  • Page 1 MPAC-18 OPERATING AND SERVICE MANUAL Copyright 2004 7640 Pelham Road Computer Dynamics, Inc. Greenville, SC 29615 864-627-8800 Page 1 8/20/2004 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 2 Pentium™ , Pentium II™, Pentium III™ and Celeron™ are trademarks of Intel Corporation Phoenix BIOS™ is a trademark of Phoenix Technologies Ltd. Universal Serial Bus, Specification Copyright Compaq Computer Corporation, Intel Corporation, Microsoft Corporation, NEC Corporation. ® VESA is a registered trademark and VBE™ is a trademark of the Video Electronics Standards Association.
  • Page 3: Revision History

    5/16/03 R.T. Harrelson A-08 5/24/2004 Allen Gaulden Copyright March 2003, Computer Dynamics, Inc. REVISION HISTORY Preliminary Release Preliminary Release Preliminary Release Preliminary Release Preliminary Release Preliminary Release Preliminary Release 10Base2 Option Page 3 All Rights Reserved MPAC-18 Manual DESCRIPTION 8/20/2004...
  • Page 4: Table Of Contents

    Figure 3. Side Plan View...29 Figure 4. Top Plan View...29 Figure 5. Back Plan View...30 Figure 6. Installation Diagram...31 Figure 7. Pin configuration ...33 Figure 8. I/O Panel...35 Page 4 8/20/2004 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 5 Table 3 Parallel (LPT-1) Jack ...36 Table 4 Ethernet Jacks ...37 Table 5 Power Jack...37 Table 6 USB Jack ...37 Table 7 Serial Jack, RS232 & RS485 ...38 Page 5 8/20/2004 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 6: Introduction

    USB1&2, and the combined keyboard and mouse. The Ethernet I/O is designed to provide a dual 10Base2 interface to a network. Copyright March 2003, Computer Dynamics, Inc. Com A Com B Com C Com D Printer port or Parallel Page 6 All Rights Reserved MPAC-18 Manual...
  • Page 7 No warranties of merchantability or fitness for purpose shall apply. Page 7 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 8: Feature Summary

    Two, Ethernet 10Base2 One, DB9, See pinout Table 2 One, Side access Location Internal (Touch screen) Bottom access Bottom access Bottom access Bottom access Bottom access Bottom access Two, Internal, Factory option only Page 8 All Rights Reserved MPAC-18 Manual...
  • Page 9: Installation Guidelines

    Once the bracket is mounted, the computer is mounted to the bracket. Use the four provided allen screws, and combine with a washer and lock washer (not included). Two people are required to mount Copyright March 2003, Computer Dynamics, Inc. Page 9 All Rights Reserved MPAC-18 Manual...
  • Page 10 Brackets: See figures 3 and 4 for proper clearances for each bracket assembly. An access area of approximately 4 inches (10 cm) to the sides is required in the area of the allen screws that mount the computer to the bracket. Page 10 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 11: Power-Up And Software Installation

    You will need to use the T correct, press E NTER Copyright March 2003, Computer Dynamics, Inc. Caution NTER key to get to each number field. If Page 11 All Rights Reserved MPAC-18 Manual...
  • Page 12 17. At the end of the setup process, you will be asked to reboot the system. Press E Copyright March 2003, Computer Dynamics, Inc. Note Note NTER key, and type the password in the NTER NTER Page 12 All Rights Reserved MPAC-18 Manual key and type NTER...
  • Page 13 Computer names should be less than or equal to ten characters to run some software programs. Each computer on a network must have a unique name. Copyright March 2003, Computer Dynamics, Inc. Note Page 13 All Rights Reserved MPAC-18 Manual...
  • Page 14 To modify the TCP/IP properties, Go to the Protocols Tab, highlight TCP/IP protocol, and click Properties. Page 14 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 15 Obtain an IP address from a DHCP Server. Note The factory setting for the IP is 111.111.111.111 and for the Subnet is 255.0.0.0. If necessary, consult your network engineer to select appropriate addresses. Page 15 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 16 Windows Service Pack be reinstalled to update any files that were added or overwritten. When you have finished setting up the Network, click OK in the Network dialog box. Click Yes to reboot your system now. Copyright March 2003, Computer Dynamics, Inc. Note Page 16 All Rights Reserved MPAC-18 Manual...
  • Page 17 The network shares for the system have been left at their default administrative settings. To modify them, double click My Computer on the desktop, highlight C:, and view the drive's properties by clicking File, Properties. Select the Sharing tab. Page 17 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 18: Installing Application Software

    Copyright March 2003, Computer Dynamics, Inc. Windows OS CD Touch screen drivers Network drivers Service pack Note Warning Caution Page 18 All Rights Reserved MPAC-18 Manual...
  • Page 19: Touch Screen

    The system has network capability by way of one Ethernet interface, which consists of two pairs of RX/TX 10 Base 2. The copper interface uses the Trompeter ADBJ20-E1- Copyright March 2003, Computer Dynamics, Inc. Page 19 All Rights Reserved MPAC-18 Manual...
  • Page 20: Power Input

    A DB9 connector is located on the bottom access panel. This port is labeled accordingly. This temporary connection is intended to be used for such things as initial setup, downloading data, uploading software, etc. Copyright March 2003, Computer Dynamics, Inc. Warning Caution Page 20 All Rights Reserved MPAC-18 Manual...
  • Page 21: Serial Communication Ports

    The floppy and CD-ROM drives are located behind the cover on the right side of the unit. Access to these drives can be obtained by removal of three Phillips screws. Page 21 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 22: Networking

    The IP Address must be changed to a unique address. If it is not changed, conflicts could occur on your network. Copyright March 2003, Computer Dynamics, Inc. Comments Caution Page 22 All Rights Reserved MPAC-18 Manual...
  • Page 23: Bios Settings

    In the ADVANCED menu, select Installed OS. Change to NTER Enable Enable 3F8 / IRQ 4 2F8 / IRQ3 3E8 / IRQ 9 Disabled ECP / 378 / IRQ7 / DMA3 . In the Exit menu, select Exit Saving Changes. Page 23 All Rights Reserved MPAC-18 Manual...
  • Page 24: Diagnostics And Troubleshooting

    You are starting your system for the first time. You have changed the hardware attached to your system. The CMOS memory had lost power and the configuration information has been erased. Copyright March 2003, Computer Dynamics, Inc. press <F1> to RESUME Page 24 All Rights Reserved MPAC-18 Manual...
  • Page 25: Maintenance

    This should never be done, keys were unless you are attempting to pressed twice at the same reset the computer. time. A system floppy disk is Remove disk and cycle power. inserted. Page 25 All Rights Reserved MPAC-18 Manual Solution...
  • Page 26: External Ps/2 Mouse

    Use PS/2 compatible keyboard supported. Keyboard not plugged into Plug keyboard in. (Power down keyboard port on the computer. computer first.) System is busy. Press view task list. Page 26 All Rights Reserved MPAC-18 Manual Solution Solution Solution ELETE Solution ELETE...
  • Page 27: Network Communications

    If the self-test fails, the problem is printer-specific. The printing section of the software documentation and in Windows online Help may also be helpful. Page 27 All Rights Reserved MPAC-18 Manual Solution Solution...
  • Page 28: Figure 1. Front Plan View

    Figure 1. Front Plan View Figure 2. Bottom Plan View See the Appendix for I/O panel layout Page 28 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 29: Figure 3. Side Plan View

    Figure 3. Side Plan View Figure 4. Top Plan View Page 29 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 30: Figure 5. Back Plan View

    Figure 5. Back Plan View Page 30 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 31: Figure 6. Installation Diagram

    Figure 6. Installation Diagram Page 31 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 32: Specifications

    Computer Dynamics, Inc. Power 90 to 132VAC Single Phase Requirements Weight 46 lbs 19.11H x 24.07W x 11.49D inches Physical Dimensions Copyright March 2003, Computer Dynamics, Inc. Table 1 Unit Specifcations Page 32 All Rights Reserved MPAC-18 Manual...
  • Page 33: Vertical Connectors And Strapping Fields

    Acceleration with source and destination Transparent BLT, instant Full Screen Page Flip and read back of CRT Scan line counters. Advanced Power Management feature minimizes power usage with VESA Standards supported. Copyright March 2003, Computer Dynamics, Inc. Page 33 All Rights Reserved MPAC-18 Manual...
  • Page 34 Appendix I/O: Page 34 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 35: Figure 8. I/O Panel

    I/O Layout and Pinout Configuration Figure 8. I/O Panel. INSERT PICTURE AFTER FIRST BUILD Page 35 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 36: Table 3 Parallel (Lpt-1) Jack

    Busy in/out Paper End in/out Select Out Auto Feed XT in/out in/out Error in/out Initialize Printer Select In (from Printer) in/out in/out 18 to 25 Ground Page 36 All Rights Reserved MPAC-18 Manual Assignment Signal direction from computer...
  • Page 37: Table 4 Ethernet Jacks

    Ethernet Assignment Direction Con 1 Output Con 2 Input Function Pin A Pin B 120 V Pin C Pin D Pin E Function +5V fused Port 2 - Port 2 + Shell Shield Page 37 All Rights Reserved MPAC-18 Manual Output Input...
  • Page 38: Table 7 Serial Jack, Rs232 & Rs485

    (Transmit Data) (Data Terminal Ready) (Signal Ground) (Data Set Ready) (Request to Send) (Clear to Send) (Ring Indicator) Copyright March 2003, Computer Dynamics, Inc. RS485 Jack RS-232C Direction Name Page 38 All Rights Reserved MPAC-18 Manual DB9 Pin Assignment Direction...
  • Page 39: Additional Reading

    CDI is a wholly owned subsidiary of GE Fanuc. As such, references to GE Fanuc are made solely for legal purposes and all sales and support for this product will be maintained by Computer Dynamics, Inc, CDI hereafter, 7640 Pelham Road, Greenville SC 29615 ph:864-627-8800. Page 39 Copyright March 2003, Computer Dynamics, Inc. All Rights Reserved MPAC-18 Manual...
  • Page 40 CDI. Thank you. Name: Company: Address: Phone: Product Type: COMMENTS: Copyright March 2003, Computer Dynamics, Inc. Computer Dynamics, Inc. 7640 Pelham Rd. Greenville, S.C. 29615 Phone: (864) 627-8800 Page 40 All Rights Reserved MPAC-18 Manual Card Serial No.