1.Foreword Thank you for choosing our Sourcetronic ST150 series compact frequency inverter. The diagrams contained in these operating instructions are used for convenience of explanation and may be slightly different from the product due to product upgrades. Please refer to the actual product.
4.Operation of keyboard introduction Figure 4-1: Operation panel display 4.1 Keyboard indicators Indicator light Name Running indicator light * ON: The inverter is working * OFF: The inverter stops Forward/reverse running light Status FWD/REV * ON: In forward status light * OFF: In reversal status Frequency indicator Current indicator...
7. Parameter list In ST150 series frequency inverters, some parameters are “manufacturer reserved”, and their parameter numbers are not listed in the function parameter table, which leads to the discontinuity of some parameter numbers in the table. For the parameters not introduced in the manual, please do not attempt to modify them to avoid causing errors.
Page 6
Units digit: Frequency source selection; Frequency superimposed ☆ F0.07 Tens digit: Arithmetic relationship of master selection and auxiliary for frequency source ☆ F0.08 Auxiliary offset frequency 0.00Hz~F0.19 (Maximum frequency) 0.00Hz Shut down memory 0:W/O memory of UP/DOWN; ☆ F0.09 selection 1:With memory of UP/DOWN Frequency command 0: Relative to running frequency;...
Page 7
this terminal signal becomes inactive again, the inverter reverts to the previous state of running before parking. When the signal is sent to the inverter, the inverter reports fault External fault normally Err.15, and performs troubleshooting according to fault protection open input action (For details, please refer to the function code F8.17).
Page 8
This mode is the most commonly used two-wire mode. The forward/reverse operation of motor is determined by two terminals DIx, DIy. The terminal function is set as follows: Terminals Set value Description Forward run (FWD) Reverse run (REV) Of which, DIx and DIy are the multi-function input terminals of DI1~DI10, the level is active. K1 K2 Run Command DIx Forward run FWD...
Page 9
☆ F1.15 F1.14 corresponding setting -100.0%~+100.0% 100.0% Units digit: AI1 below the minimum input setting selection; ☆ F1.25 AI input setting selection 0: Corresponding to the minimum input F1.13 1: 0.0% ☆ F1.30 DI filter time 0.000s~1.000s 0.010s ☆ F1.31 AI1 filter time 0.00s~10.00s 0.10s...
Page 10
☆ F2.07 DA1 output function selection 0~17 Analog Output DA output range is 0V~10V, or 0mA~20mA, with the corresponding scaling function relationship in the following table Setting Functions Description and scaling value Running frequency 0~max. output frequency Set frequency 0~max. output frequency Output current 0~2 times the motor rated current Output torque...
Page 11
7.7. F5 group Vector control parameter group Factory Code Parameter name Setting range Change setting ☆ F5.00 Proportion of speed loop G1 1 ~ 100 ☆ F5.01 Speed loop integral T1 0.01s ~ 10.00s 0.50s ☆ F5.02 Switching frequency 1 0.00 ~ F5.05 5.00Hz ☆...
Page 12
☆ F7.09 Deceleration time 2 0.0s ~ 6500.0s ☆ F7.10 Acceleration time 3 0.0s ~ 6500.0s Depends on ☆ F7.11 Deceleration time 3 0.0s ~ 6500.0s models ☆ F7.12 Acceleration time 4 0.0s ~ 6500.0s ☆ F7.13 Deceleration time 4 0.0s ~ 6500.0s Switching frequency point between 0.00Hz ~ F0.19 (Max.
Page 13
☆ F7.51 AI1 input voltage upper limit F7.50 ~ 10.00V 6.8V 7.10. F8 group Fault and protection parameter group Factory Code Parameter name Setting range Change setting ☆ F8.00 Overcurrent stall gain 0~100 ☆ F8.01 Lost speed stall protection current 100%~200% ☆...
Page 14
units digit) Thousands Reserved digit thousands Reserved digit When "free stop" is selected, the inverter displays Err. *, and directly stops. When "Stop at the selected mode" is selected, the inverter displays Arr. *, firstly stops at the selected mode and then displays Err.
Page 15
☆ E0.07 Pulse per meter 0.1 ~ 6553.5 100.0 ☆ E0.08 Set count value 1 ~ 65535 1000 ☆ E0.09 Specified count value 1 ~ 65535 1000 7.14. E1 group Multi-speed, sample PLC parameter Factory Code Parameter name Setting range Change setting ☆...
Page 16
7.15. E2 group PID function parameter group Factory Code Parameter name Setting range Change setting 0: E2.01 setting; 1: Analog AI1 reference ☆ E2.00 PID setting source 5: Communications reference; 6: Multi-stage command reference ☆ E2.01 PID keyboard reference 0.0% ~ 100.0% 50.0% 0: Analog A1 given;...
Page 17
7.17. y0 group Function code management Factory Code Parameter name Setting range Change setting 0: No operation; 1 :Restore default parameter values, not including motor parameters; 2: Clear history; ★ y0.00 Parameter initialization 3: Restore default parameter values, including motor parameters;...
8. Fault alarm and countermeasures ST150 can provide effective protection against a number of fault situations. In case of abnormal operation, if a protection function is invoked, the inverter will stop output, the fault relay contact (in factory configuration) of the inverter will engage, and the fault code will be displayed on the display panel of the inverter. Before consulting the service department, user can perform a self-check, analyze the fault cause and find out the solution according to the instructions of this chapter.
Page 19
4. Consult support for help. causing the interference. Figure: Installation dimension drawing of ST150 external keyboard: Outline dimension drawing of keyboard Dimension drawing of ST150 external keyboard installation compartment: Dimension drawing of keyboard compartment ST150 English Manual V4.2 19 / 19...