The mini GAC
2500 is shipped with preset calibrations suitable for most customer use. Customers who desire
®
to measure moisture in other grains, nuts, and products should check the DICKEY-john
a calibration is available for their desired commodity. Once a calibration file is found and downloaded, customers
can use the steps below to load the calibrations onto their mini GAC 2500.
H A R D W A R E C O N N E C T I O N
To load grain calibrations onto the mini GAC
Transfer tool is required is required.
USB Symbol
NOTE: mini GAC 2500
functions are
inoperable while
connected to the
PC Application Tool.
500XXXX Rev A
2500, a USB cable and the mini GAC 2500 Product Calibration
®
1. Connect the USB cable to an available USB computer
2. Remove the dust protector from the mini GAC
the bottom of the unit near the
cable to mini GAC
®
3. When properly
connected,
mini GAC 2500
display.
when it is plugged
in.
4.
If
the mini GAC 2500 unit is
Figure 1 USB Connections
Mini
GAC
®
2500
Unit
handle.
Connect the other end of the
2500 USB
Port.
the USB symbol will appear on the
The mini GAC 2500 will power on
off,
press the on/off button to power
Computer
®
(Windows
7
and
10)
USS A to B Cable
1
G r a i n C a l i b r a t i o n s
website to determine if
®
port.
2500 port located on
®
on.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DOCKEY-john mini GAC 2500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TSI Instruments DOCKEY-john mini GAC 2500

  • Page 1 m i n i G A C 2 5 0 0 G r a i n C a l i b r a t i o n s ® The mini GAC 2500 is shipped with preset calibrations suitable for most customer use. Customers who desire ®...
  • Page 2 m i n i G A C 2 5 0 0 G r a i n C a l i b r a t i o n s ® U S I N G T H E P R O D U C T C A L I B R A T I O N T R A N S F E R T O O L NOTE: Reference the 1.
  • Page 3 m i n i G A C 2 5 0 0 G r a i n C a l i b r a t i o n s ® NOTE: Uploading new grain 4. Once the correct product slot is selected, click the “UPLOAD New calibrations can only be done Calibration”...
  • Page 4 m i n i G A C 2 5 0 0 G r a i n C a l i b r a t i o n s ® T R O U B L E S H O O T I N G Issue Probable Cause Corrective Action...

Table of Contents