SCHEU ALL-PRO Universal K75/SPC-K75 Owner's Manual

Forced air kerosene construction heaters

Advertisement

FORCED AIR KEROSENE CONSTRUCTION HEATERS
STOP
HEATER SPECIFICATIONS................................................................................................................ 2
WARNINGS .................................................................................................................................. 2
OPERATING PRECAUTIONS ............................................................................................................. 3
SAFETY PRECAUTIONS .................................................................................................................... 3
OPERATING INSTRUCTIONS ............................................................................................................ 4
MAINTENANCE, STORAGE AND SERVICE...................................................................................... 5
WIRING DIAGRAM .............................................................................................................................. 6
K75/SPC-K75, K125/SPC-K125, K175/SPC-K175 - EXPLODED VIEW ........................................... 7
K75/SPC-K75, K125/SPC-K125, K175/SPC-K175 - PARTS ............................................................. 8
WARRANTY ......................................................................................................................................... 9
SERVICE CENTERS .......................................................................................................................... 9
INSTRUCTIONS FOR ORDERING PARTS ........................................................................................ 9
WARRANTY REGISTRATION ........................................................................................................... 10
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
OWNERS MANUAL
K75/SPC-K75 K125/SPC-K125 K175/SPC-K175
Please do not return this product to the store.
If a part is damaged or missing, simply e-mail us at
php@allpro-heaters.com, or visit our website at
http://allpro-heaters.com, or call our Customer
Service Department at (888) 619-7060.
We will be happy to assist you!
You can register your heater on line at
http://allpro-heaters.com/warranty.

TABLE OF CONTENTS

© 2003 Scheu Products Company
Models
QUESTIONS?
MISSING / DAMAGED PARTS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALL-PRO Universal K75/SPC-K75 and is the answer not in the manual?

Questions and answers

Summary of Contents for SCHEU ALL-PRO Universal K75/SPC-K75

  • Page 1: Table Of Contents

    K75/SPC-K75, K125/SPC-K125, K175/SPC-K175 - EXPLODED VIEW ........... 7 K75/SPC-K75, K125/SPC-K125, K175/SPC-K175 - PARTS ............. 8 WARRANTY ............................9 SERVICE CENTERS .......................... 9 INSTRUCTIONS FOR ORDERING PARTS ..................9 WARRANTY REGISTRATION ......................10 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE © 2003 Scheu Products Company...
  • Page 2: Heater Specifications

    BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS. Scheu Products Company, Incorporated Mail: P.O. Box 250, Upland, CA 91785 Plant: 8855 Baker Ave., Rancho Cucamonga, CA 91730 Telephone: 800-325-7057 www.scheuco.com...
  • Page 3: Operating Precautions

    Models K75/SPC-K75 K125/SPC-K125 K175/SPC-K175 SAFETY PRECAUTIONS OPERATING PRECAUTIONS 1. Check the heater thoroughly for damage. DO NOT operate a This is a kerosene, direct-fired, forced air heater. It's intended damaged heater. use is primarily temporary heating of buildings under 2. DO NOT modify the heater or operate a heater which has construction, alteration or repair.
  • Page 4: Operating Instructions

    Models K75/SPC-K75 K125/SPC-K125 K175/SPC-K175 OPERATING INSTRUCTIONS UNPACKING 1. Remove all protective material which may have been PREPARING FOR OPERATION applied to the heater for shipment. 1. Check the heater for possible shipping damage. If any is 2. Remove heater from carton. found, immediately notify the factory.
  • Page 5: Maintenance, Storage And Service

    Models K75/SPC-K75 K125/SPC-K125 K175/SPC-K175 MAINTENANCE AND STORAGE 4.AIR PRESSURE SETTING. The air pressure has been WARNING. To prevent personal injury, unplug the heater properly set at the factory. If the air pressure is out of from the wall outlet before servicing. adjustment, it will most likely be caused by dirty air filters, a For maximum efficiency and trouble-free service, make the partially plugged nozzle, an air leak in the system or...
  • Page 6: Wiring Diagram

    Models K75/SPC-K75 K125/SPC-K125 K175/SPC-K175 WIRING DIAGRAM K75/SPC-K75 K125/SPC-K125 K175/SPC-K175 Page -6-...
  • Page 7: K75/Spc-K75, K125/Spc-K125, K175/Spc-K175 - Exploded View

    Models K75/SPC-K75 K125/SPC-K125 K175/SPC-K175 Page -7-...
  • Page 8: K75/Spc-K75, K125/Spc-K125, K175/Spc-K175 - Parts

    Models K75/SPC-K75 K125-FAT/SPC-K125 K175-FAT/SPC-K175 PARTS LIST Item Part No Part No Part No Description Item Part No Part No Part No Description K125 K175 K125 K175 6863 6863 6863 Oil Flame Control Assembly 1036 1036 1036 Power Cord 6865 6865 6865 Cad Cell Flame Sensor 2213...
  • Page 9: Warranty

    SERVICE CENTERS What is covered? This limited warranty covers all imperfections in workmanship and material. Scheu Products Company has over 1,000 service centers throughout North America. Call (888) 619-7060 or e-mail What is not covered? This limited warranty does not cover php@scheuco.com to request the service center nearest you.
  • Page 10 Page -10-...
  • Page 11: Warranty Registration

    Hand print only. Use black or blue ink pen to fill in this form. Cross or check inside the circle. Warranty Registration Your Information First Name Last name Mailing Address State City Postal code E-mail Address Annual house hold income before tax <$9,999 $10,000 to $19,999 >$50,000...
  • Page 12 SCHEU PRODUCTS COMPANY, INC ATTN: MARKETING DEPARTMENT 8855 BAKER AVENUE RANCHO CUCAMONGA, CA 91730 Visit our website for product information, technical support, customer service, and warranty registration at: WWW.ALLPRO-HEATERS.COM for All-Pro products or WWW.UNVERISAL-HEATERS.COM for Universal products. Page -12-...

Table of Contents