FIXAIR Mini FXM36 User Manual

Bipolar ionization

Advertisement

Quick Links

Bipolar Ionization
USER`S MANUAL
FixAir Mini
Bipolar Ionization and UVC-UVA Sterilization Air Purifying System
FixAir In-Duct_MU
Versión: 1.04
ENGLISH

Advertisement

Table of Contents
loading

Summary of Contents for FIXAIR Mini FXM36

  • Page 1 Bipolar Ionization USER`S MANUAL FixAir Mini Bipolar Ionization and UVC-UVA Sterilization Air Purifying System FixAir In-Duct_MU Versión: 1.04 ENGLISH...
  • Page 2: Table Of Contents

    (VIRUSES AND BACTERIA). CLUSTERING. VOC’S (Volatile Organic Components). Main Components. Transport and Packaging. Installing. Starting Up. Carrying out Maintenance on the Device. Troubleshooting. 12.1 Replacing the quick flow fuse. Product Scope. WARRANTY. Page 2 of 17 FixAir In-Duct_MU Versión: 1.04 ENGLISH...
  • Page 3: General Information

    Danger to life is involved. Tab. 2: Symbols. Packaging Contents List. Inside the product packaging, you will find: One (1) User’s Manual. One (1) FixAir Mini device. One (1) Electrical cord. Page 3 of 17 FixAir In-Duct_MU Versión: 1.04...
  • Page 4: Technical Data

    * Subject to an adequate maintenance of the carbon fiber brushes. Air Cleaning Capacity Specifications. The air cleaning capacity of the FixAir models is given for the cooling capacity of the split-type units for which they are designed. The following table shows this relationship.
  • Page 5: Safety Instructions

    FixAir devices must never operate in rooms where there is risk of fire. FixAir devices are to be installed on top or under a cassette o minisplit type of air conditioning system. FixAir devices must not be operated in a corrosive atmosphere.
  • Page 6: Functional Description

    POLLUTANTS, MICROORGANISMS AND PATHOGENS (VIRUSES AND BACTERIA). FixAir ionization systems’ effectiveness in purifying the air lies in the capacity that the ions they generate have for reaching practically every surface and every corner inside the space the devices have been properly selected for.
  • Page 7: Clustering

    In the lung these particles irritate and corrode the alveolar wall, and consequently impair lung function. Bipolar ions generated by FixAir systems are attracted to the particles in the air attaching to them while they are suspended in the air or on surfaces;...
  • Page 8: Main Components

    Main Components. The device consists of the following components: Fig. 4: Components Page 8 of 17 FixAir In-Duct_MU Versión: 1.04 ENGLISH...
  • Page 9: Transport And Packaging

    Interrupter (GFCI) socket, or directly to the evaporrator unit of the air conditioner when installed in a cold room. To select the proper location for the instalation of your FixAir Room device, the following considerations must be taken into account:...
  • Page 10 Mini device, make sure to place it in the air suction line of the evaporator. The power cord supplied with your FixAir Mini device is 1,5 meters long. Fig. 5: Installation of the FixAir Mini device on a evaporator unit equipment of the minisplit or cassette device.
  • Page 11 5. Adjust the length of the connection cable by measuring the distance between the device connector and the connection terminal block (located inside) of the evaporator unit. Trim the cable to the desired length. Page 11 of 17 FixAir In-Duct_MU Versión: 1.04 ENGLISH...
  • Page 12 Connect the end of the cable with the male connector to the female connector. 8. Re-energize the 'split' type equipment from the distribution board. Press the on/off button. The device should start working immediately. Luces de encendido. Page 12 of 17 FixAir In-Duct_MU Versión: 1.04 ENGLISH...
  • Page 13: Starting Up

    Press the on/off button. Its LED lights will indicate that it is operating, and specifically that the ionizer(s) are operating. Carrying out Maintenance on the Device. FixAir strongly recommends the device be cleaned on a regular basis and at least twice a year, taking the following instructions into consideration: Caution, high voltage! Disconnect the device from the AC outlet.
  • Page 14 NOTICE: Always be careful never to touch the needlepoint brushes of the ionizers; there is a risk of electric shock. Tab. 5. Maintenance tasks. Page 14 of 17 FixAir In-Duct_MU Versión: 1.04 ENGLISH...
  • Page 15: Troubleshooting

    Replace the fuse and close the fuse holder by pressing and turning the cover with a Phillips screwdriver clockwise Fuse holder. motion. Img. 6. Replacing the quick blow fuse. Page 15 of 17 FixAir In-Duct_MU Versión: 1.04 ENGLISH...
  • Page 16: Product Scope

    Room’s continuous non stop operation brings bipolar ionization technology’s benefits into your own personal space. Easy to move around, our FixAir Home and Office solution is ideal for homes and spaces where people spend long periods of time and need a...
  • Page 17: Warranty

    (1) year warranty. After trying out your new FixAir product and verifying that it is functional, you will benefit from a one (1) yearlong product warranty, as follows: from the day of reception and during 12 months, all product quality problems will be covered, except those caused by human factors;...

This manual is also suitable for:

Mini fxm64

Table of Contents