...
  • Page 14 Red LED on each unit will power off indicating Standby Step 3 other wireless unit to close the Join Mode Mode. To re-join a network, please start Step 4 over with Section 4.2 If any issues occur, please call PSA Technical Support.
  • Page 15: Warranty

    2 years from the date of purchase, as reflected on the Authorised Reseller’s or Distributor’s invoice / receipt provided to you. PSA Products Pty Ltd will repair or replace the product (at the option of PSA Products) due to any manufacturing defect, at the cost of PSA Products Pty Ltd (excluding any labour costs relating to removal or re-installation of product, and transport costs).

This manual is also suitable for:

Lif6000wirm