CPA -0010-01009D01 User & Installation Manual

Standby ups

Advertisement

CPA-0010-01009D01 Standby UPS
1000VA Model
User & Installation Manual
www.cpa-ltd.net
| © 2021 CP Automation Ltd. All rights reserved. (Rev 02)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CPA-0010-01009D01 and is the answer not in the manual?

Questions and answers

Summary of Contents for CPA CPA-0010-01009D01

  • Page 1 CPA-0010-01009D01 Standby UPS 1000VA Model User & Installation Manual www.cpa-ltd.net | © 2021 CP Automation Ltd. All rights reserved. (Rev 02)
  • Page 2 CPA-0010-01009D01 User’s Manual Uninterruptible Power Supply Table of Contents Installation and Operation………………………………………………………………………. Product Overview……………………………………………………………………………………. LED lndicators………………………………………………………………………………………………. Safety Precautions………………………………………………………………………………………….. Troubleshooting…………………………………………………………………………………………………… Specifications…………………………………………………………………………………………………………. Obtaining Service…………………………………………………………………………………………… Page 2...
  • Page 3 CPA-0010-01009D01 User’s Manual Uninterruptible Power Supply Installation and Operation Inspection The following items are inside the box: • UPS unit • User manual Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, re-pack the unit and return it to the place of purchase.
  • Page 4 CPA-0010-01009D01 User’s Manual Uninterruptible Power Supply Connect Com. Port and Install Software (Only for models with a USB port) Connect one end of the USB cable to PC and the other to the USB port at the rear of the UPS.
  • Page 5 CPA-0010-01009D01 User’s Manual Uninterruptible Power Supply SAFETY PRECAUTIONS • This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts. Only factory service personnel may perform repairs. • This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen.
  • Page 6 CPA-0010-01009D01 User’s Manual Uninterruptible Power Supply • Do not dispose of batteries in a fire as they may explode. • Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorised personnel away from batteries.
  • Page 7 CPA-0010-01009D01 User’s Manual Uninterruptible Power Supply Specifications CPA-0010-01009D01 MODEL NUMBER CAPACITY Power rating 1000VA/600W Voltage 220/230/240VAC INPUT Frequency 50/60Hz auto-sensing Voltage 220/230/240VAC OUTPUT Waveform Simulated sine wave Frequency 50/60 Hz ± 1Hz Transfer time 6ms typical Battery type Sealed, maintenance free lead acid...

Table of Contents