Advertisement

Quick Links

BUKU PETUNJUK PEMAKAIAN
ULTRA ISOLATOR 500
ULTRA ISOLATOR 750
ULTRA ISOLATOR 1000
ULTRA ISOLATOR 1500
ULTRA ISOLATOR 2000
ULTRA ISOLATOR 2500
ICA
Rev.01
481-1710010-110
481-000-417

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ULTRA ISOLATOR 500 and is the answer not in the manual?

Questions and answers

Summary of Contents for ICA ULTRA ISOLATOR 500

  • Page 1 BUKU PETUNJUK PEMAKAIAN ULTRA ISOLATOR 500 ULTRA ISOLATOR 750 ULTRA ISOLATOR 1000 ULTRA ISOLATOR 1500 ULTRA ISOLATOR 2000 ULTRA ISOLATOR 2500 Rev.01 481-1710010-110 481-000-417...
  • Page 2 I. CATATAN KESELAMATAN I.1. Keselamatan Listrik Jangan bekerja sendiri dalam situasi berbahaya ● ● Tegangan tinggi melalui bahan konduktif dapat menyebabkan luka bakar ● Periksa agar kabel listrik, fiting, dan soket berada dalam kondisi baik ● Bila grounding tak dapat diverifikasi, putuskan hubungan peralatan listrik dengan keluaran listrik AC sebelum memasang atau menghubungkannya dengan peralatan lain.
  • Page 3 II. SPESIFIKASI TEKNIK ITEM UNIT SPESIFIKASI KET. Model UI500 UI750 UI1000 UI1500 UI2000 UI2500 Kapasitas 1000 1500 2000 2500 Tegangan Frekuensi 50 / 60 Proteksi 3.15 Sekring Tegangan ± 5% Frekuensi 50 / 60 Sistem Trafo Separasi Transformator Temperatur 0 ~ 40 Kerja Dimensi 304 x 190 x 160...
  • Page 4 III. TAMPAK PANEL ULTRA ISOLATOR POWER Ultra Isolator 1500, 2000 & 2500 Ultra Isolator 500, 750 & 1000 1. Saklar utama 2. Ventilasi 3. Input 4. Sekring input 5. Steker output IV. PEMILIHAN LOKASI Ultra Isolator dirancang untuk dipasang di lingkungan yang terlindung, terlarang dipasang pada kondisi berikut : 1.
  • Page 5: Service Centre

    SERVICE CENTRE Jln. Pinangsia Raya I No: 22BB Jakarta - 11120 Phone : (021) 6906020 (Hunting) Notes : For further information, please visit “www.icaups.co.id”. ---------------------------------------------------------------------------------- Catatan : Untuk informasi lebih lanjut, silakan kunjungi “www.icaups.co.id”.
  • Page 6 USER’S MANUAL ULTRA ISOLATOR 500 ULTRA ISOLATOR 750 ULTRA ISOLATOR 1000 ULTRA ISOLATOR 1500 ULTRA ISOLATOR 2000 ULTRA ISOLATOR 2500...
  • Page 7: Safety Notes

    I. SAFETY NOTES I.1. Electrical Safety ● Do not work alone under hazardous conditions. ● High current through conductive materials could cause severe burns. ● Check that the power cord(s), plug(s), and socket are in good condition. ● When grounding cannot be verified, disconnect the equipment from the utility power outlet before installing or connecting to other equipment.
  • Page 8: Technical Specification

    II. TECHNICAL SPECIFICATION ITEM UNIT SPECIFICATION REMARKS Model UI500 UI750 UI1000 UI1500 UI2000 UI2500 Capacity 1000 1500 2000 2500 Voltage Frequency 50 / 60 Protection 3.15 Fuse Voltage ± 5% Frequency 50 / 60 Transformator Separation Transformer System Operating 0 ~ 40 Temp.
  • Page 9: Panel View

    III. PANEL VIEW ULTRA ISOLATOR POWER Ultra Isolator 1500, 2000 & 2500 Ultra Isolator 500, 750 & 1000 1. Main Switch 2. Ventilation 3. Input 4. Input Fuse 5. Output IV. LOCATION SELECTION The Ultra Isolator is designed to be installed in a protected environment the following conditions should be prohibited : 1.
  • Page 10 SERVICE CENTRE Jln. Pinangsia Raya I No: 22BB Jakarta - 11120 Phone : (021) 6906020 (Hunting) Notes : For further information, please visit “www.icaups.co.id”. ---------------------------------------------------------------------------------- Catatan : Untuk informasi lebih lanjut, silakan kunjungi “www.icaups.co.id”.

Table of Contents