Installation Guide/Owner's Manual
1.0
Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.0
Owner/User Responsibilities . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.0
Safety Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
4.0
Input Electrical Specification. . . . . . . . . . . . . . . . . . . . . . . . . . 3
5.0
Standards and Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
6.0
Dimming Control Characteristics . . . . . . . . . . . . . . . . . . . . . . 3
7.0
Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
8.0
Cabinet and Module Installation . . . . . . . . . . . . . . . . . . . . . 4-8
9.0
Output Cabling to Fixtures . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
10.0
LED Load Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
11.0
Wiring Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
12.0
Compatible 0-10V Dimmers & Controls . . . . . . . . . . . . . . . .11
13.0
14.0
Inverter Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
15.0
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-13
16.0
User Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Kirlin Lighting | 3401 E. Jefferson Ave., Detroit, MI 48207-4232, USA | P: 313.259.6400 | www.kirlinlighting.com
Symphony
Symphony 0-10V System
Technical Support: 313-259-6400, Press 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 0-10V System and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Symphony 0-10V System

  • Page 1: Table Of Contents

    REMOTE DRIVER SYSTEM Installation Guide/Owner’s Manual Symphony 0-10V System Technical Support: 313-259-6400, Press 5 Scope ..........2 Owner/User Responsibilities .
  • Page 2: Remote Driver System

    INSTALLATION GUIDE/OWNER’S MANUAL SCOPE The KIRLIN Symphony 0-10V System is intended for installation and use in areas with large spaces and where servicing lights is difficult. The system includes a Symphony 0-10V Remote Driver Cabinet, Symphony 0-10V Remote Driver Module, and Symphony Luminaire (sold separately) that work in harmony to provide a quality lighting experience.
  • Page 3: Input Electrical Specification

    IES/EN 60929 annex E 0-10V NOTE: From 0.6V to 10V drivers comply with IEC/ EN 60929 annex E. Below 0.6V Symphony 0-10V Remote Driver Module comply with ABL 0-10V Design Spec v1.2 enabling standby mode. ANSI 62.41 1991 category B1: 2.5kV DM, 2.5kV CB @ Surge protection 30 Ohm 0-10V input 0.5kv DM, 1kV CM surge...
  • Page 4: Environmental Conditions

    Symphony REMOTE DRIVER SYSTEM INSTALLATION GUIDE/OWNER’S MANUAL ENVIRONMENTAL CONDITIONS Cabinet is intended for use in ambient temperature of 25°C max. Module operating ambient temperature (Ta) range -20°C to +50°C Acoustic noise - steady state < 24dBa (Class A) All components Dry location only CABINET &...
  • Page 5 Symphony REMOTE DRIVER SYSTEM INSTALLATION GUIDE/OWNER’S MANUAL CABINET & MODULE INSTALLATION (continued) Mechanical detail 18.13" 24.13" 21.00" 4x MOUNTING 15.00" 4X 1/2" - 3/4" TRADE SIZE 2X 3/4" - 1" TRADE SIZE KNOCKOUT EACH SIDE KNOCKOUTS EACH SIDE .13" 2X 1" - 1 1/4" TRADE SIZE...
  • Page 6 Symphony REMOTE DRIVER SYSTEM INSTALLATION GUIDE/OWNER’S MANUAL CABINET & MODULE INSTALLATION (continued) Mounting cabinet 1. Loosen the 4 screws that mount the cover panel; lift cover to align key hole slots, remove and set aside. 2. Place the cabinet in the desired location and mount using the 4 designated locations.
  • Page 7 Symphony REMOTE DRIVER SYSTEM INSTALLATION GUIDE/OWNER’S MANUAL CABINET & MODULE INSTALLATION (continued) Install modules 1. Each module is mounted in the cabinet via two threaded studs. Remove the keps-nuts installed on each stud, insert module, and replace both keps-nuts. 2. Repeat for each module to be installed.
  • Page 8 Symphony REMOTE DRIVER SYSTEM INSTALLATION GUIDE/OWNER’S MANUAL CABINET & MODULE INSTALLATION (continued) Input connections NOTE: Each cabinet ships with a jumper wire kit to allow fast & easy installation. The kit allows installer to customize dimming & switching zones by daisy chaining modules as needed.
  • Page 9: Output Cabling To Fixtures

    Symphony REMOTE DRIVER SYSTEM INSTALLATION GUIDE/OWNER’S MANUAL OUTPUT CABLING TO FIXTURES Output cabling must be #16 AWG (minimum) twisted pair shielded wire to minimize cross talk between channels and minimize Electromagnetic Interference (EMI). Total cable length must not exceed 250’ . See section 13 for cable suggestions.
  • Page 10: Wiring Example

    BLUE (-) RED (+) DO NOT CONNECT LED luminaries to energized driver For Symphony Installations, use of Symphony 0-10V Driver Modules are REQUIRED or Kirlin warranty is null and void. Requires 16 AWG twisted pair shielded wire from driver module to luminaire(s). See owner’s manual for...
  • Page 11: Compatible 0-10V Dimmers & Controls

    Symphony REMOTE DRIVER SYSTEM INSTALLATION GUIDE/OWNER’S MANUAL 12.0 COMPATIBLE 0-10V DIMMERS & CONTROLS COMPATIBLE 0-10V DIMMERS and SWITCHES Dimmer Manufacturer Type Dimming Curve Busch-Jaeger 2112U-101 Logarithmic Jung 240-10 Logarithmic Leviton Lighting Controls IllumaTech - IP710-DLZ / IP710-LFZ Logarithmic Lightolier Controls...
  • Page 12: Inverter Connections

    Symphony REMOTE DRIVER SYSTEM INSTALLATION GUIDE/OWNER’S MANUAL 14.0 INVERTER CONNECTIONS EMI-03120 The EMI-03120 will power up to 3 DVR modules during a power failure. Please see the installation manual supplied with the EMI-03120 for its specific wiring diagrams. EMI-21220 The EMI-21220 will power up to 8 DVR modules during a power failure. Please see the installation manual supplied with the EMI-21220 for its specific wiring diagrams.
  • Page 13 Symphony REMOTE DRIVER SYSTEM INSTALLATION GUIDE/OWNER’S MANUAL 15.0 TROUBLESHOOTING (continued) Fixtures Do Not Dim (Full Output Only) 1. Verify the installed 0-10V dimmer is approved for use in section 12.0 of the owner’s manual. Note: Some dimmers may cause reduced stability at the lowest dim level setting; this is normal and maybe resolved by increasing the lowest dim level setting if your selected dimmer allows.
  • Page 14: User Notes

    Symphony REMOTE DRIVER SYSTEM INSTALLATION GUIDE / OWNER’S MANUAL 16.0 USER NOTES Kirlin Lighting | 3401 E. Jefferson Ave., Detroit, MI 48207-4232, USA | P: 313.259.6400 | www.kirlinlighting.com...