Do you have a question about the MCL3 and is the answer not in the manual?
Questions and answers
Summary of Contents for Wintex Agro MCL3
Page 1
The future is in the soil - and in professional soil samplers Instruction manual ▪ 0-120 or 0-200 cm ▪ For all soils ▪ Robust construction ▪ Fast and user-friendly ▪ Efficient and reliable Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted +45 97990800, contact@wintexagro.com, www.wintexagro.com...
Page 2
Careful penetration at the beginning will give the operator a feeling of whether or not the above procedure is necessary. Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted +45 97990800, contact@wintexagro.com, www.wintexagro.com...
1. STARTING THE WINTEX MCL3 1.1. Starting the soil sampler with a cold engine: Set the choke, then close it. Throttle lever at 30%. Turn the start switch clockwise. Release the start switch after start. Run the engine, and gradually reduce the choke until smooth running is ensured.
Maintenance as recommended in the Honda owner’s manual for GX390 engine. Annually Service: Change oil and return filter. The soil sampler is pre-filled with Equivis XV46 oil. Check and change suction strainer if necessary. Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted +45 97990800, contact@wintexagro.com, www.wintexagro.com...
Page 6
Increase the pressure by screwing the Allen screw clockwise. 6.3. Changing oil and return filter Remove the two drain plugs (one drain plug on each side). Empty the tank for oil. Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted +45 97990800, contact@wintexagro.com, www.wintexagro.com...
4,18,19 Defect pressure regulator in block Creep in mast, park cylinders Defect counter valve in block Feed cylinder falls unactuated Defect counter valve Uneven stroke, slow feed up Defect membrane Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted +45 97990800, contact@wintexagro.com, www.wintexagro.com...
Page 8
Consult your dealer. Before starting locating faults, check that the oil flow from the power source is correct, and that the pressure relief valve is set correctly. Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted +45 97990800, contact@wintexagro.com, www.wintexagro.com...
Page 9
3) Charge the accumulator with nitrogen or 3) The accumulator pressure is too low. replace it. 4) Check the power source, the hoses and the 4) The return pressure is too high. filter. Wintex Agro, Vilhelmsborgvej 8C, DK-7700 Thisted +45 97990800, contact@wintexagro.com, www.wintexagro.com...
Need help?
Do you have a question about the MCL3 and is the answer not in the manual?
Questions and answers