1. Overview

VER:V1
NF-567 is antemperature Time Controller. This product uses microcomputer
control technology and microprocessor as the core to realize intelligent
control output of temperature and time. The operation is convenient and
simple. Users can set and control the work and stop of other equipment
according to their own use. It is suitable for temperature and time control of
breeding room, farm, incubator, cold and hot ventilator, electric heating
equipment, water pump, boiler, and various household appliances.

2. The working principle

The instrument automatically samples the environment temperature through
the temperature sensor and detects it. When the environment temperature is
the same as the starting temperature set by the temperature controller, the
control circuit of the temperature controller starts When the ambient
temperature and the temperature controller set the same stop temperature,
the temperature controller control circuit to stop running.

3. Product buttons description

Stop state
Heating mode
Cooling mode
Stop temperature
Setup / Calibration
Engineering plastics

4. Operating Instructions

4.1 The temperature setting range of thetemperature Time Controller
The temperature setting range of the temperature controller is -9°C to
99°C. The red digital tube in the middle displays the actual temperature
detected by the sensor in the current environment, and the left and right
digital tubes display the stop and start temperatures set by the user.

4.2 Stop /start temperature

SET
ADJ.
STOP
START

4.3 High temperature start (Refrigeration control)

SET
ADJ.
STOP
START

4.4 Low temperature start (heating control)

Working status
NF-567
Heating mode
Cooling mode
SET
ADJ.
STOP
START
Start temperature

4.5 Local calibration function

NF-567
5 hole output
SET
ADJ.
STOP
START
01
After 2 seconds of power-on display, the red in
the middle shows the actual temperature
sensed by the sensor, and the white on the left
and right show the stop temperature and start
temperature set by the user respectively.
When "stop temperature" < "start temperature", the
temperature controller is in the "high temperature
NF-567
start" state as shown in the figure. At this time, the
green light is on, and the socket is powered. It is
mainly used for cooling, such as turning on the air
conditioner, exhaust fan, etc.
When "stop temperature" > "start temperature",
the temperature controller is in the "low
temperature start" state as shown in the figure.
At this time, the red light is on, and the socket is
powered off. Mainly used for heating.
Press the SET key for more than 3 seconds to
enter the calibration menu, use the up and down
keys to calibrate between -5 and 5 degrees, and
select 0 without correction.
02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NF-567 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NOYAFA NF-567

  • Page 1 VER:V1 4.1 The temperature setting range of thetemperature Time Controller NF-567 is antemperature Time Controller. This product uses microcomputer The temperature setting range of the temperature controller is -9°C to control technology and microprocessor as the core to realize intelligent 99°C.
  • Page 2 Product Name Temperature Time Controller the setting time range is between 0001 and 9999 minutes. Corresponding time on Product Model NF-567 5.1 Refrigeration control the left: 1~99 settings. Corresponding time on the right: 1~99 settings. The left Temperature Sensing probe NTC10K-100cm When "stop temperature"...
  • Page 3 印刷要求 彩色 NF-567说明书英文20230206-V1 3折页 2023.02.15 无 样品 315x148mm 128g铜版纸 变更记录...

Table of Contents