Page 3
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 Copyright The subject matter of this document causes the disclosure of Winston Marriot Ltd confidential and/or proprietary information. It shall not be disclosed to any person other than responsible officers and employees of yours who are aware that the same is commercially confidential and who are bound to treat it as such.
Page 7
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 The PICO PC 4 LAN fanless firewall router security gateway appliance, featuring the quad- core Intel® Celeron® Processor J1900 with Intel® HD graphics. It can be used as a security gateway to act as a virtual private network and network firewalls.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 Small and slim fanless aluminum alloy chassis smaller than A4 paper, with excellent ventilation and heat dissipation. Compact, lightweight, stylish and durable. Just 5.3 inches by 4.9 inches by 1.6 inches. Support 2.5" 7mm SATA SSD/HDD.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 OPENING THE CASE There are 4 screws (2 screws on each sides) for holding the case cover. By unscrewing these screws, you can remove the case cover to add or remove SSD, memory etc.
Page 15
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 PONDESK PICO PC 4 LAN Firewall router equipped with low power Nano-ITX (12*12 cm) industrial motherboard with Onboard Baytrail series quad-core J1900 processor. The following figure shows the top interfaces of the motherboard. In the process of installation of the device must be careful for some part, if not properly installed, it will not work properly.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 PROCESSOR The system is equipped with onboard Intel® Celeron® Processor J1900 (2M Cache, 2.42 GHz) processor powered by the Intel® Bay Trail series chipset. Features Intel® HD graphics. (Detail specifications: https://ark.intel.com/products/78867) MEMORY There is one SO-DIMM slot, which supports up to 8GB of DDR3L SODIMM 204Pins 1.35V low...
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 STORAGE The system supports dual storage drives including 1 x mSATA SSD & 1 x 2.5" 7mm SATA SSD/HDD. 3.4.1 mSATA SSD Turn off the machine and remove the chassis cover.
Page 19
3.4.2 2.5” SATA SSD/HDD PICO PC also support 1 x 2.5” SATA SSD OR 2.5” SATA HDD (7mm) secondary storage. To add 2.5” SSD in the machine, first remove the case cover and locate the SSD/HDD holes. (please refer to page # 12 & 13) First attach SSD/HDD with the case cover by the 4 screws and then connect the SATA data &...
The system supports wireless or 3G/4G LTE networks. There is one mini PCIe slot for WiFi or 3G/4G LTE module. 3.5.1 Wi-Fi PICO PC comes with 802.11 b/g/n 2.4GHz half mini PCI-E wireless card. (Up to 150Mbps) WWW.PONDESK.COM 3.5.2 3G/4G LTE System support 3G/4G LTE networks.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 INTERFACES 3.6.1 DC-IN There are two 12V input power connectors in the motherboard, DC_IN1 is a standard DC jack port and DC_IN2 is DT-126RP-02P terminal block interface. 3.6.2 CRT & VGA There are two type of standard display output interfaces including one standard CRT (female DE-15 connector) display output &...
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 3.6.4 The system equipped with 4x Intel® I211AT gigabit Ethernet controller. 3.6.5 SYSTEM FAN 3-pin connectors (SYS_FAN) to connect the system fan. (the system is fanless) PINS SIGNAL TMDS Data2+...
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 3.6.8 BAT1 (CMOS) CMOS battery connector labeled as “BAT1” equipped with TOSHIBA CR2032 3V external CMOS cable battery, provides power to the CMOS memory. All configurations in the CMOS memory will be reset to factory defaults if battery is disconnected.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 BIOS (basic input/output system) is the software stored in a tiny memory chip on the motherboard used to perform hardware initialization during the booting process and to provide run-time services for OS and other programs. The system records the system hardware configuration, parameters and settings in CMOS chip can be accessed in BIOS settings.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 4.2.1 MAIN MENU WWW.PONDESK.COM The main menu contains the BIOS information, system language selection, system date & time setup and user access level selection. Use arrow keys to select the items and press <Enter> to accept or enter Sub-menu.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 4.2.2.1 CPU CONFIGURATION WWW.PONDESK.COM CPU configuration and information Socket 1 CPU Information: Shows the specifications of the processor installed in the machine. Active Processor Cores: Set to Enabled to use a processor's core. The options are All, l, 2 and 3.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 4.2.2.2 PPM CONFIGURATION WWW.PONDESK.COM Processor power management (PPM) is the feature that provide support and settings for processor performance states and CPU C state report etc. EIST: Enhanced Intel SpeedStep Technology switches both voltage and frequency in tandem between high and low levels in response to processor load.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 4.2.2.3 IDE CONFIGURATION WWW.PONDESK.COM IDE or SATA Configuration, when selected, the BIOS automatically detects the presence of the SATA Devices and displays the settings SATA Controllers: This option enables or disables the on board SATA controller. The options are Enabled and Disabled.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 4.2.2.4 RTC RESUME CONFIGURE WWW.PONDESK.COM RTC Resume: Real time clock resume configuration is the feature to enable or disable the computer to wake (resume) from standby. The options are Enabled and Disabled.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 4.2.2.5 OS INSTALL SELECTION WWW.PONDESK.COM This section is used to change the operating system selection which is installed in the drive. LPSS & SCC Device Mode: This is used to configure the various Low-speed pin connections.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 4.2.2.6 CSM CONFIGURATION WWW.PONDESK.COM CSM (Compatibility support module) configuration is used to set the compatibility Option. INT19 Trap Response: To determines how the BIOS will react to INT19 trap-ping by Option ROM.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 4.2.2.7 USB CONFIGURATION WWW.PONDESK.COM USB Devices: Shows the Connected USB deices. Legacy USB Support: This feature enables support for legacy USB devices like the keyboard, mouse, and USB drive. Disable option will keep USB devices available only for EFI applications.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 4.2.3 CHIPSET WWW.PONDESK.COM The Chipset section provide the settings of North Bridge for internal graphics parameters, memory information, LCD control and power management settings; and South Bridge for USB configuration and PCI Express configuration etc.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 4.2.3.1 NORTH BRIDGE WWW.PONDESK.COM Intel IGD (Integrated Graphics Device) configuration includes GOP configuration and graphics settings. GFX Boot: Is a feature to test and create graphical boot logos for GFX boot compliant boot.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 4.2.3.2 SOUTH BRIDGE WWW.PONDESK.COM South Bridge contains settings of USB and PCI Express. USB Configuration: USB (Universal Serial Bus) configuration and settings. PCI Express Configuration: PCI express settings and config.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 4.2.4 BOOT WWW.PONDESK.COM Boot section display the settings and configuration of the available bootable devices. Quiet Boot: This feature allows to select the screen display between POST messages or the OEM logo at bootup.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 4.2.5 SECURITY WWW.PONDESK.COM The Security section provide the password security options for administrator and individual users. Minimum length: Passwords must be at least 3 characters long. Maximum length: Passwords can be up to 20 characters long.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 4.2.6 SAVE & EXIT WWW.PONDESK.COM Save Changes and Exit: Exit from the BIOS Setup after saving the settings and changes in system configuration, and reboot the computer, Discard Changes and Exit: This option quit the BIOS Setup without making any changes to the system configuration, and reboot the computer.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 RMA (Return Merchandise Authorization) is the procedure for returning faulty hardware for repair or replacement. While we take our quality control seriously, and check each system before dispatch. We understand the importance of protecting your investment with us.
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 Product Registration Register your product to get helpful information, efficient support, warranty information and to claim warranty and RMA by just providing your product serial number and purchase information.
Page 45
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 AHCI Advanced configuration and power management allows the operating system to control most of the power of the computer and its devices. BIOS Basic input/output system is software stored on a tiny memory chip on the motherboard used to perform hardware initialization during the booting process and to provide run-time services for OS and other programs.
Page 46
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 Local Area Network interface or network of interrelated computers within a small area, usually in an enterprise or a building. A LAN typically consists of servers, workstations, and some communication links.
Page 48
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 This section helps you to efficiently troubleshoot your system to ensure an accurate diagnosis of the problem. The following troubleshooting instructions provides procedures for comprehensions, identifications, testing and resolving common issues and problems.
Page 49
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 1. Improper installation or non-compatible software/driver is a leading cause of this issue. Run the system in SAVE MODE and remove the installation of recently installed software/driver. Blue screen or crashed? 2.
Page 51
Intel® Celeron® J1900 4 LAN 3G/4G HD Fanless Firewall Router MNHO-043 SATA Array Configuration Utility Internet Protocol Serial ATA AHCI SDRAM Advanced Host Controller Integrated Development Synchronous dynamic RAM Interface Environment SFP+ BIOS Small form-factor Basic Input/Output System Network Interface Card pluggable –...