Table of Contents

Ordering Information ........................................................................... 2
General Description .............................................................................. 2
Circuit Description ............................................................................... 3
Application Information ....................................................................... 5
Installation ............................................................................................ 8
Technical Specifications ..................................................................... 12
Operation ............................................................................................ 12
Warranty ............................................................................................. 14
CAUTION
Install or remove modules from the shelf only when the power is off.
If you install a module in the shelf with the power on, the internal
circuitry may suffer damage and the product warranty will be void.
Remove and install circuit boards only in a static-safe environment
(use antistatic wrist straps, smocks, footwear, etc.).
Keep circuit boards in their antistatic bags when they are not in use.
Do not ship or store circuit boards near strong electrostatic, electromag-
netic, magnetic, or radioactive fields.
For more complete information on electrostatic discharge safety
precautions, refer to Bellcore
Printed in the U.S.A.
I
& O
NSTALLATION
46035-01-1297 <90-00071>
M
ODULE
46035-01
CONVERTER
MODULE
XMT
XMT
RCV
RCV
XMT
DATA
A11-46035-01 REV__
TM
Technical Reference # TR-NWT-000870.
M
PERATION
ANUAL

Advertisement

loading
Need help?

Need help?

Do you have a question about the 46035-01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dantel 46035-01

  • Page 1: Table Of Contents

    For more complete information on electrostatic discharge safety Issue date: precautions, refer to Bellcore Technical Reference # TR-NWT-000870. Copyright 1999 by Dantel, Inc. • Dantel is a registered trademark of Dantel, Inc. • ISO 9001 Registered Printed in the U.S.A.
  • Page 2: Ordering Information

    ORDERING INFORMATION NOTE: This section lists the different options available for this product. To order any of the avail- able options, contact Dantel Inside Sales through our toll-free number, 1-800-432-6835. OPTION NUMBER FEATURES A11-46035-01 Converter Module GENERAL DESCRIPTION he 46035 Converter Module provides a means of transmit-...
  • Page 3: Circuit Description

    LEDs. A Power Supply The power supply uses -21 to -56 VDC input power which supplies +5 VDC and ±12 VDC operating power for the module’s circuits and an on-board subassembly. 46035-01-1297 <90-00071>...
  • Page 4 CIRCUIT DESCRIPTION . 1 - F , 46035-01 UNCTIONAL CHEMATIC 46035-01-1297 <90-00071>...
  • Page 5: Application Information

    Module with a 49008 subassembly, the printer port of the MAP can also be interfaced to the E2A remote. This allows expanded display reporting. The 46035 is also used to interface two remote site equipment shelves to a central location. Refer to Fig. 5. 46035-01-1297 <90-00071>...
  • Page 6 DATA DATA DATA DATA A11-00000-00 REV__ A11-00000-00 REV__ MAT W/49009 46035-01 46009 46035-01 Multiple Alarm CONVERTER Transmitter MODULE RS-485 ONLY CURRENT LOOP CURRENT LOOP DATA DATA DATA DATA A11-00000-00 REV__ A11-00000-00 REV__ With 49009 With 49009 Subassembly Subassembly 46035-01-1297 <90-00071>...
  • Page 7 APPLICATION INFORMATION . 5 - A PPLICATION IAGRAM ULTIPLE HELVES 46035-01-1297 <90-00071>...
  • Page 8: Installation

    RS-232, RS-422 or RS-485 data communications interfacing, ♦ RS-232 bridging, or RS-422/485 bridging or terminated. ♦ Configuring the subassembly RTS for always ON or under input control. . 6 - S , 46035-01 WITCH AND TRAP OCATIONS DIP SWITCH OPEN STRAP...
  • Page 9 2. The “destination” is where that poll exits the 46035 on its way to the remote equipment. 3. “-00” is a Dantel communications subassembly with a -00 part number. 4. “-01” is a Dantel communications subassembly with a -01 part number.
  • Page 10 RCV test points. The signal level should be 0 to -40 dBm, depending on your application. There is no field adjust- ment for this circuit. 5. Checkout Checkout consists of monitoring the unit’s front panel LEDs to verify data is being transmitted and received. 46035-01-1297 <90-00071>...
  • Page 11 INSTALLATION . 7 - P , 46035-01 C ESIGNATIONS ONVERTER ODULE Subassembly (see table below) Subassembly (see table below) Subassembly (see table below) Subassembly (see table below) (CTS) *NOTE: *DCD(RTS) *RXD(TXD) w/TTL, RS-232/422 function is reversed. *RTS(DCD) *TXD(RXD) Subassembly (see table below)
  • Page 12: Technical Specifications

    The 46035 Converter Module has two front panel LED indica- tors. The green LED, labeled XMT, flashes when data is trans- mitted. The yellow LED, labeled RCV, flashes when data is received. DATA A11-46035-01 REV__ TECHNICAL SPECIFICATIONS DESCRIPTION VALUE Input Power...
  • Page 13 NOTES 46035-01-1297 <90-00071>...
  • Page 14: Warranty

    To ensure expedient processing of your order, provide a purchase order number and shipping and billing information when requesting an RMA number. Also, when the units are returned to Dantel, include a descrip- tion of the failure symptoms for each unit returned. Send defective equipment to: Dantel, Inc.