ROUTINE MAINTENANCE
Filter Maintenance: The TRS600 is equipped with a
100-mesh screen filter. Check periodically. A partially
clogged filter will slow the recovery rate. Check as follows:
• Use a 5/8" socket or wrench to loosen suction port
(Figure 1).
• Remove suction port filter (Figure 2).
• Clean filter or replace with new filter.
• Inspect O-ring. Re-lubricate with compressor oil or
equivalent.
• Place filter assembly back into suction port fitting.
• Hand tighten (1/8 turn) assembly back into TRS600 (do
not overtighten). Damage to O-ring may result.
WARRANTY
CPS Products, Inc. guarantees that all products are free of manufacturing and material defects to the
original owner for one year from the date of purchase. If the equipment should fail during the guarantee
period it will be repaired or replaced (at our option) at no charge. This guarantee does not apply to
equipment that has been altered, misused or solely in need of field service maintenance. All repaired
equipment will carry an independent 90 day warranty. This repair policy does not include equipment that
is determined to be beyond economical repair.