Daihan Scientific Ba Series User Manual

Daihan Scientific Ba Series User Manual

Multi-use digital balance
Table of Contents

Advertisement

Available languages

Available languages

DAIHAN-Sci.com or ALL for LAB.com Shopping Mall
Multi-use Digital Balance
.
Certifications by - - -
ISO 9001 Certified.
PL Insurance (Product Liability Insurance)
User Manual
(Version: 1.0.0)
written for
Ba210 / Ba310 / Ba610 / Ba2.1k / Ba3.1k / Ba6.1k models
"Ba310" Multi-use Digital Balance
Sales & Basic Customer Service:
By the Nearest Official Distributors
Man311 (11 Jul. 2018)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ba Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Daihan Scientific Ba Series

  • Page 1 DAIHAN-Sci.com or ALL for LAB.com Shopping Mall Multi-use Digital Balance Certifications by - - - ISO 9001 Certified. PL Insurance (Product Liability Insurance) User Manual (Version: 1.0.0) written for Ba210 / Ba310 / Ba610 / Ba2.1k / Ba3.1k / Ba6.1k models “Ba310”...
  • Page 2: Table Of Contents

    DAIHAN-Sci.com or ALL for LAB.com Shopping Mall CONTENTS Page 1. General Information 1.1 Attention before Use..................1.2 Product Overview ....................1.3 Product Components .................... 2. Installation Information 2.1 Product Installation ..................... 2.2 Product Specification ..................... 3. How to Use 3.1 Attention in Use .................. 3.2 The Name of Each Part ..................
  • Page 3: General Information

    DAIHAN-Sci.com or ALL for LAB.com Shopping Mall 1. General Information 1.1 Attention before Use Thank you for your purchase of Multi-use Digital Balance. This manual describes the performance of the purchased product, how to use the product, and precautions in handling. Please make sure to read this product manual carefully before use.
  • Page 4: Product Overview

    - Product components are included in the package box of the released product. Picture Name No. of components Ba Series 1 unit of the main body Ba210 / Ba310 / Ba610 / Ba2.1k / Ba3.1k / Ba6.1k 12V DC Adapter...
  • Page 5: Installation Information

    DAIHAN-Sci.com or ALL for LAB.com Shopping Mall 2. Installation Information 2.1 Product Installation 1. DO NOT lay the product on the floor or impose a shock on it. Otherwise, the product can get internal damage. 2. Install the product on the firm and flat floor and make sure to use it in a stable place. 3.
  • Page 6: Product Specification

    DAIHAN-Sci.com or ALL for LAB.com Shopping Mall 2. Installation Information 2.2 Product Specification Model “Ba210”, Max. “Ba310”, Max. “Ba610”, Max. Spec 210g 310g 610g Weighing Range. g 0.01~210 g 0.01~310 g 0.01~610 g Read-Out [d] / Reproducibility. g 0.01 g / 0.01 g Linearity.
  • Page 7: How To Use

    DAIHAN-Sci.com or ALL for LAB.com Shopping Mall 3. How to Use 3.1 Attention in Use Before use  Make sure to read this user manual fully and the manual of a laboratory before using this product. This product should be used only by permitted persons. Install the product on the firm and flat floor.
  • Page 8 To transport the product or store in the high humidity state, check the package condition before use. If the box or the wood box sinks in water, contact the Technical Support Team of DAIHAN Scientific Co., Ltd. DO NOT operate the product until an engineer checks it. Otherwise, an electric shock or a fire may occur.
  • Page 9 If abnormal noise or abnormal operation symptom is found in use, immediately power off the product, unplug, and contact the product supplier or the Technical Support Team of DAIHAN Scientific Co., Ltd. To move the product, unplug the product and be careful not to get the power cord and the product damaged.
  • Page 10 ※ All circuits, and electric & mechanical parts and components used for this product are technological assets of DAIHAN Scientific Co., Ltd. The product should be repaired only by the technician(s) in the Technical Support Team of DAIHAN Scientific Co., Ltd. or by the technician(s) approved through the education of DAIHAN Scientific Co., Ltd.
  • Page 11: The Name Of Each Part

    DAIHAN-Sci.com or ALL for LAB.com Shopping Mall 3. How to Use 3.2 The Name of Each Part  External <Table.3.2.1> The name and descrption of each part This key is used to improve precision in weighing mode. Once this key is pushed, precision is improved twice, and one more digit place appears on Display.
  • Page 12: Directions

    DAIHAN-Sci.com or ALL for LAB.com Shopping Mall This key is used to enter a container weight. This key is used to cancel a container weight. This key is used to save a set value. This key is used to print out. <Table 3.2.1>...
  • Page 13 DAIHAN-Sci.com or ALL for LAB.com Shopping Mall 3.3.3. Basic Operation 1) Weighing (1) General weighing – which is used when gram (g) unit is applied for general weighing. Push CONVERSION key repeatedly until g(gram) or ct) is displayed. Whenever PRECISION key is pushed, a precision value is changed. At double precision, an additional digit appears.
  • Page 14 DAIHAN-Sci.com or ALL for LAB.com Shopping Mall This key works in the same way as in General Weighing mode. When this key is pushed, a container weight value is set to ‘0’ and ‘tare’ is displayed. This key works in the same way as in General Weighing mode. The current percentage value is displayed with a graph.
  • Page 15 DAIHAN-Sci.com or ALL for LAB.com Shopping Mall This key works in the same way as in General Weighing mode. The position of the current weight is displayed with a graph in the same way as in General Weighing mode. (5) Setting a reference value of counting It is possible to select one of 10, 20, 30, 40, 50, 60, 70, 80, 90, and 100 as a reference quantity.
  • Page 16 DAIHAN-Sci.com or ALL for LAB.com Shopping Mall Push this key repeatedly until CHK is displayed. Whenever this key is pushed in the same way as in General Weighing mode, precision is changed. At double precision, an additional digit appears. If the current value is lower than a target value, the bar graph moves in between LOW and OK;...
  • Page 17 DAIHAN-Sci.com or ALL for LAB.com Shopping Mall When ZERO key is pushed while setting, the setting process is cancelled. EXIT message appears and the scale returns to Comparison Weighing mode. (8)Animal weighing This mode is used to weight a moving object or an animal. A weight value is not stable so that the average value calculated during a certain time appears.
  • Page 18: Product Maintenance

    DAIHAN-Sci.com or ALL for LAB.com Shopping Mall 4. Product Maintenance 4.1 Maintenance Multi-use Digital Balance was developed in consideration of various conditions that can occur in operation. Nevertheless, to use long the system with stable performance, follow each of the following: 1.
  • Page 19: Troubleshooting

    DAIHAN-Sci.com or ALL for LAB.com Shopping Mall 4. Product Maintenance 4.2 Troubleshooting Trouble Checkpoints & Treatments If there is no display Check if the scale is powered off. Check that power cable is connected well. Check that the supplied power has no problem. If a measured value continues to Check that there is no move of wind and air.
  • Page 20: Product Warranty

    3. If a failure of this product is caused by a user’s careless treatment 4. If a failure is caused by natural disasters (fire, salt damage, gas damage, water damage, and others). DAIHAN Scientific Co., Ltd 326, Sinpyeongseokhwa-ro, Wolsong-ri, Jijeong-myeon, Wonju-si, Gangwon Call Center: 080-008-3000 for Customer Service...
  • Page 23 LAB.com DAIHAN-Sci.com or Shopping Mall Multi-use Digital Balance Certifications by - - - I N N O B I Z ( 기 술 혁 신 형 중 소 기 업 ) 인 증 ! ISO 9001 Certified. PL Insurance. (제조물 배상책임보험) VENTUR E Compa ny( )인증! 벤...
  • Page 24 LAB.com DAIHAN-Sci.com or Shopping Mall 목 차 Page 1. 일반사항 1.1 사용 전 주의사항..................1.2 제품 소개 ....................1.3 제품 구성 .................... 2. 설치사항 2.1 제품 설치 ..................... 2.2 제품 규격 ..................... 3. 제품 사용법 3.1 사용 시 주의사항 .................. 3.2 각...
  • Page 25: 일반사항

    LAB.com DAIHAN-Sci.com or Shopping Mall 1. 일반사항 1.1 사용 전 주의사항 Multi-use Digital Balance를 구입해 주셔서 감사합니다. 본 설명서는 구입하신 제품의 성능 및 사용법 그리고 취급상의 주의사항에 대하여 기술하고 있습니다. 제품 사용 전에 반드시 주의 깊게 읽어 주시기 바랍니다. 사용자의 주의가 반드시 필요한 부분에는 아래와 같은 경고 표시가 있으니 각 경고 표 시와...
  • Page 26: 제품 소개

    1.3 제품 구성 - 구성 품목은 제품 출고 시 포장박스 내부에 같이 들어 있습니다. 구성품 사진 구성품명 구성 개수 Ba Series 본체 1 unit Ba210 / Ba310 / Ba610 / Ba2.1k / Ba3.1k / Ba6.1k 12V DC Adapter Operation Manual...
  • Page 27: 설치사항

    LAB.com DAIHAN-Sci.com or Shopping Mall 2. 설치사항 2.1 제품 설치 1. 제품을 눕히거나 충격을 가하지 마십시오. 내부에 손상이 올 수 있습니다. 2. 바닥이 단단하고 평평한 장소에 제품을 설치하고 반드시 안정된 장소에서 사용하여 주십시오. 3. 주변에 정전기나 불안정한 전원 공급이 발생할 수 있는 장소는 피하여 설치하십시오. 4.
  • Page 28: 제품 규격

    LAB.com DAIHAN-Sci.com or Shopping Mall 2. 설치사항 2.2 제품 규격 “Ba210”, Max. “Ba310”, Max. “Ba610”, Max. Model Spec 210g 310g 610g Weighing Range. g 0.01~210 g 0.01~310 g 0.01~610 g Read-Out [d] / Reproducibility. g 0.01 g / 0.01 g Linearity.
  • Page 29: 제품 사용법

    LAB.com DAIHAN-Sci.com or Shopping Mall 3. 제품 사용법 3.1 사용 시 주의사항  사용하기 전에 본 제품을 사용하시기 전에는 꼭 사용자 매뉴얼을 숙지하여 주시고 실험실의 매뉴얼을 숙지하여 인가된 사람 외에 사용을 금해주시기 바랍니다. 바닥이 단단하고 평평한 장소에 설치하십시오. 그렇지 않을 경우, 부주의에 의한...
  • Page 30 LAB.com DAIHAN-Sci.com or Shopping Mall 락카, 페인트 등 인화성 스프레이나 휘발성, 인화성 약품 및 그 유사품은 제품 가까이에서 사용하지 마십시오. 스위치의 불꽃 등으로 인하여 발화의 원인이 됩니다. 비 인가된 사람에 의해 제품을 분해하거나 변형시키지 마십시오. 심각한 전기적 문제를 야기시킬 수 있으며 ㈜대한과학의 보증서비스를 받을 수 없습니다.
  • Page 31 LAB.com DAIHAN-Sci.com or Shopping Mall 히터가 내장되어 있으므로 히터 동작 시 손을 델 경우 화상을 입을 수 있습니다. 수분측정기를 개폐할 경우에는 히터커버 손잡이를 이용하십시오. 수분측정기의 일부분이 매우 뜨거워지므로 화재의 원인이 될 수 있으니 히터커버 위에 아무것도 올려놓지 마십시오. 히터나 에어컨 근처에서 제품을 작동하지 마십시오. 햇빛이...
  • Page 32 LAB.com DAIHAN-Sci.com or Shopping Mall 주 전원 전압의 변동이 공칭전압 +/-10% 이하여야 합니다. 최대 상대 습도는 31℃에서 80% 와 40℃에서 50% 입니다. 제품을 운반하거나 습도가 높은 상태에서 저장 한 경우 사용하기 전에 포장 상태를 확인하시기 바랍니다. 상자 또는 나무 상자가 물에 잠기는 경우에는 ㈜대한과학의...
  • Page 33: 각 부의 명칭

    LAB.com DAIHAN-Sci.com or Shopping Mall 3. 제품 사용법 3.2 각 부의 명칭 외부  <Table.3.2.1> 각 부의 명칭 및 설명 계량모드에서 정밀도를 향상 할 때 사용합니다. 누르면 두 배로 정밀도가 향상되고 디스플레이에 한자리 더 표시됩니다 다시 누르면 원래 상태로 복귀 합니다 퍼센트...
  • Page 34: 사용법

    LAB.com DAIHAN-Sci.com or Shopping Mall 용기무게를 입력할 때 사용합니다 용기무게를 취소 할 때 사용합니다 설정 값을 저장 할 때 사용합니다 프린터 출력 시 사용합니다 <Table 3.2.1> 키 설명 "Ba210" 3. 제품 사용법 3.3 사용법 3.3.1. DISPLAY <Figure 3.3.1> LCD Display for Controller 12/21...
  • Page 35 LAB.com DAIHAN-Sci.com or Shopping Mall 3.3.3. 기본 동작 1) 계량하기 (1) 일반계량 - 그램(g)무게단위를 일반적인 계량할 때 사용합니다 CONVERSION 키를 반복 입력하여 g(gram)혹은 ct)이 표시되도록 합니다 PRECISION key 를 누를 때 마다 정밀도가 바뀝니다 두 배 높은 정밀도 일 때 보조눈금이...
  • Page 36 LAB.com DAIHAN-Sci.com or Shopping Mall 일반계량 할 때와 동일 하게 작동 합니다 현재 퍼센트 값을 그래프로 보여줍니다 (3) 퍼센트 기준 값 설정 하기 MENU key를 입력하면 ‘REF.Set’ message가 깜빡인 후 설정모드로 진입 합니다. ‘ Ld 100 ’이 표시 되면 100%에 해당 하는...
  • Page 37 LAB.com DAIHAN-Sci.com or Shopping Mall 일반 계량일 때와 동일 하게 현재 무게의 위치를 그래프로 보여 줍니다 (5) 부품계수 기준값 설정 하기 기준 수량을 10, 20, 30, 40, 50, 60, 70, 80, 90, 100 중에 선택하여 설정 할 수 있습니다 ENTER key를 입력 하면 ‘REF.Set’...
  • Page 38 LAB.com DAIHAN-Sci.com or Shopping Mall 일반 계량에서와 같이 누를 때 마다 정밀도가 바뀝니다 두 배 높은 정밀도일 때 보조 눈금이 나타납니다 목표 값보다 현재 값이 작을 때 막대 그래프가 LOW와 OK사이에서 움직입니다 목표 값보다 현재 값이 클 때는 OK와HI사이에서 움직입니다 ** 체크계량에서는...
  • Page 39 LAB.com DAIHAN-Sci.com or Shopping Mall (8)동물계량 움직이는 물체나 동물을 계량할 때 사용합니다. 계량 값이 안정되지 않기 때문에 일정시간 평균한 값을 나타내 줍니다 CONVERSION 키를 반복 입력 하여 ANI가 표시 되도록 합니다 MENU key를 누르면 AVrIng’ message가 나타나고 잠시 후부터 평균 계량이 시작 합니다 외부에...
  • Page 40: 제품 관리법

    LAB.com DAIHAN-Sci.com or Shopping Mall 4. 제품 관리법 4.1 유지 및 관리 Multi-use Digital Balance 는 작동 중 발생할 수 있는 다양한 상황들을 고려해 제작 되었습니다. 그러나 안정된 성능으로 장기간 동안 사용하시기 위해서 다음의 아래 사항들을 반드시 준수하여 주시기 바랍니다. 1.
  • Page 41: 이상 발생 시 처리

    LAB.com DAIHAN-Sci.com or Shopping Mall 4. 제품 관리법 4.2 이상 발생 시 처리 상태 확인 및 조치사항 화면 표시가 나타나지 않는 경우 저울의 전원이 꺼져 있는지 확인합니다. 전원 케이블이 제대로 연결되어 있는지 확인합니다. 공급되는 전력에 이상이 없는지 확인합니다. 측정값이 계속 변할 경우 바람과...
  • Page 42: 제품 보증

    LAB.com DAIHAN-Sci.com or Shopping Mall 5. 제품 보증 5.1 품질 보증 품 질 보 증 서 (CERTIFICATION)  이 보증서의 소정 항목에 기재되지 않은 사항이 없는지 확인하여 주십시오.  이 보증서의 기재 내용에 따라 보증하여 드립니다.  이 보증서는 대한민국 국내 고객용이며 아래 보증 내용을 참조 하십시오. ...
  • Page 43: 전국 대리점

    LAB.com DAIHAN-Sci.com or Shopping Mall 5. 제품 보증 5.2 전국 대리점 지역 AS 책임 담당자 주소 전화 팩스 (주)대한과학 종로 (대표 서강민) 서울특별시 종로구 종로 140 금천빌딩 203호 02-2274-0216 02-2276-0216 (주)대한올포랩 (대표 이재웅) 서울특별시 성북구 화랑로 186 수정빌딩 4층 02-968-1035 02-968-1039 (주)대한와이즈랩...

This manual is also suitable for:

Ba210Ba310Ba610Ba2.1kBa3.1kBa6.1k

Table of Contents