  • Page 1 HMI User manual WUXI XINJE ELECTRIC CO., LTD. Data No. HMC 01 20110520 3.0...
  • Page 2 All copyrights reserved by WUXI XINJE ELECTRIC CO., LTD. Any copying, transferring or any other usage is pro hibited. Otherwise Xinje will have the right to pursue legal responsibilities. All rights including patent and pemission of modules and designs are reserved.
  • Page 3: Table Of Contents

    2-3-1. MP330(-S)/MP325-A(-S) ..................24 2-3-2. MP360-L/MP760-T ....................25 2-3-3. Communication ....................... 27 Connection diagram of MP and other devices ..............28 3-1.Xinje FC/XC series PLC ....................28 3-2.FX/Q series of Mitsubishi ....................32 3-3.Siemens S7-200/300/400 series ..................35 3-4.Omron C series ....................... 37 3-5.KOYO S series ........................
  • Page 4 3-10.Facon FB series ......................47 3-11.Vigor VB series ......................50 3-12.Keyence KV series ......................52 3-13.Emerson EC20 series ....................55 3-14.OPTO22 series ......................57 3-15.SAIA-Burgess PCD series .................... 59 3-16.Fuji SPB series ......................64 3-17.Bosch Rexroth IndraControl L40 series ................ 66 3-18.OEMax NX7 series .......................
  • Page 5: Preface

    Preface Thank you for buying MP series HMI, this manual should be read and understood before doing relative operation.  Purpose This manual will guide readers in the correct operating and maintaining MP series HMI. Also, this manual refers to the application situations, operations, transportation, storage, set up, installation, maintaining and so on.
  • Page 6: Safety Caution

    Please cut off all the power when installing or disassembling the products, or it may cause error action and malfunction.  Please use MP series HMI in suitable environment conditions according to instructions, otherwise it may cause accident.  Please do not use the products where there is high frequency radiate, high magnetic...
  • Page 7: Mp Introduction

    1. MP introduction 1-1.Features MP series integrate the features of OP and TP series HMI. It has more choices and solutions for your machine. 1-1-1. Features ◆ Display: Size 3.7’’ and 7’’, blue LCD, 256 true color TFT LCD; Display area is touch screen;...
  • Page 8: Types

    1-1-3. Types Model Description 3.7’’, Kelly LCD, 192*64, 26 function buttons, touch screen, RS422 MP330 3.7’’, Kelly LCD, 192*64, 26 function buttons, touch screen, RS485 MP330-S 3.7’’, Kelly LCD, 192*64, 20 function buttons, touch screen, RS422 MP325-A 3.7’’, Kelly LCD, 192*64, 20 function buttons, touch screen, RS485 MP325-A-S 3.7’’, blue LCD, 192*64, 26 function buttons, touch screen MP360-L...
  • Page 9: Structure

    HMI specifications: Specification Item MP330(-S) MP325-A(-S) MP360-L MP760-T 256 colors TFT LCD type Kelly LCD Blue LCD 3.7 inch 7 inch LCD size 20000 hours, ambient temperature 25℃, 24 hours running Using life 192*64 480*234 Resolution Contrast Adjustable through potentiometer Unadjustable Language Chinese, English...
  • Page 10 Label Download/com port MODE : OP330 SN : 20060502118 DATE : 20060510 无锡市信捷科技电子有限公司 Power supply MP325-A (-S) RS485 and power terminal Download/com port Touch screen Function button...
  • Page 11 MP360-L Touch screen Function button Label Com port MODE : MP360L SN : 20080502118 DATE : 20080510 无锡市信捷科技电子有限公司 Download port 24V 0V Power terminal...
  • Page 12 MP760-T Touch screen Function button a a a a a a A L M STOP Label Com port Download port 24V 0V FG Power terminal...
  • Page 13: Buttons

    1-3-2. Buttons MP330 (-S)/MP325-A (-S)/MP360-L Key-press Function Whatever the mode of the display is in, it will return to original system screen once you press the key (the defaulted screen is No.1). Generally, set the original system screen to be main menu or most used screen. Turn the screen to the last page Turn the screen to the next page Press the key to modify the register value.
  • Page 14 MP760-T Function Running the program, LED indication light Stop running the program, LED indication light Whatever the mode of the display is in, it will return to original system screen once you press the key (the defaulted screen is No.1). Generally, set the original system screen to be main menu or most used screen.
  • Page 15: Download And Com Port

    1-3-3. Download and com port MP330 (-S)/MP325-A (-S) MP330 and MP325-A has one port. It can download and communicate with other devices. MP330/MP325-A MP330-S/MP325-A-S Function Function Pin1 Pin1 Pin2 Pin2 Pin3 Pin3 Pin4 Pin4 Pin5 Pin5 Pin6 Pin6 Pin7 Pin7 Pin8 Pin8 RDD-...
  • Page 16 The diagram of connecting with PC MP360-L/MP760-T Note: Connect pin 5 and 8 is forced download mode.
  • Page 17: Dimension

    1-4. Dimension 1-4-1. Product Dimensions MP330(-S)/MP360-L Unit: mm 56.5 MP325-A(-S) Unit: mm 162.2 35.5 172.0...
  • Page 18: Mounting Dimensions

    MP760-T Unit: mm 1-4-2. Mounting dimensions MP330(-S)/MP360-L Unit: mm...
  • Page 19 MP325-A(-S) Unit: mm 164.2 MP760-T Unit: mm...
  • Page 20: Software And Programming

    2-1-1. About the software The program of MP330, MP330-S, MP325-A, MP325-A-S is made through OP20 software. OP20 software: 2-1-2. Install and uninstall 1.Get the OP20 software from www.xinje.com 2.OS requirements: Windows98/2000/XP/Win7. 3.Installation steps (1) Double click “setup.exe” to enter the installation guide.
  • Page 21 (2) click next and “accept the agreement”. Click next to enter the serial number. Open “serial_no.txt” to know the serial number.
  • Page 22: Using Steps

    (3) Click next until finish the installation. Note: 1. If there is other version of OP20 in the PC, please choose different installation location. If the two versions are installed at the same location, the software cannot run normally. 2. Higher version of OP20 is compatible with lower version. But lower version isn’t compatible with higher version.
  • Page 23: Touchwin Software

    Bar map. To show the flow, pressure, level and so on. Insert bmp file. String. To show the contents in PLC register. Function button for touch operation (only for MP series panel) 2-2.TouchWin software 2-2-1. About the software The program of MP360-L, MP760-T should be edited in Touchwin software.
  • Page 24: Using Steps

    Run the software  build a new project  choose the panel type  choose the PLC port device  choose the download port device  edit the project  save the project  download the program into MP series products  communicate MP with other device 2-2-4. Tools and parts...
  • Page 25 Text input Input characters in the register Set data Set data and used in arithmetic Digital keyboard Digital input keyboard ASCII keyboard Character input keyboard User input One input button of keyboard Display the register value in bar picture Display the map according to the register value, Dynamic map support 16 maps, the register value is 0~15 Call window according to the value in the coil...
  • Page 26 Add jpg or bmp format pictures Move animation make the movement animation of object Rotate animation Switch the picture Material library The picture library Date Display the date Clock Display the time Buzzer Control the buzzer by the coil LCD light control Control the background light by the coil Scale Display the value in scale...
  • Page 27 Use with event, curve, alarm event, realize flip, Data moving button confirm and clear operation Alarm list Show the inverter alarm information in the list Display real time Display real time alarm information, when the event alarm is free, the event will be deleted automatically Display many alarm information and event Display history event happen time...
  • Page 28: Make The Program

    (2) Choose the MP model and PLC model: (3) Click OK to confirm the settings. 2. Please refer to OP software manual for making and downloading the program. The OP software manual download link: http://www.xinje.com/en/DownloadShow.asp?ID=232...
  • Page 29: Mp360-L/Mp760-T

    2-3-2. MP360-L/MP760-T The program of MP360-L and MP760-T are edited in TouchWin software. 1. Build a new project (1) Open the Touchwin software. (2) Click File/New or to build a new project. Select the correct MP type and com port device type com port device type (4) Set the com port device communication parameters according to PLC port device...
  • Page 30 (5) When download port (COM1) is not used as communication port, please select unuse download port. When use COM1 as com port, please select communication device. (6) Finish the building process. (7) Click to save the project in the PC. 2.
  • Page 31: Communication

    Please don’t cut the power when downloading. Please download again if the power is off. 2-3-3. Communication Connect MP with Xinje PLC through communication cable. Make sure the MP power supply is DC24V. Give the power for all the devices.
  • Page 32: Connection Diagram Of Mp And Other Devices

    3. Connection diagram of MP and other devices 3-1.Xinje FC/XC series PLC 1. Software settings Parameters Recommended Settings 9-Pin communication port Download Port PLC Port Communication port Communication Type RS232 Communication Distance Data Bit Stop Bit Verification Mode 9600 Baud Rate Modbus Number 2.
  • Page 33 (2) XC Series XC Address Operational Range Data Type Description 0~543 External input coil 0~543 External output coil 0~7999 Internal coil 0~1023 Internal coil 0~511 M8XXX Internal special coil 0~639 Timer 0~639 Counter 0~7999 Word//DWord Data register 0~639 Word//DWord Value of Timer 0~639 Word//DWord Value of Counter...
  • Page 34 (2) Connect to FC series CPU (RS485 port) Suitable Model: MP330-S Suitable Model: MP360-L、MP760-T (3) Connect to XC series CPU (RS232 port) Suitable Model: MP330、MP330-S、MP360-L、MP760-T (4) Connect to XC series CPU (RS485 port)
  • Page 35 Suitable Model: MP330-S Suitable Model: MP360-L、MP760-T (5) Connect to extend communication board XC-COM-BD( RS232 port) Suitable Model: MP330、MP330-S、MP360-L、MP760-T (6) Connect to extend communication board XC-COM-BD( RS485 port)
  • Page 36: Fx/Q Series Of Mitsubishi

    Suitable Model: MP360-L、MP760-T Suitable Model: MP330-S. 4. 8-pin round male port of FC/XC series PLC (Port1、Port2) 3-2. FX/Q series of Mitsubishi 1. Software settings Parameters Recommended Settings Download Port 9-Pin communication port PLC Port Programming Port/FX-422BD Communication Type RS422 Communication Distance Data Bit Stop Bit Verification Mode...
  • Page 37 XC Address Operational Range Data Type Description 0~177 External input coil 0~177 External output coil 0~8255 Internal coil 0~999 Stepping coil 0~255 Timer status 0~255 Counter 0~199 16-Bit Counter Word/DWord 200~255 32-Bit Counter DWord 0~8255 Word/DWord Data register 0~255 Word/DWord Current value 0~177 Word/DWord...
  • Page 38 Suitable model:MP360-L、MP760-T Suitable model:MP330-S (4) connect to Q series CPU (RS232 port) Suitable model:MP330、MP330-S、MP360-L、MP760-T (5) connect to Q series module QJ71C24 (RS232 port)
  • Page 39: Siemens S7-200/300/400 Series

    Suitable model:MP330、MP330-S、MP360-L、MP760-T (6) connect to Q series module QJ71C24 (RS422 port) Suitable model:MP330、MP360-L、MP760-T 3-3. Siemens S7-200/300/400 series 1. Software settings Parameters Recommended settings MP communication port RS485 port PLC communication port Terminal port or expanded communication port Communication type RS485 Communication distance 100m Data bit...
  • Page 40 0~31 Byte Internal auxiliary bytes registers 0~31 Word Internal auxiliary word registers 0~31 DWord Internal auxiliary double word registers 0~299 Byte Internal special auxiliary bytes registers 0~299 Word Internal special auxiliary word registers 0~299 DWord Internal special auxiliary double word registers 0~31 Byte Special auxiliary bytes registers...
  • Page 41: Omron C Series

    MP330/MP330-S:0 MP360-L/MP760-T:2 Notices: When MP series is in communication with Omron PLC, you need to set Omron PLC to ‘Monitor Run’ mode. Below is the operation method: Give power after setting the data in DM 6600 to H0201, then it will be ok.
  • Page 42 0~65535 Word/DWord Registers 0~65535 Word/DWord Registers 0~65535 Word/DWord Registers 0~65535 Word/DWord Registers 0~65535 Word/DWord Registers 0~65535 Word/DWord Words / double word data registers (2) SYSMAC CP/CJ/CS series PLC address Operational range Data type Description 0~9999 0~99999 0~9999 0~9999 0~9999 0~9999 Timer 0~9999 Counter...
  • Page 43: Koyo S Series

    3-5.KOYO S series 1. Software settings parameters Recommended settings MP communication port Communication port PLC communication port Terminal port or expanded communication port Communication type RS232 Communication distance Data bit Stop bit Verification mode 9600 Baud rate Modbus number MP360-L/MP760-T:1 2.
  • Page 44: Delta Dvp Series

    (2) connect to CPU unit 6 pins RJ-11 jack (RS232 communication serial port) Suitable model:MP330、MP330-S、MP360-L、MP760-T (3) RS422 communication type Suitable model:MP330、MP360-L、MP760-T 3-6.Delta DVP series 1. Software settings parameters Recommended settings MP communication port Communication port PLC communication port terminal port Communication type RS232 Communication distance...
  • Page 45 2. Address PLC address Operational range Data type description 0~377 External input coil 0~377 External output coil 0~1279 Internal auxiliary relay 0~1023 Stepping coil 0~255 Timer coil 0~255 Counter coil 0~1279 Word/D Word Data registers 0~255 Word/D Word Timer current value 0~255 Word/D Word Counter current value...
  • Page 46: Lg Master-K Series

    Suitable model:MP360-L、MP760-T 3-7.LG Master-K series 1. Software settings Parameters Recommended settings Master-K80/120S K80/120S (Cnet) MP communication port Communication port PLC communication port Terminal port Multifunctional port Communication type RS232 Communication distance Data bit Stop bit Verification mode None 38400 9600 Baud rate Modbus number 2.
  • Page 47 0~9999 Word/D Word Registers 0~9999 Word/D Word Registers 0~9999 Word/D Word Registers 3. Connection type (1) connect to CPU unit (RS232 communication serial port) Suitable model:MP330, MP330-S, MP360-L, MP760-T. (2) connect to CPU unit(use expanded communication module) Suitable model:MP330, MP330-S、MP360-L、MP760-T.
  • Page 48: Panasonic Fp Series

    3-8.Panasonic FP series 1. Software settings Parameters Recommended settings MP communication port Communication port PLC communication port Terminal port / communication port Communication type RS232 Communication distance Data bit Stop bit Verification mode 9600 Baud rate Modbus number Notice:The modbus number of FP PLC series is generally considered to ‘1’, but the modbus number of FP3 should be ‘0’...
  • Page 49 Notice:In the FP0 series, only the FP0-CXXCXX has the communication port ‘RS232’. (2) connect to CPU unit 9 pin D type male Suitable model:MP330、MP330-S、MP360-L、MP760-T (3) connect to CPU unit 8 pin D type male Suitable model:MP330、MP360-L、MP760-T (4) connect to CPU unit 8 pin D type male Suitable model:MP330、MP360-L、MP760-T...
  • Page 50: Schneider Micro/Neza/Twido Series

    3-9.Schneider Micro/Neza/Twido series 1. Software settings Parameters Recommended settings MP communication port Communication port PLC communication port Communication port Communication type RS485 Communication distance 100m Data bit Stop bit Verification mode Even 9600 Baud rate Modbus number Address PLC address Operational Data type Description...
  • Page 51: Facon Fb Series

    Suitable model:MP330-S 3-10.Facon FB series 1. Software settings parameters Recommended settings MP communication port Communication port PLC communication port Communication port/expanded communication port Communication type RS232 Communication distance Data bit Stop bit Verification mode Even 9600 Baud rate Modbus number Address PLC address Operational...
  • Page 52 3. connection type (1) connect to CPU unit (RS232 type) Suitable model:MP330、MP330-S、MP360-L、MP760-T (2) connect to CPU unit (RS485 type) Suitable model:MP330-S Suitable model:MP360-L、MP760-T...
  • Page 53 (3) connect to FB-DTBR/DTBR-E communication module (RS232) (15 pin D type male) Suitable model:MP330、MP330-S、MP360-L、MP760-T (4) connect to FB-DTBR/DTBR-E communication module (RS232)(9 pin D type male) Suitable model:MP330、MP330-S、MP360-L、MP760-T (5) connect to FB-DTBR/DTBR-E communication module (RS485) Suitable model:MP330-S Suitable model:MP360-L、MP760-T...
  • Page 54: Vigor Vb Series

    3-11.Vigor VB series 1. software settings Parameters Recommended settings MP communication port Communication port PLC communication port Communication port/expanded communication port Communication type RS232 Communication distance Data bit Stop bit Verification mode Even 19200 Baud rate Modbus number 2. Address PLC address Operational range Data type...
  • Page 55 (2) connect to CPU unit through RS232 communicational expanded card Suitable model:MP330、MP330-S、MP360-L、MP760-T (3) connect to CPU unit through RS485 communicational expanded card by RS422 Suitable model:MP330、MP360-L、MP760-T (4) connect to CPU unit through the RS485 communicational expanded card (RS485) Suitable model: MP330-S...
  • Page 56: Keyence Kv Series

    Suitable model:MP360-L、MP760-T 3-12.Keyence KV series 1. Software settings parameters Recommended settings MP communication port Communication port PLC communication port Terminal port Communication type RS232 Communication distance Data bit Stop bit Verification mode Even 9600 Baud rate Modbus number 2. Address PLC address Operational range Data type...
  • Page 57 (2) connect to Keyence KZ-300 series through serial port module KZ-L2 (Port1, RS232) Suitable model:MP330、MP330-S、MP360-L、MP760-T (3) connect to Keyence KZ-300 series through the serial port module KZ-L2 (Port2, RS232) Suitable model:MP330、MP330-S、MP360-L、MP760-T (4) Keyence KZ-300 series through the serial module KZ-L2 (Port2, RS422) Suitable model:MP330、MP360-L、MP760-T...
  • Page 58 (5) Keyence KZ-70 series through the serial port module KV-L20 (Port1, RS232) Suitable model:MP330、MP330-S、MP360-L、MP760-T (6) connect to Keyence KZ-700 series through the serial port module KV-L20 (Port2, RS232) Suitable model:MP330、MP330-S、MP360-L、MP760-T (7) connect to the serial port module KV-L20 (Port2, RS422) Suitable model:MP330、MP360-L、MP760-T...
  • Page 59: Emerson Ec20 Series

    3-13.Emerson EC20 series 1. software settings parameters Recommended settings MP communication port Communication port PLC communication port Terminal port Communication type RS232 Communication distance Data bit Stop bit Verification mode Even 19200 Baud rate Modbus number 2. Address PLC address Operational range Data type Description...
  • Page 60 (2) connect to COM1 communication port (RS232) Suitable model:MP330、MP330-S、MP360-L、MP760-T (3) connect to COM1 communication port (RS485) Suitable model: MP360-L、MP760-T Suitable model: MP330-S Notice: The communication port ‘COM1’ of the Emerson EC20 series PLC contains a R232 and a RS485 communication port, and only one of the ports can be chosen. At the same time, the unused port can not be connected with other cables to avoid the communicational interference.
  • Page 61: Opto22 Series

    3-14.OPTO22 series 1. software settings parameters Recommended settings MP communication port Communication port PLC communication port Terminal port Communication type RS232 Communication distance Data bit Stop bit Verification mode None 115200 Baud rate Modbus number 2. Address PLC address Operational range Data type Description 0~9999...
  • Page 62 Suitable model: MP330-S Suitable model:MP360-L、MP760-T (3) connect to CPU unit RS232 or RS485 port (RS232) Suitable model:MP330、MP330-S、MP360-L、MP760-T...
  • Page 63: Saia-Burgess Pcd Series

    3-15.SAIA-Burgess PCD series 1. software settings parameters Recommended settings MP communication port Communication port PLC communication port Terminal port Communication type RS232 Communication distance Data bit Stop bit Verification mode None 19200 Baud rate Modbus number Address PLC address Operational range Data type Description 0~4095...
  • Page 64 (2) connect to PGU (RS485) Suitable model: MP330-S Suitable model:MP330、MP330-S、MP360-L、MP760-T (3) connect to Socket A data port(PCD7.F120) Suitable model:MP330、MP330-S、MP360-L、MP760-T...
  • Page 65 (4) connect to the serial data port of Socket A(PCD7.F110) Suitable model: MP330-S Suitable model: MP360-L、MP760-T (5) connect to the serial data port of Socket A(PCD7.F110) Suitable model:MP330、MP360-L、MP760-T (6) connect to the serial data port of Socket B/B1 and B2(PCD2.F520/F530)...
  • Page 66 Suitable model:MP330、MP330-S、MP360-L、MP760-T (7) connect to the serial data port of Socket B/B1 and B2(PCD2.F520/F530) Suitable model: MP330-S Suitable model: MP360-L、MP760-T...
  • Page 67 (8) connect to the serial data port of Socket B/B1 and B2(PCD7.F772/F802) Suitable model: MP330-S Suitable model: MP360-L、MP760-T (9) connect to the serial data port of Socket B/B1 and B2(PCD2.520/F530) Suitable model:MP330、MP330-S、MP360-L、MP760-T (10) connect to the serial data port of Socket B/B1 and B2(PCD2.F520/F530) Suitable model:MP330、MP360-L、MP760-T...
  • Page 68: Fuji Spb Series

    (11) connect to the port of Socket B/B1 and B2(PCD2.F520/F530) Suitable model:MP330、MP330-S、MP360-L、MP760-T 3-16.Fuji SPB series 1. Software settings parameters Recommended settings MP communication port Communication port PLC communication port Terminal port Communication type RS232 Communication distance Data bit Stop bit Verification 19200 Baud rate...
  • Page 69 0~255 Word/D Word registers 32768~33023 Word/D Word registers 0~8191 Word/D Word registers 0~511 Word/D Word registers 0~255 Word/D Word registers 0~10000 Word/D Word registers 32768~33023 Word/D Word registers 3. Connection type (1) connect to NW0LA-RS2(RS232) Suitable model: MP360-L、MP760-T (2) connect to NW0LA-RS4 (RS485) Suitable model:...
  • Page 70: Bosch Rexroth Indracontrol L40 Series

    3-17.Bosch Rexroth IndraControl L40 series 1. Software settings parameters Recommended settings MP communication port Communication port PLC communication port Terminal port Communication type RS232 Communication distance Data bit Stop bit Verification mode None 38400 Baud rate Modbus number Address PLC address Operational range Data type Description...
  • Page 71: Oemax Nx7 Series

    3-18.OEMax NX7 series 1. Software settings parameters Recommended settings MP communication port Communication port PLC communication port Terminal port Communication type RS232 Communication distance Data bit Stop bit Verification mode None 9600 Baud rate Modbus number Address PLC address Operational range Data type Description R000.00~R31.15...
  • Page 72 Suitable model: MP360-L、MP760-T (2) connect to COM1communication port (RS485) Suitable model: MP360-L、MP760-T (3) connect to COM2 communication port (RS232) COM2 communication port Suitable model: MP360-L、MP760-T (4) COM2 communication port (RS485) Suitable model: MP360-L、MP760-T...
  • Page 73 Suitable model: MP360-L、MP760-T Notice: COM2 communication is RJ-45 standard 8 pin female. Pin 1 RS485+ and pin 3 RS485+ are connected inside together, and the pin 2 RS485- and pin 4 RS485- are also connected inside together.
  • Page 74 WUXI XINJE ELECTRIC CO., LTD. 4th Floor, Building 7th, No.100 Dicui Rd, Wuxi, China Tel: 86-0510-85134139 Fax: 86-0510-85111290 www.xinje.com Email: cheerfiona@gmail.com...

This manual is also suitable for:

Mp330Mp330-sMp325-aMp325-a-sMp360-lMp760-t

Table of Contents