ENERGY BY NATURE Installation, Use and Maintenance Manual CONTENTS 1. Safety precautions 1.1 Meaning of icons 2. General information before installation 2.1 Usage requirements 2.2 Marking data 2.3 Recycling and disposal 3. Installation instruction (Technical Data) 3.1 Safety regulations 3.2 Delivery and Handling 4.
ENERGY BY NATURE 1. SAFETY PRECAUTIONS EDN recommends to carefully read the instructions specified in this Manual, since they provide important data about use, installation and safety. Improper product use and lack of compliance with any precautions and instructions contained in this Manual may cause serious damages to people, animals and objects.
Hemisphere) applying a tilt angle between 30° and 40°. A different orientation and tilt angle may cause heat rate variations. CAUTION: EDN shall not be liable in any way for any damages and injuries occurring to users, operators, third parties,...
Page 5
3.1 Safety regulations The non-compliance of safety regulations may cause serious damages and may have fatal consequences. EDN recommends that the installation operations are carried out only by qualified and experienced profes- sionals who shall also be required to issue the related installation compliance certification (see Regulations Table).
ENERGY BY NATURE 3. SAFETY REGULATIONS EDN recommends that the professionals dealing with CAUTION. EDN recommends installing the exchanger’s installation and routine and emergency RADIASOL in limited access areas. The maintenance should use the following Personal surfaces’ high temperatures and the Protective Equipment (PPE) and related accessories.
ENERGY BY NATURE 4. HYDRAULIC CONNECTION During the hydraulic connection, it’s EDN recommends using properly insula- necessary to cover the Exchanger to ted tubes and external fittings (low and avoid overheating. Discover RADIASOL return), to avoid heat dispersion and after the installation.
ENERGY BY NATURE 5. ELECTRICAL CONNECTION Users should arrange for a qualified technician to set up a two-pole socket with ground, to be positioned after DANGER. Connecting the exchanger with a key-operated disconnecting switch (or equivalent different voltages from those specified may cause the operator’s death or disconnection system).
The absence or the inefficiency of the check valve (compulsory for regulations) must cause damages to RADIASOL for decompression of the system. EDN recommends periodic controls of the non-return valve and its replacement every 2 years. REALIZZATO CON UN PRODOTTO AUTODESK VERSIONE PER STUDENTI...
Page 10
ENERGY BY NATURE REALIZZATO CON UN PRODOTTO AUTODESK VERSIONE PER STUDENTI Connection with accumulation CONNECTION WITH ACCUMULATION TO PRODUCE DOMESTIC HOT WATER for domestic hot water production SAFETY VALVE RADIASOL BOILER HYDRAULIC KIT -THREE WAY VALVE -MIXING VALVE NON RETURN VALVE HOT WATER EXPANSION VESSEL...
Page 11
ENERGY BY NATURE REALIZZATO CON UN PRODOTTO AUTODESK VERSIONE PER STUDENTI CONNECTION WITH INERTIAL ACCUMULATION, Connection with inertial storage, for heating and domestic FOR HEATING AND TO PRODUCE DOMESTIC HOT WATER (FORCED CIRCULATION) hot water production (forced circulation) SAFETY VALVE AUXILIARY BOILER RADIASOL...
Page 12
ENERGY BY NATURE REALIZZATO CON UN PRODOTTO AUTODESK VERSIONE PER STUDENTI INERTIAL ACCUMULATION CONNECTION Connection with inertial storage for FOR RADIANT SYSTEMS radiant systems SAFETY VALVE AUXILIARY BOILER RADIASOL heat pump - boiler REALIZZATO CON UN PRODOTTO AUTODESK VERSIONE PER STUDENTI INERTIAL ACCUMULATION (storage water)
ENERGY BY NATURE 7. FRAMES INSTALLATION Pitched roof-legs kit S010F Distance of the frames: Kit contents 150 D 4 screws M8x20 + 4 crew plates 416 mm 1 screw for grounding system 4 legs 200 D 516 mm 250 D 729 mm 300 D 910 mm...
Page 14
ENERGY BY NATURE Pitched roof-subtile kit S020F Distances of the frame: Kit contents 150 D 4 screws M8x20 + 4 crew plate 416 mm 1 screw for grounding system 4 under slating frames 200 D 516 mm 250 D 729 mm 300 D 910 mm (All models)
Page 15
(all models) The frames can withstand a maximum wind speed of 108 km / h (see Eurocode standards). EDN does not guarantee the frame for upper wind speed, it need using other fixing systems. It is ‘required to fix the frame to the ground (to prevent slipping) using the right “L”...
Page 16
2 tubes 25x25x1200mm The frames can withstand a maximum wind speed of 108 km / h (see Eurocode standards). EDN does not guarantee the frame for upper wind speed, it need using other fixing systems. It is ‘required to fix the frame to the ground (to prevent slipping) using the right “L”...
- Check the cable wear and cable grip of the electrical resistance. The absence or the inefficiency of non-return valve (compulsory for regulations) must cause damages to RADIASOL for decompression of the system. EDN recommends periodic controls of the non-return valve and its replacement every 5 years.
Page 18
THIS CERTIFICATE SHALL BE VALID ONLY IF DULY FILLED IN AND SIGNED Delivery date Document No. EXCHANGER’S SERIAL NUMBER CLIENT’S DATA Name Technician’s stamp and signature Surname Address Signature To send to: EDN srl - Zona Ind. Via dei Facocchi, 6 - Santa Maria degli Angeli - 06081 Assisi (PG)
Page 20
ENERGY BY NATURE EDN s.r.l. ENERGY BY NATURE Zona Ind. Via dei Facocchi, 6 Ph. +39 075 8044354 - Fax +39 075 8042916 06081 S. Maria degli Angeli - Assisi (PG) www.ednenergia.it info@ednenergia.it P.Iva 02889760548...