Do you have a question about the Sitescan D-10 and is the answer not in the manual?

Questions and answers

lenre
March 19, 2025

how do you save your a peak on the d10 machine

1 comments:
Mr. Anderson
March 19, 2025

To save a peak on the Sonatest Sitescan D-10 machine, press the button to enter freeze mode, which holds an echo for evaluation. Press the button again to enter peak mode, which holds and updates all echoes on the display during inspection. In this mode, an envelope or echo dynamic pattern is drawn on the screen, allowing the peak signal to be located. A box labeled "PEAK" will be highlighted below the graticule to indicate this mode is active.

This answer is automatically generated

Summary of Contents for Sonatest Sitescan D-10

  • Page 1 Sitescan D-10 & D-20 Sitescan D-10 & D-20 User’s Guide User’s Guide...
  • Page 4 Sonatest Limited. prior written permission of Sonatest Limited. Sonatest Limited...
  • Page 5: Table Of Contents

    Sitescan D-10 & D-20 User’s Guide ~ Contents Sitescan D-10 & D-20 User’s Guide ~ Contents Contents Contents How to Use How to Use This User’s Guide This User’s Guide ....................................1 1 Typog Typographi raphical Conven cal Conventions tions ..
  • Page 6 Sitescan D-10 & D-20 User’s Guide ~ Contents 4.4.6 Distance Amplitude Correction (DAC) Menu ..........28 MEMORY Menu ....................29 4.5.1 PANEL Memory Menu..................29 4.5.2  A-LOG Memory Menu..................30 4.5.3 REF Menu......................30 4.5.4 T-FN ........................31 4.5.5 T-LOG Menu Numeric Mode................31 4.5.6 T-LOG Menu Delete Mode ................32 UTIL Menu......................33...
  • Page 7 Sitescan D-10 & D-20 User’s Guide ~ Contents 6.5.3 To delete all Files and all Locations: ..............64 6.5.4 To print thickness logs ...................65 Battery ..........................66 Battery Cautions ....................66 Battery Charging....................68 7.2.1 Charging Caution ...................68 Interface Connections.....................70 USB........................70 Composite Video ....................70 Features of the Sitescan D-10 &...
  • Page 8: How To Use How To Use This User's Guide This User's Guide

    Section 5: Flaw Testing gives guidelines on performing flaw testing with examples of how to calibrate the Sitescan D-10 & D-20 and how to set up the unit for DAC and TCG and how to use the A-Scan storage facilities.
  • Page 9: Disclaimers And Notices

    Competent training of the instrument operator. • This user’s guide provides instruction in the basic operation of the Sitescan D-10 & D-20 flaw detector. In addition to the methods included, many other factors can affect the use of this flaw detector. Specific information regarding these factors is beyond the scope of this manual.
  • Page 10: Testing Limitatio Testin G Limitations

    Sitescan D-10 & D-20 User’s Guide ~ Disclaimers and Notices More specific information about operator training, qualification, certification and test specifications can be obtained from technical societies, industry groups and government agencies. 2.4 Testing Limitations In ultrasonic testing, information is obtained only from within the confines of the sound beam as it propagates into the test material.
  • Page 11: Effects Of Temperature On Calibration

    Sitescan D-10 & D-20 User’s Guide ~ Disclaimers and Notices response. For these reasons, calibration should be performed on test blocks made of the same material as the test piece with artificial discontinuities within the range of size and depth in the material to be detected. The user is again cautioned to refer to reference books which are beyond the scope of this manual.
  • Page 12: Disclaimer Of Liability

    Sonatest Limited in connection with the use, features and qualifications of the Sitescan D-10 & D-20 are based on tests believed to be reliable, but the accuracy or completeness thereof is not guaranteed. Before using the product you should determine its suitability for your intended use based on your knowledge of ultrasonic testing and the characteristics of materials.
  • Page 13: Quick Start

    Sitescan D-10 & D-20 User’s Guide ~Quick Start 3 Quick Start 3.1 Front Panel The main control on the front of the unit is the scroll-wheel that is used to navigate through the menus and to adjust parameters this, along with the  key in the middle of the wheel...
  • Page 14 Sitescan D-10 & D-20 User’s Guide ~ Quick Start These buttons move the highlighted cursor along the top of the screen left and right to the sub menu to be selected, they are also used to make large increment changes to a selected parameter. These are momentary buttons  with no repeat.
  • Page 15 Sitescan D-10 & D-20 User’s Guide ~Quick Start Pressing the key again invokes the Hold mode that captures the current A- Scan in white allowing a comparison to be made with the live A-Scan that is shown in green. When this mode is selected a box is highlighted showing  as shown below:...
  • Page 16 Sitescan D-10 & D-20 User’s Guide ~ Quick Start The full screen button is used to toggle between showing the A-Scan on the full display and showing it with the menus and parameter boxes as shown below: Full display is useful for maximising the size of the A-Scan while performing inspections.
  • Page 17 Sitescan D-10 & D-20 User’s Guide ~Quick Start This button selects the help menu which overlays the display. The help menu explains how the Sitescan D-10 & D-20 operate with a choice of three options:  button : Basic operation rpbo  button...
  • Page 18 Sitescan D-10 & D-20 User’s Guide ~ Quick Start Page 11...
  • Page 19: Flaw Detection

    Sitescan D-10 & D-20 User’s Guide ~Quick Start 3.2 Flaw Detection Perform the following steps to establish a basic flaw detection mode for the Sitescan D-10 & D-20. Units shown are in inches. For inch units, select  from the  menu and...
  • Page 20 Sitescan D-10 & D-20 User’s Guide ~ Quick Start The Sitescan D-10 or D-20 is now configured for basic flaw detection. Using an appropriate calibration block, adjust the  parameter to establish the correct sensitivity. Adjust GAIN other parameters as necessary to optimize the calibration. For more in-depth features of the Sitescan D-10 &...