User Manual
Indol W100A+
Värmepumpsberedare

Advertisement

loading

Summary of Contents for Indol W100A+

  • Page 1 User Manual Indol W100A+ Värmepumpsberedare...
  • Page 3: Table Of Contents

    Content 1. Preface............... 04 2. Safety Instructions..........05 3. Unit Dimension (mm) ......... 09 4. Maintenance............11 5. Parameters............19 6. Display Operation Guide ........20 7. Failure List & Troubleshooting......30...
  • Page 4: Preface

    Preface In order to provide customers with high-quality, strong reliable and good versatile products, this heat pump is manufactured by strict design and manufacture standards. This manual includes all the necessary information about installation, debugging and maintenance. Please read the manual carefully before you start or maintain the unit.
  • Page 5: Safety Instructions

    Safety I nstruction s The manual provides many important security measures for you to use the air source heat pump water heater. To prevent the users and others from the unpredictable/unexpected hurt of this unit, and avoid damage on the unit or other property, please read the manual carefully before using the unit.
  • Page 6 Warning Installation Meaning The heat pump must be installed by qualified personals, to avoid improper installation which may lead to water leakage, Professional installer electrical shock or fire. is required. Please make sure that the unit and power connection have good earthing, otherwise may cause electrical shock.
  • Page 7 ATTENTION Meaning Installation The unit CANNOT be installed near the flammable gas.Once there is any leakage of the gas,fire may occur. Must be at least 10 meters away from combustible material Installation Place Make sure that the basement of the heat pump is strong enough, to avoid any decline or fall down of the unit Fix the unit.
  • Page 8 Meaning Usage The earth electrode of socket should have the perfect earth wiring and the rating current should be more than 16A. Keep the socket and plug dry to avoid leakage and check if they are connected well usually. The check ways are as follow: Put the plug into the socket and turn on the unit, then pull out the plug half an hour later and check if the plug is hot.
  • Page 9: Unit Dimension (Mm)

    Unit Dimension (mm) Packing list About the Box Heat Pump Water Heater × 1 Pressure Release valve × 1 Straight Coupling × 1 Pressure Release valve × 1 Pressure Release valve × 1...
  • Page 10 Dimensions Cold water inlet Hot water outlet Overheating protector Condensing water drainage pipe Hanger Display Electric heater Air inlet Unit:mm Model W100A+ Air outlet 1117 Φ Φ...
  • Page 11: Maintenance

    Maintenance WARNING : This appliance can be used by children aged from 8 years and above and persons with reduced physical,sensory or mental capabilities or lack of experience and knowledge if they have been given supervisionor instruction concerning use of the appliance in a safe way and understand the hazards involved.Children shall not play with the appliance.
  • Page 12 Water quality shall meet the following conditions. Total Hardness Dissolved Water Saturation Dissolved Chloride Solids heater CaCO3) index Co2 mg/L s mg/L (TDS) system mg/L or (Langelier) or ppm or ppm mg/L or +0.4to-1.0 2500* @65℃ *For TDS levels up to and including 800mg/liter the magnesium based anode is to be used.
  • Page 13 If any hot work is to be conducted on the refrigeration equipment or any associated parts appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area 6) No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a...
  • Page 14 Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used.
  • Page 15 shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak Cabling Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration.
  • Page 16 Purge again with inert gas; Open the circuit by cutting or brazing. The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be "flushed" with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally...
  • Page 17 refrigerant cylinders: All personal protective equipment is available and being used correctly;  The recovery process is supervised at all times by a competent person;  Recovery equipment and cylinders conform to the appropriate standards.  d) Pump down refrigerant system, if possible e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system f) Make sure that cylinder is situated on the scales before recovery takes...
  • Page 18 condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged.
  • Page 19: Parameters

    5. Parameters Model W100A+ 230V~/50Hz Power Supply IPX1 Moisture Resistance Electrical Shockproof Heating Capacity Range 0.25 Heating Power Input Range Heating Current Input Range Auxiliary E-heater Max. Power Input Max. Current Input R290 / 150g Refrigerant / Proper Input Φ560×1117 Unit Dimension(L/W/H) ℃...
  • Page 20: Display Operation Guide

    Display Operation Guide 6.1. Function of wire controller Mode area Main dispaly area Status area ① ② ③ ④ 1)Function of key Button Name Function Switch unit running modes or save setting Mode parameters. Move up or increase parameter values. Move down or decrease parameter Down values.
  • Page 21 2)Function of display Status Name What it means icon Shows that the unit is in Standard heating Standard heating mode. mode Eco heating mode Shows that the unit is in eco heating mode Intelligent heating Shows that the unit is in Intelligent heating mode mode High demand...
  • Page 22 6.2 Usage of wire controller 6.2.1 Turn ON/OFF the unit Press " " and hold for 0.5s in the standby interface of the wire controller to turn on the unit and at this time the main display area shows the water outlet temperature. Press "...
  • Page 23 Standard heating mode We also call standard heating mode. The heat pump system will start according to the actual temperature and target temperature. The electric heater will not start immediately. After R06 time, the controller will judge if it reaches target temperature. If not, the electric heater will start. Press the “...
  • Page 24 Intelligent heating mode The heat pump automatically switches to economy mode, standard mode and high demand mode according to different ambient temperatures. When ambient temp reaches T01>R10 , the heat pump will enter Eco heating mode. (electric heater can not start up ) When ambient temp reaches R09<T01≤R10, the heat pump will enter standard heating mode.
  • Page 25 6.2.3 Target temperature checking and setting In the standby or running interface, press ” ” or ” ” once to check the target temperature of the outlet water. Press ” ” or ” ” again to change the target temperature. After making the changes to the parameter, press ”...
  • Page 26 6.2.4 Electric heating mode When the unit is off, press the “ ” for 2 seconds to manually initiate the electric heating mode, all other modes’ icons are off, main screen displays “OFF” and tank’s upper temperature at 2 seconds intervals in turn. If the electric heater is turned on, the icon of “...
  • Page 27 6.2.5 Tank’s bottom temperature display When the unit is on, you can press the “ ” for 2 seconds, so the screen will display the tank’s bottom temperature for 10 second. Then it will restore displaying the tank’s upper temperature after 10 seconds of no further action or press the “...
  • Page 28 6.2.6 Ventilation function When the unit is off, you can press the “ ” for 5 seconds to enter ventilation function, and its icon starts flashing. You can press the “ ” for 5 seconds again to cancel the function, then its icon stops flashing. Example: Prpress the “...
  • Page 29 6.2.7 Keyboard locking Press ” ” and hold for 5 seconds once to lock the keyboard. Press ” ” and hold for 5 seconds again to unlock the keyboard. Example: Prpress the “ ” for 5 seconds. Lock icon...
  • Page 30: Failure List & Troubleshooting

    Failure List & Troubleshooting 7.1. Non-error tips 1)Why the compressor is not running when I start up the unit? Answer: When the unit is powered on after the last shut-down, the compressor will not run until 3 minutes later. This is the self-protection of the unit. 2)Why sometimes the outlet water temperature on the display increases slowly? Answer:Because the water temperature is different between the upper layer and bottom layer in the tank at the beginning.
  • Page 31 distinguishing features of the units. Normally, the heating time is 2~6 hours according to the inlet water temperature, water consumption and ambient temperature. 7.2. The normal failure and solutions For any malfunctions, please refer to the table below: Display Malfunction Description Corrective action Bottom water temp.