Page 1
Appendix A Technical Description Operating Instructions For the Front Panel Controller With IEEE-488, RS-232, or RS-422 Interface. Ophir RF Rev. H This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023 Rev: H...
Monitor Options ..........................18 INTERFACE PIN ASSIGNMENTS ................. 20 : GPIB (IEEE-488) C ....................20 ONNECTOR ONNECTOR : RS-232 S I/O ........................21 ONNECTOR ERIAL This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023 Rev: H...
Page 3
Table 4. User Configuration Mode and Status Displays..................... 10 Table 5. Amplifier Control Commands ........................12 Table 6. GPIB Commands ............................13 Table 7. Calibration Mode Displays ........................... 16 This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023 Rev: H...
– “Set VVA: xxx.x%”. The next button is the ALC button. If pressed, this button places the unit into the ALC mode – “Set ALC: xx.x dBm”. It also changes the display so This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023...
Up and Down F & G level when in the ALC mode. These buttons manipulate various Switches parameters depending on the operating mode of the amplifier. This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023 Rev: H...
Instructions 2. Adjust the desired output level or the gain using the Set ALC or Set VVA level function, respectively. This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023 Rev: H...
Many specific aspects of the display in Run Mode are dictated by settings made in the configuration menu. o Cycle through the front panel menu items by pressing the MODE key. This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023 Rev: H...
Ophir RF Technician for Max Rev: XXXX.X W safety purposes to protect the amplifier. If either setting is exceeded, a fault is generated. This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023 Rev: H...
Page 9
In Pwr displayed and this menu item is and/or VSWR and/or Mon x skipped. and/or ALC Range and/or EXT. VSWR This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023 Rev: H...
Ophir RF, depending on amplifier’s output power set by Ophir RF, Min. and Max. value level) to Maximum ALC value in dBm at startup. This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023 Rev: H...
User: Use the and buttons to change the VSWR Alarm level until it reads “Max VSWR: 5.0 dB”, then press the MODE button. Unit: Stores the information and returns to the main System Configuration menu. This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023 Rev: H...
Returns the current levels of all current and voltage monitors in the system. The reply will consist of a string that contains a single space (if no monitors have This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023...
(Up to 31 Characters). MODEL? Returns the Model Number of the Amplifier (Needs to be set first, by Ophir RF, for a return response). SERIAL? Returns the Serial Number of the Amplifier (Needs to be set first, by Ophir RF, for a return response).
(i.e., has the effect of issuing the ack_faults command). If a serial poll command was not used, the SRQ line is un-asserted via the *CLS command. This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023...
& & & & & & & Service Request Enable Register Set by *SRE xxx Read by *SRE? Figure 2. GPIB Status Reporting Structure This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023 Rev: H...
The information in the following section relates to specific technical aspects of the Front Panel Controller and its integration into the RF Power Amplifier that is beyond the scope of normal end-user operation. The information is provided for the purpose of completeness of documentation and is for reference only.
VVA levels must be calibrated. To perform the Forward Power calibration, the amplifier must be attached to an external RF power meter via a load, with a continuous wave input source to the amplifier. Also, the directional coupler must be configured for forward power calibration.
User: Use the and buttons to adjust the output power so that the power level read on the RF power meter is 27.0 dBm. Then press the ‘MODE’ button. Unit: Top line displays: “Using the and buttons, adjust the output power to match the level below, and press the ‘MODE’...
Page 19
Unit: Top line displays: “Using the and buttons, select the lower fault value for the input, and press the MODE button.” Second line displays: “Lower I2= 0.00” User: Press the ‘MODE’ button (no adjustment is required). This Document contains proprietary and confidential information of Ophir RF Inc. March 28, 2023 Rev: H...