B-Tech IR-B03 User Manual

B-Tech IR-B03 User Manual

Short wave infrared dryer

Advertisement

Quick Links

IR-B03 / IR-B03-T
Short Wave Infrared Dryer
User Manual for Short Wave Infrared Paint Curing Equipment
– Translation of German Original Document –
B-TEC GmbH • Zunftweg 6-8 • D-31303 Burgdorf / Ehlershausen • Tel.: +49(0)5085-97100-0
Fax: +49(0)5085-97100-30 • Email: info@btecsystems.de • www.btecsystems.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IR-B03 and is the answer not in the manual?

Questions and answers

Summary of Contents for B-Tech IR-B03

  • Page 1 IR-B03 / IR-B03-T Short Wave Infrared Dryer User Manual for Short Wave Infrared Paint Curing Equipment – Translation of German Original Document – B-TEC GmbH • Zunftweg 6-8 • D-31303 Burgdorf / Ehlershausen • Tel.: +49(0)5085-97100-0 Fax: +49(0)5085-97100-30 • Email: info@btecsystems.de • www.btecsystems.de...
  • Page 2 Union harmonisation legislation. If you modify the device without our explicit agreement, this declaration will be invalidated. Type of equipment: Paint drying equipment Type designation: IR-B03 IR-B03-T Serial number: ______________________...
  • Page 3: Table Of Contents

    3.2. Wiring Diagrams ........................5 3.3. Spare Parts..........................6 Installation ............................7 Operating Instructions ........................8 5.1. Temperature Control (Only IR-B03-T) ..................9 5.2. Memory Function ........................9 5.3. Distance Control ........................9 5.4. Curing Times .......................... 10 Maintenance and Care ........................10 6.1.
  • Page 4: Important Information

    The manufacturer and / or supplier is not responsible for damages caused by ignoring the instructions in this operating manual. Warranty and liability conditions of the manu- facturers and / or supplier sales and delivery terms are not extended by the above notes. IR-B03 / IR-B03-T Page 1...
  • Page 5: Safety Requirements

    Do not use this dryer in wet areas such as bathrooms or swimming halls. Keep the working site dry.  Keep the working area clean and free of any obstructions, oil, waste article or other broken parts. IR-B03 / IR-B03-T Page 2...
  • Page 6: Use

    Don’t misuse the electric wire. It is not allowed to drag the device with the power wire or pull the power plug. Please keep the power wire away from the hot, oily or sharp or movable objects. Please replace the damaged cables and wires as soon as possible for avoidance of electric shocks. IR-B03 / IR-B03-T Page 3...
  • Page 7: Technical Description And Intended Use

    1 - 35 min Temperature 60°C - 70°C Dimension (W x H x L) 890 x 1560 x 1090 *Max. overall height with cassettes: 2400 mm Digital display Pneumatic-aided lifting Ultrasonic distance measurement Temperature control (Only IR-B03-T) IR-B03 / IR-B03-T Page 4...
  • Page 8: Wiring Diagrams

    3.2. Wiring Diagrams Control Control Board 2 Board 1 ultrasonic emitter Figure 3-1 – Wiring diagram IR-B03 Main Switch 220-240V Control Control Board 1 Board 2 temperature ultrasonic laser module sensor emitter Figure 3-2 – Wiring diagram IR-B03-T – Technical changes and errors reserved. All pictures similar –...
  • Page 9: Spare Parts

    10000179 18 Cover plate 10000164 Handle for arm, black 10000144 19 Side cover of emitter 10000165 Armbox compl. incl. cable IR-B03 10000182 20 Heat dissipating plate 10000167 Armbox compl. incl. cable IR-B03-T 10000183 21 Small reflector plate 10000168 Socket for armbox...
  • Page 10: Installation

    When moving the emitter group up and down, use one hand to hold the Cross arm ⑥ on the handhold and push the pneumatic handle with ball knob ⑤ with the other hand. – Technical changes and errors reserved. All pictures similar – IR-B03 / IR-B03-T Page 7...
  • Page 11: Operating Instructions

    9. Point the laser on the part to be dried and set the temperature control as described in section 5.1 (Only IR-B03-T). 10. Choose emitter cassette(s) (3/4/5). 11. Press Start/Stop-button (10).
  • Page 12: Temperature Control (Only Ir-B03-T)

    5.1. Temperature Control (Only IR-B03-T) 1. Press Start key (15) and the temperature display (14) shows the actual temperature of the car body. 2. If you want to check the defined target temperature, press the button (12) and the tempera- ture display (14) shows the pre-set target temperature.
  • Page 13: Curing Times

    For replacing an emitter tube, ask the repair service center or a technician to do so.  If an emitter tube does not start working, it may result from a loose socket/cable. Switch off the device and check the sockets. IR-B03 / IR-B03-T Page 10...
  • Page 14: Replacing Emitter Tube

    Use a piece of soft cloth or cotton to clean the reflector plate and the tube with alcohol. Cleaning must be done after the device is disconnected with the power and cooled down. Don’t start the device until the alcohol has evaporated, otherwise it may lead to ignition. Disconnect IR-B03 / IR-B03-T Page 11...
  • Page 15: Troubleshooting

    Above specifications, drawings or diagrams are descriptive and subject to revision. If there are any discrepancies or changes, actual products shall prevail without otherwise notification. IR-B03 / IR-B03-T Page 12...

This manual is also suitable for:

Ir-b03-t

Table of Contents