Download Print this page

Hydrogen For Health H2Life BGv4 User Manual

Brown's gas therapy machine

Advertisement

Brown's Gas Therapy Machine v4.0
H2Life BGv4
User's Manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the H2Life BGv4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hydrogen For Health H2Life BGv4

  • Page 1 Brown’s Gas Therapy Machine v4.0 H2Life BGv4 User’s Manual...
  • Page 2: Table Of Contents

    Table of contents Part List..............BG4 Machine Diagram........... Installation Manual..........Operation Instructions..........Troubleshooting............ Maintenance............Warranty............... Legal Disclaimer...........
  • Page 3: Part List

    Part List Cannula Stone Diffuser Brown’s Gas Therapy Machine Water Trap Bottle of Lye Measuring Spoon Collapsible Funnel Drain Hose Note This system requires Destillated Water to operate which is not included. This item is available in most grocery stores. Reverse osmosis water, tap water, bottled water or any other kind of water will not work.
  • Page 4 Diagram Lye Water Tank Relief Valve Water Level Tank Cap Bubbler Tank Screen Outlet Port Drain Port Drain Valve On/Off Button...
  • Page 5: Installation Manual

    Installation Manual Perform a visual inspection of the machine. Look for any damage that may have occurred during shipping. Contact us if there is any damage to the machine or to any of the accessories. Our contact information is at the end of this document. Open up the lye water tank cap, as shown below: Deposit two spoon-fulls of lye into the Lye Water Tank.
  • Page 6 Installation Manual Fill up the Lye Water Tank with distilled water using provided funnel. Be careful not to overflow the tank. Pay attention to the water level indicator. Fill up to just below the full line. Put Lye Water Tank cap back in place. Make sure to tighten well. Fill up Bubbler tank with distilled water by taking off...
  • Page 7 Screen Diagram Play/Pause button Add 30min Substract 10min Time Weight Indicator Bar Frequency Weight Temperature Maintenance Indicator Dim Screen...
  • Page 8: Operation Instructions

    Operation Instructions Click on the “Time” button to change to the desired operation time. Dial in your desired operation time. Click on “ok” to confirm change. Click on the “Weight” button to dial in your weight. Click on “ok” to confirm change.
  • Page 9 Operation Instructions Click on the “Frequency” button to set the desired frequency. Click “ok” to confirm changes. Start your inhalation session by pressing the play button.
  • Page 10 Operation Instructions Plug your choice of Nasal Cannula or Diffuser Stone into the outlet port as shown below: Note If diffuser stone is plugged in make sure to set the weight to 255lbs You may add 30min or subtract 10min by pressing the following buttons:...
  • Page 11 Operation Instructions Feel free to pause the operation at any time by pressing the pause button: Note Press the “Dim” button to turn off the screen and the machine’s internal lights. You may use this function when using the BG4 machine in dark environments or when sleeping.
  • Page 12: Troubleshooting

    Troubleshooting No bubbles forming inside the Bubbler Possible causes: - If you just turned on your BG4; it may take a couple minutes before you see any bubble formation. - The lye water tank cap might be loose. Be sure to tighten it firmly. No gas coming out of the cannula Possible causes: - If your BG4 has been constantly running for some time it may be in...
  • Page 13 Troubleshooting No gas coming out of the diffuser stone Possible cause: - The water trap might be plugged in. Disconnect the water trap and make sure your stone diffuser is plugged in directly to the outlet port. My BG4 machine is on but the screen is off Possible cause: - You may have accidently pressed the “Dim”...
  • Page 14: Maintenance

    Maintenance Perform the following everytime the Lye Water tank drops 1 to 2 inches below the full line: Perform a visual inspection of the lye water tank. If the water level indicator is down by more than an inch proceed to the following step. Take a recipient where you can store the bubbler’s water momentarily.
  • Page 15 Maintenance Fill up Bubbler tank with distilled water by taking off the tank’s cap. Make use of provided funnel. You may pull the tank’s valve up so the tank fills up quicker. Note Make sure the tank’s valve snaps back down. Put Bubbler Tank cap back in place.
  • Page 16 Maintenance Plug the drain hose to the drain port. Make sure that the end of the drain hose is pointing to the sink or a recipient. You may take the tank’s cap off so water flows down quicker. After the tank is completely drain press down on the silver part of the drain port to release the drain fitting.
  • Page 17 Maintenance Fill up the Lye Water Tank with distilled water using provided funnel. Be careful not to overflow the tank. Pay attention to the water level indicator. Fill up to just below the full line. Put Lye Water Tank cap back in place. Make sure to tighten well. Open the bubbler’s bottom valve to drain the bubbler's tank.
  • Page 18 Maintenance Fill up Bubbler tank with distilled water by taking off the tank’s cap. Make use of provided funnel. You may pull the tank’s valve up so the tank fills up quicker. Note Make sure the tank’s valve snaps back down. Put Bubbler Tank cap back in place.
  • Page 19: Warranty

    Warranty Thanks for purchasing our products at Hydrogen for Health operated by Dell Property LLC. In order to be eligible for a refund, you have to return the product within 60 calendar days of your purchase. The product must be in the same condition that you receive it and undamaged in any way.
  • Page 20: Legal Disclaimer

    Legal Disclaimer PRODUCT DISCLAIMER THE FOLLOWING TERMS AND CONDITIONS APPLY TO ALL SALES AND USES OF HYDROGEN4HEALTH PRODUCTS OR SERVICES. PLEASE REVIEW THESE TERMS CAREFULLY. THESE TERMS AND CONDITIONS INCLUDE LIMITED WARRANTIES, DISCLAIMERS OF LIABILITY, AND ARBITRATION PROVISIONS. KEEPING, USING, OR ALLOWING USE OF THE PRODUCT OR SERVICES INDICATES YOUR AGREEMENT TO THESE TERMS.
  • Page 21 Contact Us Address Orem, Utah, 84097 E-mail us info@hydrogen4health.com Skype us Steve Dell Youtube Delvis11 Facebook Hydrogen Water Health Working Hours Monday - Friday: 9am -6pm Weekends and Public Holidays: Closed...