Download Print this page
XPOtool 63908 User Manual

XPOtool 63908 User Manual

Pool pump with variable rotation speed

Advertisement

Quick Links

User's Manual
Pool Pump with Variable Rotation Speed
63908–63910
Illustration similar, may vary depending on model
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Illustrations, functional steps, and technical data may deviate insignificantly due to continuous further
developments.
Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.

Advertisement

loading

Summary of Contents for XPOtool 63908

  • Page 1 User’s Manual Pool Pump with Variable Rotation Speed 63908–63910 Illustration similar, may vary depending on model Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Illustrations, functional steps, and technical data may deviate insignificantly due to continuous further developments.
  • Page 2 To allow for a trouble-free complaint or return, it is important to contact our customer service team before returning your goods. Retourenabteilung WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler – Germany E-mail: service@wiltec.info Tel: +49 2403 55592–0 Fax: +49 2403 55592–15 https://www.XPOtool.com Item 63908–63910 Page 2 The Tool Experts 11 2022-1...
  • Page 3 • Whenever you use the pump, install the frequency converter according to the instructions. • Always and only operate the pump in accordance with the instructions. https://www.XPOtool.com Item 63908–63910 Page 3 The Tool Experts 11 2022-1...
  • Page 4 During operation, press this button to turn off. When there is a lack of water, On/off the information about the lack of water is deleted from the display screen. • In the off state, press this button to turn on. https://www.XPOtool.com Item 63908–63910 Page 4 The Tool Experts 11 2022-1...
  • Page 5 The rotation speed is saved; the Rotation speed setting 3000 unit is rpm. Any change is invalid and it is F08–F16 Reserved recommended not to change it! https://www.XPOtool.com Item 63908–63910 Page 5 The Tool Experts 11 2022-1...
  • Page 6 IPM module overcurrent pro- a short circuit between UVW phase error tection three phases of the 3- phase system. Fault in the current measure- Power pickup error Contact a specialist. ment circuit https://www.XPOtool.com Item 63908–63910 Page 6 The Tool Experts 11 2022-1...
  • Page 7 – Open valve and reduce pres- – Feedback pressure higher than set The motor does not work sure. pressure after power supply – Check whether water pump – Motor damaged or blocked works normally. https://www.XPOtool.com Item 63908–63910 Page 7 The Tool Experts 11 2022-1...
  • Page 8 – Eliminate interruption errors in up the water pump – Check if UVW wire is shorted the event of a short circuit. – Contact a specialist. https://www.XPOtool.com Item 63908–63910 Page 8 The Tool Experts 11 2022-1...
  • Page 9 WilTec Wildanger Technik GmbH Königsbenden 12 / 28 52249 Eschweiler Germany Important Note: Reproduction and any commercial use (of parts) of this operating manual, requires a written permission of WilTec Wildanger Technik GmbH. https://www.XPOtool.com Item 63908–63910 Page 9 The Tool Experts 11 2022-1...

This manual is also suitable for:

63910