FIXAIR FXR15 User Manual

Air ionization system

Advertisement

Quick Links

Air Ionization System
USER´S MANUAL
FixAir Room
FixAir Room_MU
Version: 1.05
ENGLISH

Advertisement

Table of Contents
loading

Summary of Contents for FIXAIR FXR15

  • Page 1 Air Ionization System USER´S MANUAL FixAir Room FixAir Room_MU Version: 1.05 ENGLISH...
  • Page 2: Table Of Contents

    (VIRUSES AND BACTERIA). CLUSTERING. VOC’S (Volatile Organic Components). Main Components. Transport and Packaging. Installing. Ceiling installation. Start-Up. Carrying out Maintenance on the Device. Troubleshooting. 12.1 Replacing the quick flow fuse. Product Scope. WARRANTY. Page 2 of 16 FixAir Room_MU Version: 1.05 ENGLISH...
  • Page 3: General Information

    Packaging Contents List. Inside the product packaging, you will find: One (1) User’s Manual. 2. One (1) Electrical cord. 3. One (1) FixAir Room device. 4. One (1) Drilling Template for Fixation Holes. Page 3 of 16 FixAir Room_MU Version: 1.05...
  • Page 4: Technical Data

    * Subject to an adequate maintenance of the needlepoint ionizer’s brushes. Air Cleaning Capacity Specifications. The air cleaning capacity of the FixAir models is given for standard and high air-loads such as in toilet facilities, laboratories, changing rooms, pathology areas, food storage rooms, cold storage rooms for meat/fish/- cheese, defrosting areas, ripening, or pickling rooms, and food processing rooms.
  • Page 5: Safety Instructions

    FixAir devices must never operate in rooms where there is risk of fire. FixAir devices are to be installed on the ceiling or wall of a room. FixAir devices must not be operated in a corrosive atmosphere.
  • Page 6: Functional Description

    POLLUTANTS, MICROORGANISMS AND PATHOGENS (VIRUSES AND BACTERIA). FixAir ionization systems’ effectiveness in purifying the air lies in the capacity that the ions they generate have for reaching practically every surface and every corner inside the space the devices have been properly selected for.
  • Page 7: Clustering

    In the lung these particles irritate and corrode the alveolar wall, and consequently impair lung function. Bipolar ions generated by FixAir systems are attracted to the particles in the air attaching to them while they are suspended in the air or on surfaces;...
  • Page 8: Main Components

    Main Components. The device consists of the following components: Fig. 4: Components. Page 8 of 16 FixAir Room_MU Version: 1.05 ENGLISH...
  • Page 9: Transport And Packaging

    To select the proper location for the instalation of your FixAir Room device, the following considerations must be taken into account: The maximum room size your FixAir Room device is suitable for must be in accordace with the indications provided in Table 3.
  • Page 10: Fixair Room_Mu

    To achieve a more homogeneous spread of the bipolar ions generated by your FixAir Room device, position it in the line of the air flowing out of the HVAC‘s grills or evaporator, but not to blocking the free flow of air.
  • Page 11: Ceiling Installation

    Ceiling installation. After having prepared the holes in the ceiling material or installation system (drywall for example), to fix your FixAir Room device to the ceiling follow these easy steps: Insert the electrical power cord in the device‘s socket (see figure 6.) without connecting it to the power source.
  • Page 12: Start-Up

    Identify the two (2) diagonally opposed holes on the black plate for ceiling installation. See figure 8. FXR30 FXR15 Fig. 8. Holes for ceiling installation. Present the body of the device over the holes on the ceiling making them match those on the back plate. Insert the screws and tighten them.
  • Page 13: Carrying Out Maintenance On The Device

    Air Ionization System Carrying out Maintenance on the Device. FixAir strongly recommends the device be cleaned on a regular basis and at least twice a year, taking the following instructions into consideration: Caution, high voltage! Disconnect the device from the AC outlet. To avoid an...
  • Page 14: Troubleshooting

    With the use of a phillips screwdriver open the short blow fuse casing by pressing and turning its cap with a counter clockwise motion. Img. 6. Replacing the quick blow fuse. Page 14 of 16 FixAir Nano_MU Version: 1.01 ENGLISH...
  • Page 15: Product Scope

    Room’s continuous non stop operation brings bipolar ionization technology’s benefits into your own personal space. Easy to move around, our FixAir Home and Office solution is ideal for homes and spaces where people spend long periods of time and need a...
  • Page 16: Warranty

    (1) year warranty. After trying out your new FixAir product and verifying that it is functional, you will benefit from a one (1) yearlong product warranty, as follows: from the day of reception and during 12 months, all product quality problems will be covered, except those caused by human factors;...

This manual is also suitable for:

Fxr15-iFxr30Fxr30-i