1. Overview
VER:V1
NF-567 is antemperature Time Controller. This product uses microcomputer
control technology and microprocessor as the core to realize intelligent
control output of temperature and time. The operation is convenient and
simple. Users can set and control the work and stop of other equipment
according to their own use. It is suitable for temperature and time control of
breeding room, farm, incubator, cold and hot ventilator, electric heating
equipment, water pump, boiler, and various household appliances.
2. The working principle
The instrument automatically samples the environment temperature through
the temperature sensor and detects it. When the environment temperature is
the same as the starting temperature set by the temperature controller, the
control circuit of the temperature controller starts When the ambient
temperature and the temperature controller set the same stop temperature,
the temperature controller control circuit to stop running.
3. Product buttons description
Stop state
Heating mode
Cooling mode
Stop temperature
Setup / Calibration
Engineering plastics
4. Operating Instructions
4.1 The temperature setting range of thetemperature Time Controller
The temperature setting range of the temperature controller is -9°C to
99°C. The red digital tube in the middle displays the actual temperature
detected by the sensor in the current environment, and the left and right
digital tubes display the stop and start temperatures set by the user.
4.2 Stop /start temperature
SET
ADJ.
STOP
START
4.3 High temperature start (Refrigeration control)
SET
ADJ.
STOP
START
4.4 Low temperature start (heating control)
Working status
NF-567
Heating mode
Cooling mode
SET
ADJ.
STOP
START
Start temperature
4.5 Local calibration function
NF-567
5 hole output
SET
ADJ.
STOP
START
01
After 2 seconds of power-on display, the red in
the middle shows the actual temperature
sensed by the sensor, and the white on the left
and right show the stop temperature and start
temperature set by the user respectively.
When "stop temperature" < "start temperature", the
temperature controller is in the "high temperature
NF-567
start" state as shown in the figure. At this time, the
green light is on, and the socket is powered. It is
mainly used for cooling, such as turning on the air
conditioner, exhaust fan, etc.
When "stop temperature" > "start temperature",
the temperature controller is in the "low
temperature start" state as shown in the figure.
At this time, the red light is on, and the socket is
powered off. Mainly used for heating.
Press the SET key for more than 3 seconds to
enter the calibration menu, use the up and down
keys to calibrate between -5 and 5 degrees, and
select 0 without correction.