4/5 tpa/gmt fuse alarm panel with bay alarms

Advertisement

Quick Links

Dual 200A 4/5 TPA/GMT
Fuse Alarm Panel with
Bay Alarms
Model 009-8005-1404 Installation Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Dual 200A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Amphenol Dual 200A

  • Page 1 Dual 200A 4/5 TPA/GMT Fuse Alarm Panel with Bay Alarms Model 009-8005-1404 Installation Guide...
  • Page 2 Amphenol Network Solutions assumes no liability from the application or use of these products. Amphenol Network Solutions does not convey any license under its patent rights nor the patent rights of others. This document and the products described herein are subject to change without notice.
  • Page 3: Table Of Contents

    Figure 10 – GMT Output Lug Connections ..................... 10 Figure 11 – Installing TPA Fuses ......................11 Figure 12 – Installing GMT Fuses ......................11 Figure 13 – Designation Card ........................ 12 Dual 200A 4/5 TPA/GMT Amphenol Network Solutions All rights reserved. 12.17.19 126152-6 Fuse Alarm Panel with 509.926.6000 –...
  • Page 4: Overview

    Immediately report any shipping damage, defects or missing parts to Amphenol Network Solutions at 509-926-6000. Keep all documentation that comes with your shipment. Amphenol Network Solutions is not liable for shipping damage. If the product is damaged, please notify the carrier and call Amphenol Network Solutions Customer Service at 509-926-6000 for further recourse.
  • Page 5: Specifications

    Torque supplied bolt (using 7/16 in. or 12 mm socket) to 4 ft-lb dual-hole compression lug (5.42 N•m) Ground wire size Up to #4 AWG (depends on input interrupt device) Dual 200A 4/5 TPA/GMT Amphenol Network Solutions All rights reserved. 12.17.19 126152-6 Fuse Alarm Panel with 509.926.6000 – amphenol-ns.com...
  • Page 6 ~14 lb. (~6 kg) Weight, shipping ~15 lb. (~7 kg) Environment: Specifications: Operating temperature range -10°C (14°F) to 55°C (131°F) Dual 200A 4/5 TPA/GMT Amphenol Network Solutions All rights reserved. 12.17.19 126152-6 Fuse Alarm Panel with 509.926.6000 – amphenol-ns.com Bay Alarms...
  • Page 7: Installation

    ALERT! Only use components and crimping tools approved by agencies or certifying bodies recognized in your country or region such as Underwriter’s Laboratories (UL), TUV, etc. Dual 200A 4/5 TPA/GMT Amphenol Network Solutions All rights reserved. 12.17.19 126152-6 Fuse Alarm Panel with 509.926.6000 –...
  • Page 8: Figure 4 - Ground Lug Connection

    12. Insulate lug barrels with UL94 V-0 rated heat shrink tubing. 13. Clean terminals and lugs with a nonabrasive, nonmetallic pad. 14. Amphenol Network Solutions recommends a light coating of antioxidant on lugs and input BATTERY and RETURN terminals before connecting input terminals on back of the panel, as shown in Figure 5.
  • Page 9: Figure 6 - Disengaging A Tpa Fuse Holder

    21. Repeat steps 17 through 20 to power up Side B. PWR ON A and PWR ON B must both be lit. Figure 8 – Alarm Terminals Dual 200A 4/5 TPA/GMT Amphenol Network Solutions All rights reserved. 12.17.19 126152-6 Fuse Alarm Panel with 509.926.6000 –...
  • Page 10: Figure 9 - Tpa Output Lug Connections

    25. Clean the panel terminals and lugs with a nonabrasive, nonmetallic pad. 26. Amphenol Network Solutions recommends a light coat of antioxidant on the lugs and output BATTERY and RETURN terminals before connecting lugs to the terminals, as shown in Figure 9. (NEC specifies only one lug and load at each output terminal.)
  • Page 11: Figure 11 - Installing Tpa Fuses

    Expect continuity (0Ω) between C and NC of each set of terminals • Expect an open circuit (∞Ω) between C and NO of each set of terminals Dual 200A 4/5 TPA/GMT Amphenol Network Solutions All rights reserved. 12.17.19 126152-6 Fuse Alarm Panel with 509.926.6000 –...
  • Page 12: Figure 13 - Designation Card

    Figure 13. Turn on equipment loads one at a time to verify proper operation of loads. Figure 13 – Designation Card Dual 200A 4/5 TPA/GMT Amphenol Network Solutions All rights reserved. 12.17.19 126152-6 Fuse Alarm Panel with 509.926.6000 – amphenol-ns.com...
  • Page 13: Accessories

    1.5 Accessories The following lists optional and replacement items for the panel. For compression lugs, please refer to Wire Sizing & Label Convention Chart (Amphenol Network Solutions Part No. 117995) included with your panel. Item Description Part Number PWR / FUSE / BAY ALARM LEDs & Contacts...
  • Page 14: Schematic Drawing

    BATT B TPA OUTPUT RTN B TPA FUSE HOLDER LEDS TPA OUTPUT BATT B INPUT B BATT Dual 200A 4/5 TPA/GMT Amphenol Network Solutions All rights reserved. 12.17.19 126152-6 Fuse Alarm Panel with 509.926.6000 – amphenol-ns.com Bay Alarms...
  • Page 15: Assembly Drawing

    EIA/WECO Mounting Patterns FRONT VIEW Amphenol Network Solutions assumes no liability from the application or use of these products. Neither does Amphenol Network Solutions convey any license under its patent rights or the patent rights of others. This document and the products described herein are subject to change without notice.